Spatial distribution of RF-induced E-fields and implant heating in MRI.

Peter Nordbeck1, Florian Fidler, Ingo Weiss, Marcus Warmuth, Michael T Friedrich, Philipp Ehses, Wolfgang Geistert, Oliver Ritter, Peter M Jakob, Mark E Ladd, Harald H Quick, Wolfgang R Bauer.   

Abstract

The purpose of this study was to assess the distribution of RF-induced E-fields inside a gel-filled phantom of the human head and torso and compare the results with the RF-induced temperature rise at the tip of a straight conductive implant, specifically examining the dependence of the temperature rise on the position of the implant inside the gel. MRI experiments were performed in two different 1.5T MR systems of the same manufacturer. E-field distribution inside the liquid was assessed using a custom measurement system. The temperature rise at the implant tip was measured in various implant positions and orientations using fluoroptic thermometry. The results show that local E-field strength in the direction of the implant is a critical factor in RF-related tissue heating. The actual E-field distribution, which is dependent on phantom/body properties and the MR-system employed, must be considered when assessing the effects of RF power deposition in implant safety investigations. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2008        PMID: 18666101     DOI: 10.1002/mrm.21475

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  35 in total

1.  It's the little things: On the complexity of planar electrode heating in MRI.

Authors:  Johannes B Erhardt; Thomas Lottner; Jessica Martinez; Ali C Özen; Martin Schuettler; Thomas Stieglitz; Daniel B Ennis; Michael Bock
Journal:  Neuroimage       Date:  2019-03-29       Impact factor: 6.556

2.  Parallel transmit excitation at 1.5 T based on the minimization of a driving function for device heating.

Authors:  N Gudino; M Sonmez; Z Yao; T Baig; S Nielles-Vallespin; A Z Faranesh; R J Lederman; M Martens; R S Balaban; M S Hansen; M A Griswold
Journal:  Med Phys       Date:  2015-01       Impact factor: 4.071

3.  3-T MRI safety assessments of magnetic dental attachments and castable magnetic alloys.

Authors:  M Hasegawa; K Miyata; Y Abe; T Ishii; T Ishigami; K Ohtani; E Nagai; T Ohyama; Y Umekawa; S Nakabayashi
Journal:  Dentomaxillofac Radiol       Date:  2015-03-18       Impact factor: 2.419

4.  Radiofrequency heating of metallic dental devices during 3.0 T MRI.

Authors:  M Hasegawa; K Miyata; Y Abe; T Ishigami
Journal:  Dentomaxillofac Radiol       Date:  2013-03-21       Impact factor: 2.419

5.  Ensuring safety of implanted devices under MRI using reversed RF polarization.

Authors:  William R Overall; John M Pauly; Pascal P Stang; Greig C Scott
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

6.  An RF-induced voltage sensor for investigating pacemaker safety in MRI.

Authors:  Thérèse Barbier; Roberto Piumatti; Bertrand Hecker; Freddy Odille; Jacques Felblinger; Cédric Pasquier
Journal:  MAGMA       Date:  2014-03-15       Impact factor: 2.310

7.  An optically coupled sensor for the measurement of currents induced by MRI gradient fields into endocardial leads.

Authors:  Eugenio Mattei; Federica Censi; Michele Triventi; Antonio Napolitano; Elisabetta Genovese; Vittorio Cannatà; Giovanni Calcagnini
Journal:  MAGMA       Date:  2014-10-11       Impact factor: 2.310

8.  MRI Conditional Actively Tracked Metallic Electrophysiology Catheters and Guidewires With Miniature Tethered Radio-Frequency Traps: Theory, Design, and Validation.

Authors:  Akbar Alipour; Eric S Meyer; Charles L Dumoulin; Ronald D Watkins; Hassan Elahi; Wolfgang Loew; Jeffrey Schweitzer; Gregory Olson; Yue Chen; Susumu Tao; Michael Guttman; Aravindan Kolandaivelu; Henry R Halperin; Ehud J Schmidt
Journal:  IEEE Trans Biomed Eng       Date:  2019-09-13       Impact factor: 4.538

Review 9.  Interventional CMR: Clinical applications and future directions.

Authors:  Toby Rogers; Robert J Lederman
Journal:  Curr Cardiol Rep       Date:  2015-05       Impact factor: 2.931

10.  Risk assessment of copper-containing contraceptives: the impact for women with implanted intrauterine devices during clinical MRI and CT examinations.

Authors:  Wiebke Neumann; Tanja Uhrig; Matthias Malzacher; Verena Kossmann; Lothar R Schad; Frank G Zoellner
Journal:  Eur Radiol       Date:  2018-11-19       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.