Literature DB >> 18683280

Development and validation of a smoothing-splines-based correction method for improving the analysis of CEST-MR images.

J Stancanello1, E Terreno, D Delli Castelli, C Cabella, F Uggeri, S Aime.   

Abstract

Chemical exchange saturation transfer (CEST) imaging is an emerging MRI technique relying on the use of endogenous or exogenous molecules containing exchangeable proton pools. The heterogeneity of the water resonance frequency offset plays a key role in the occurrence of artifacts in CEST-MR images. To limit this drawback, a new smoothing-splines-based method for fitting and correcting Z-spectra in order to compensate for low signal-to-noise ratio (SNR) without any a priori model was developed. Global and local voxel-by-voxel Z-spectra were interpolated by smoothing splines with smoothing terms aimed at suppressing noise. Thus, a map of the water frequency offset ('zero' map) was used to correctly calculate the saturation transfer (ST) for each voxel. Simulations were performed to compare the method to polynomials and zero-only-corrected splines on the basis of SNR improvement. In vitro acquisitions of capillaries containing solutions of LIPOCEST agents at different concentrations were performed to experimentally validate the results from simulations. Additionally, ex vivo investigations of bovine muscle mass injected with LIPOCEST agents were performed as a function of increasing pulse power. The results from simulations and experiments highlighted the importance of a proper 'zero' correction (15% decrease of fictitious CEST signal in phantoms and ex vivo preparations) and proved the method to be more accurate compared with the previously published ones, often providing a SNR higher than 5 in different simulated and experimentally noisy conditions. In conclusion, the proposed method offers an accurate tool in CEST investigation. Copyright (c) 2008 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2008        PMID: 18683280     DOI: 10.1002/cmmi.240

Source DB:  PubMed          Journal:  Contrast Media Mol Imaging        ISSN: 1555-4309            Impact factor:   3.161


  43 in total

1.  Design and testing of paramagnetic liposome-based CEST agents for MRI visualization of payload release on pH-induced and ultrasound stimulation.

Authors:  Daniela Delli Castelli; Cinzia Boffa; Pierangela Giustetto; Enzo Terreno; Silvio Aime
Journal:  J Biol Inorg Chem       Date:  2013-09-14       Impact factor: 3.358

2.  Assessment of frequency drift on CEST MRI and dynamic correction: application to gagCEST at 7 T.

Authors:  Johannes Windschuh; Moritz Zaiss; Philipp Ehses; Jae-Seung Lee; Alexej Jerschow; Ravinder R Regatte
Journal:  Magn Reson Med       Date:  2018-05-31       Impact factor: 4.668

3.  Accuracy and uncertainty of asymmetric magnetization transfer ratio quantification for amide proton transfer (APT) imaging at 3T: a Monte Carlo study.

Authors:  Jing Yuan; Qinwei Zhang; Yi-Xiang Wang; Juan Wei; Jinyuan Zhou
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2013

4.  Chemical exchange saturation transfer magnetic resonance imaging of human knee cartilage at 3 T and 7 T.

Authors:  Anup Singh; Mohammad Haris; Kejia Cai; Victor B Kassey; Feliks Kogan; Damodar Reddy; Hari Hariharan; Ravinder Reddy
Journal:  Magn Reson Med       Date:  2011-12-27       Impact factor: 4.668

5.  CEST phase mapping using a length and offset varied saturation (LOVARS) scheme.

Authors:  Xiaolei Song; Assaf A Gilad; Suresh Joel; Guanshu Liu; Amnon Bar-Shir; Yajie Liang; Michael Gorelik; James J Pekar; Peter C M van Zijl; Jeff W M Bulte; Michael T McMahon
Journal:  Magn Reson Med       Date:  2012-01-13       Impact factor: 4.668

6.  Evaluations of Tumor Acidosis Within In Vivo Tumor Models Using Parametric Maps Generated with Acido CEST MRI.

Authors:  Liu Qi Chen; Edward A Randtke; Kyle M Jones; Brianna F Moon; Christine M Howison; Mark D Pagel
Journal:  Mol Imaging Biol       Date:  2015-08       Impact factor: 3.488

7.  Evaluations of extracellular pH within in vivo tumors using acidoCEST MRI.

Authors:  Liu Qi Chen; Christine M Howison; Justin J Jeffery; Ian F Robey; Phillip H Kuo; Mark D Pagel
Journal:  Magn Reson Med       Date:  2013-11-26       Impact factor: 4.668

Review 8.  Magnetization Transfer Contrast and Chemical Exchange Saturation Transfer MRI. Features and analysis of the field-dependent saturation spectrum.

Authors:  Peter C M van Zijl; Wilfred W Lam; Jiadi Xu; Linda Knutsson; Greg J Stanisz
Journal:  Neuroimage       Date:  2017-04-21       Impact factor: 6.556

9.  Tracking the relative in vivo pharmacokinetics of nanoparticles with PARACEST MRI.

Authors:  M Meser Ali; Byunghee Yoo; Mark D Pagel
Journal:  Mol Pharm       Date:  2009 Sep-Oct       Impact factor: 4.939

10.  Using two chemical exchange saturation transfer magnetic resonance imaging contrast agents for molecular imaging studies.

Authors:  M Meser Ali; Guanshu Liu; Tejas Shah; Chris A Flask; Mark D Pagel
Journal:  Acc Chem Res       Date:  2009-07-21       Impact factor: 22.384

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.