Literature DB >> 21271327

Performance of a fluorescence camera for detection of occlusal caries in vitro.

Anahita Jablonski-Momeni1, Helge Marten Schipper2, Simon Martin Rosen3, Monika Heinzel-Gutenbrunner3, Matthias Johannes Roggendorf2, Richard Stoll2, Vitus Stachniss2, Klaus Pieper3.   

Abstract

The aim of this study was to assess inter- and intra-examiner reproducibility and accuracy in the detection and assessment of occlusal caries in extracted human teeth using the newly developed fluorescence based camera VistaProof. Serial sectioning and microscopy are considered the gold standard. The occlusal surfaces of 53 teeth (99 investigation sites) were examined by two examiners with different levels of experience in cariology (one experienced dentist, one final-year dental student) and the VistaProof. Thereafter, the teeth were serially sectioned and assessed for lesion depth. The intraclass correlation coefficients for inter- and intra-examiner reproducibility for the fluorescence-based examinations were 0.76-0.95. There was a significant correlation between the fluorescence and histological examinations for both examiners (r (s) = 0.47 and 0.55, P < 0.01). At the D₁ diagnostic threshold (enamel and dentin lesions), sensitivity was 0.71-0.86 and specificity was between 0.32 and 0.76 at different cutoff values. At the D₃ diagnostic threshold (dentin lesions), sensitivity was 0.04-0.91 and specificity was 0.56-0.99 for both examiners. When the areas under the receiver-operating characteristic curves were compared, there was no significant difference in the performance between the examiners (P = 0.52 at the D₁ threshold, P = 0.81 at the D₃ threshold). The VistaProof demonstrated high reproducibility and good diagnostic performance for the detection of occlusal caries at various stages of the disease process. Novice and experienced examiners were able to apply this system as a supportive device for caries diagnostic and monitoring purposes. Sensitivity and specificity values varied depending on the cutoff values.

Entities:  

Mesh:

Year:  2011        PMID: 21271327     DOI: 10.1007/s10266-010-0139-y

Source DB:  PubMed          Journal:  Odontology        ISSN: 1618-1247            Impact factor:   2.634


  34 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

2.  Correlation between fissure discoloration, Diagnodent measurements, and caries depth: an in vitro study.

Authors:  Paola Francescut; Adrian Lussi
Journal:  Pediatr Dent       Date:  2003 Nov-Dec       Impact factor: 1.874

Review 3.  A systematic review of the performance of a laser fluorescence device for detecting caries.

Authors:  James D Bader; Dan A Shugars
Journal:  J Am Dent Assoc       Date:  2004-10       Impact factor: 3.634

4.  Influence of professional cleaning and drying of occlusal surfaces on laser fluorescence in vivo.

Authors:  A Lussi; C Longbottom; M Gygax; F Braig
Journal:  Caries Res       Date:  2005 Jul-Aug       Impact factor: 4.056

Review 5.  Measuring the accuracy of diagnostic systems.

Authors:  J A Swets
Journal:  Science       Date:  1988-06-03       Impact factor: 47.728

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

7.  A method of comparing the areas under receiver operating characteristic curves derived from the same cases.

Authors:  J A Hanley; B J McNeil
Journal:  Radiology       Date:  1983-09       Impact factor: 11.105

8.  Performance and reproducibility of a laser fluorescence system for detection of occlusal caries in vitro.

Authors:  A Lussi; S Imwinkelried; N Pitts; C Longbottom; E Reich
Journal:  Caries Res       Date:  1999 Jul-Aug       Impact factor: 4.056

9.  Clinical evaluation of visual, radiographic, and laser fluorescence methods for detection of occlusal caries.

Authors:  Roswitha Heinrich-Weltzien; Karin L Weerheijm; Jan Kühnisch; Thomas Oehme; Lutz Stösser
Journal:  ASDC J Dent Child       Date:  2002 May-Aug

Review 10.  Caries detection and diagnosis: novel technologies.

Authors:  Iain A Pretty
Journal:  J Dent       Date:  2006-08-09       Impact factor: 4.379

View more
  13 in total

1.  Performance of a new fluorescence camera for detection of occlusal caries in vitro.

Authors:  Anahita Jablonski-Momeni; Fabian Liebegall; Richard Stoll; Monika Heinzel-Gutenbrunner; Klaus Pieper
Journal:  Lasers Med Sci       Date:  2012-03-21       Impact factor: 3.161

2.  The use of computer-assisted FACE for minimal-invasive caries excavation.

Authors:  Philip Ganter; Ali Al-Ahmad; Karl-Thomas Wrbas; Elmar Hellwig; Markus Jörg Altenburger
Journal:  Clin Oral Investig       Date:  2013-07-05       Impact factor: 3.573

3.  In vivo assessment of caries excavation with a fluorescence camera compared to direct bacteriological sampling and quantitative analysis using flow cytometry.

Authors:  Richard Stoll; Beata Urban-Klein; Paul Giacomin; Alex Loukas; Anahita Jablonski-Momeni
Journal:  Lasers Med Sci       Date:  2013-10-19       Impact factor: 3.161

4.  Efficacy of the self-assembling peptide P11-4 in constructing a remineralization scaffold on artificially-induced enamel lesions on smooth surfaces.

Authors:  A Jablonski-Momeni; M Heinzel-Gutenbrunner
Journal:  J Orofac Orthop       Date:  2014-05-15       Impact factor: 1.938

5.  Traditional and novel methods for occlusal caries detection: performance on primary teeth.

Authors:  J F Souza; T Boldieri; M B Diniz; J A Rodrigues; A Lussi; R C L Cordeiro
Journal:  Lasers Med Sci       Date:  2012-07-06       Impact factor: 3.161

6.  In vivo performance of the VistaProof fluorescence-based camera for detection of occlusal lesions.

Authors:  Anahita Jablonski-Momeni; Monika Heinzel-Gutenbrunner; Sarah Marie Christine Klein
Journal:  Clin Oral Investig       Date:  2013-11-28       Impact factor: 3.573

7.  Objective identification of dental abnormalities with multispectral fluorescence imaging.

Authors:  Surya Pratap Singh; Pauli Fält; Ishan Barman; Arto Koistinen; Ramachandra Rao Dasari; Arja M Kullaa
Journal:  J Biophotonics       Date:  2016-12-12       Impact factor: 3.207

8.  Caries diagnosis using light fluorescence devices in comparison with traditional visual and tactile evaluation: a prospective study in 152 patients.

Authors:  María Melo; Agustín Pascual; Isabel Camps; Ángel Del Campo; Javier Ata-Ali
Journal:  Odontology       Date:  2016-09-21       Impact factor: 2.634

9.  Evaluation of a new fluorescence-based device in the detection of incipient occlusal caries lesions.

Authors:  Eva-Eleni Achilleos; Christos Rahiotis; Afrodite Kakaboura; George Vougiouklakis
Journal:  Lasers Med Sci       Date:  2012-05-11       Impact factor: 3.161

10.  Use of ICDAS-II, Fluorescence-Based Methods, and Radiography in Detection and Treatment Decision of Occlusal Caries Lesions: An In Vitro Study.

Authors:  Anahita Jablonski-Momeni; Jasmin Stucke; Torben Steinberg; Monika Heinzel-Gutenbrunner
Journal:  Int J Dent       Date:  2012-08-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.