Literature DB >> 19655179

Relationship between DIAGNOdent values and sealant penetration depth on occlusal fissures.

Jonas A Rodrigues1, Michele B Diniz, Isabel Hug, Rita C L Cordeiro, Adrian Lussi.   

Abstract

The aim of this in vitro study was to evaluate the relationship between laser fluorescence values and sealant penetration depth on occlusal fissures. One hundred and sixty-six permanent molars were selected and divided into four groups, which were each treated using a different sealant (two clear and two opaque). The teeth were independently measured twice by two experienced dentists using two laser fluorescence devices-DIAGNOdent (LF and LFpen)-before and after sealing, and then thermoclycled. After measuring, the teeth were histologically prepared and assessed for caries extension. Digital photographs of the cut sealed sites were assessed, and the sealant penetration depth was measured. All 166 sites were measured by one of the examiners taking as limits the outer and inner surface of the sealant into the fissure. For each device (LF and LFpen) and each group, the difference between the values at baseline and after sealing was plotted against the sealant penetration depth and scatter plots were provided. It could be observed that most of the points were concentrated around the zero line, for both LF and LFpen in the four groups. In conclusion, there is no relation between changes in DIAGNOdent values and increasing of depth sealant penetration within the occlusal fissures.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19655179     DOI: 10.1007/s00784-009-0321-1

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  24 in total

Review 1.  A systematic review of the performance of a laser fluorescence device for detecting caries.

Authors:  James D Bader; Dan A Shugars
Journal:  J Am Dent Assoc       Date:  2004-10       Impact factor: 3.634

2.  Retention and effectiveness of dental sealant after 15 years.

Authors:  R J Simonsen
Journal:  J Am Dent Assoc       Date:  1991-10       Impact factor: 3.634

3.  Retention of three fissure sealant resins. The effects of etching agent and curing method. Results over 3 years.

Authors:  W P Rock; S Weatherill; R J Anderson
Journal:  Br Dent J       Date:  1990-04-21       Impact factor: 1.626

4.  Ultraconservative and cariostatic sealed restorations: results at year 10.

Authors:  E J Mertz-Fairhurst; J W Curtis; J W Ergle; F A Rueggeberg; S M Adair
Journal:  J Am Dent Assoc       Date:  1998-01       Impact factor: 3.634

5.  Dental plaque and caries on occlusal surfaces of first permanent molars in relation to stage of eruption.

Authors:  J C Carvalho; K R Ekstrand; A Thylstrup
Journal:  J Dent Res       Date:  1989-05       Impact factor: 6.116

Review 6.  Pit and fissure sealants: another major cornerstone in preventive dentistry.

Authors:  D J Manton; L B Messer
Journal:  Aust Dent J       Date:  1995-02       Impact factor: 2.291

7.  Comparison between visual examination and a laser fluorescence system for in vivo diagnosis of occlusal caries.

Authors:  E C Sheehy; S R Brailsford; E A Kidd; D Beighton; L Zoitopoulos
Journal:  Caries Res       Date:  2001 Nov-Dec       Impact factor: 4.056

8.  Performance and reproducibility of a laser fluorescence system for detection of occlusal caries in vitro.

Authors:  A Lussi; S Imwinkelried; N Pitts; C Longbottom; E Reich
Journal:  Caries Res       Date:  1999 Jul-Aug       Impact factor: 4.056

9.  Effect of placing a clear sealant on the validity and reproducibility of occlusal caries detection by a laser fluorescence device: an in vitro study.

Authors:  C Deery; J Iloya; Z J Nugent; V Srinivasan
Journal:  Caries Res       Date:  2006       Impact factor: 4.056

10.  Fluoride in enamel lining pits and fissures of the occlusal groove-fossa system in human molar teeth.

Authors:  E Pearce; M Larsen; G Coote
Journal:  Caries Res       Date:  1999 May-Jun       Impact factor: 4.056

View more
  2 in total

1.  In vivo effectiveness of enamel sealants around orthodontic brackets.

Authors:  T E Bechtold; A Sobiegalla; M Markovic; M Berneburg; G R Göz
Journal:  J Orofac Orthop       Date:  2013-10-26       Impact factor: 1.938

2.  The effects of opaque and clear pit and fissure sealants on infrared laser fluorescence measurements.

Authors:  Z Bahrololoomi; M Khodabakhsh; Y Khaksar
Journal:  J Dent (Shiraz)       Date:  2014-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.