Literature DB >> 8756927

Multiphasic renal CT: comparison of renal mass enhancement during the corticomedullary and nephrographic phases.

B A Birnbaum1, J E Jacobs, P Ramchandani.   

Abstract

PURPOSE: To evaluate thin-section computed tomography (CT) performed during the corticomedullary and nephrographic phases of contrast material enhancement in the characterization of renal masses.
MATERIALS AND METHODS: A prospective study of 30 patients was undertaken with CT to characterize 31 "indeterminate" renal masses. In all patients, 5-mm-thick, contiguous, high-tube-current (320-340-mA) scans were obtained through the kidneys before (axial mode), during (helical mode, 25-second delay, corticomedullary-phase images), and after (axial mode, 120-second delay, nephrographic-phase images) administration of a 117-second biphasic injection of intravenous contrast material.
RESULTS: Eight of 16 neoplasms measured less than 20 HU on CT scans obtained without contrast material enhancement; measurements of two of these corresponded to "cyst attenuation" during the corticomedullary phase. Enhancement of 10 HU or greater was demonstrated in 11 neoplasms during the corticomedullary phase and in all neoplasms in the nephrographic phase. No enhancement was seen in 15 radiologically benign cysts. Both renal neoplasms and normal renal cortex demonstrated significantly greater enhancement in the nephrographic phase compared with that in the corticomedullary phase (P = .0002 and P < .0001, respectively).
CONCLUSION: Enhancement of renal neoplasms is time dependent and may not be evident in hypovascular tumors analyzed during the early corticomedullary phase. Reliance on absolute CT attenuation measurements, without use of internal standards as controls, may lead to misdiagnosis of neoplasms as cysts.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8756927     DOI: 10.1148/radiology.200.3.8756927

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  19 in total

Review 1.  [Multidetector computed tomography (MDCT) of the kidneys].

Authors:  A J Ruppert-Kohlmayr; M M Uggowitzer
Journal:  Radiologe       Date:  2005-10       Impact factor: 0.635

2.  Renal cyst pseudoenhancement at multidetector CT: what are the effects of number of detectors and peak tube voltage?

Authors:  Zhen J Wang; Fergus V Coakley; Yanjun Fu; Bonnie N Joe; Sven Prevrhal; Luis A Landeras; Emma M Webb; Benjamin M Yeh
Journal:  Radiology       Date:  2008-07-15       Impact factor: 11.105

Review 3.  Dual energy CT: preliminary observations and potential clinical applications in the abdomen.

Authors:  Anno Graser; Thorsten R C Johnson; Hersh Chandarana; Michael Macari
Journal:  Eur Radiol       Date:  2008-08-02       Impact factor: 5.315

Review 4.  Dual energy MDCT assessment of renal lesions: an overview.

Authors:  Achille Mileto; Daniele Marin; Rendon C Nelson; Giorgio Ascenti; Daniel T Boll
Journal:  Eur Radiol       Date:  2013-10-04       Impact factor: 5.315

5.  Comparison of post contrast CT urography phases in bladder cancer detection.

Authors:  Malin Helenius; Par Dahlman; Maria Lonnemark; Einar Brekkan; Lisa Wernroth; Anders Magnusson
Journal:  Eur Radiol       Date:  2015-05-24       Impact factor: 5.315

6.  Examining the upper urinary tract in patients with hematuria-time to revise the CT urography protocol?

Authors:  Erik Rud; Kristina Flor Galtung; Peter Mæhre Lauritzen; Eduard Baco; Tove Flatabø; Gunnar Sandbæk
Journal:  Eur Radiol       Date:  2019-11-20       Impact factor: 5.315

7.  Advances of multidetector computed tomography in the characterization and staging of renal cell carcinoma.

Authors:  Athina C Tsili; Maria I Argyropoulou
Journal:  World J Radiol       Date:  2015-06-28

Review 8.  [Imaging renal cell carcinoma].

Authors:  A Graser; C J Zech; C G Stief; M F Reiser; M Staehler
Journal:  Urologe A       Date:  2009-04       Impact factor: 0.639

9.  Distinguishing enhancing from nonenhancing renal masses with dual-source dual-energy CT: iodine quantification versus standard enhancement measurements.

Authors:  Giorgio Ascenti; Achille Mileto; Bernhard Krauss; Michele Gaeta; Alfredo Blandino; Emanuele Scribano; Nicola Settineri; Silvio Mazziotti
Journal:  Eur Radiol       Date:  2013-03-12       Impact factor: 5.315

Review 10.  Multidetector CT urography in imaging of the urinary tract in patients with hematuria.

Authors:  Michael M Maher; Mannudeep K Kalra; Stefania Rizzo; Peter R Mueller; Sanjay Saini
Journal:  Korean J Radiol       Date:  2004 Jan-Mar       Impact factor: 3.500

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.