Literature DB >> 3261552

[Non-invasive versus invasive cardiovascular monitoring. Determination of stroke volume and pulmonary hydration using a new bioimpedance monitor].

J Boldt1, D Kling, A Thiel, G Hempelmann.   

Abstract

Measurement of hemodynamic parameters by noninvasive techniques is gaining more and more popularity in the face of severe complications associated with invasive methods. Thoracic electrical bioimpedance is a noninvasive means of estimating cardiac output (CO) and pulmonary edema formation. The validity of this method, however, has been controversial. In the present study a new bioimpedance monitoring system (NCCOM 3) was used in 10 intensive care patients undergoing mechanical hemofiltration (group I) and in 20 cardiac surgery patients undergoing either aortic valve replacement (AVR, group IIa, n = 10) or aorto-coronary bypass grafting (CABG, group IIb, n = 10). In cardiac surgery patients the measurements were performed before as well as after extracorporeal circulation (ECC). CO measured by the impedance monitor was compared to the standard thermodilution method; pulmonary fluids were estimated by a thermo-dye technique and by measurement of total electrical impedance (base impedance), expressed as the thoracic fluid index (TFI). The principal finding of the study was that CO as measured by the two techniques differed significantly in all groups with regard to absolute values. The relative changes in CO, however, were comparable in both intensive care patients and CABG patients. In patients with special thoracic blood flow conditions (regurgitation in aortic insufficiency patients), no corresponding course of CO could be found.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1988        PMID: 3261552

Source DB:  PubMed          Journal:  Anaesthesist        ISSN: 0003-2417            Impact factor:   1.041


  5 in total

1.  A comparison of the cardiovascular effects of phenylpropanolamine and phenylephrine containing proprietary cold remedies.

Authors:  S H Thomas; K L Clark; R Allen; S E Smith
Journal:  Br J Clin Pharmacol       Date:  1991-12       Impact factor: 4.335

2.  Continuous, non-invasive techniques to determine cardiac output in children after cardiac surgery: evaluation of transesophageal Doppler and electric velocimetry.

Authors:  Stephan Schubert; Thomas Schmitz; Markus Weiss; Nicole Nagdyman; Michael Huebler; Vladimir Alexi-Meskishvili; Felix Berger; Brigitte Stiller
Journal:  J Clin Monit Comput       Date:  2008-07-30       Impact factor: 2.502

3.  Multicenter evaluation of noninvasive cardiac output measurement by bioreactance technique.

Authors:  Nirav Y Raval; Pierre Squara; Michael Cleman; Kishore Yalamanchili; Michael Winklmaier; Daniel Burkhoff
Journal:  J Clin Monit Comput       Date:  2008-03-14       Impact factor: 2.502

4.  Impedance cardiography using the Sramek-Bernstein method: accuracy and variability at rest and during exercise.

Authors:  S H Thomas
Journal:  Br J Clin Pharmacol       Date:  1992-12       Impact factor: 4.335

Review 5.  Clinical review: hemodynamic monitoring in the intensive care unit.

Authors:  Joachim Boldt
Journal:  Crit Care       Date:  2002-01-11       Impact factor: 9.097

  5 in total