Lukla Biasi1, Tahir Ali, Robert Hinchliffe, Rob Morgan, Ian Loftus, Matt Thompson.
Abstract
Reintervention following endovascular aneurysm repair (EVAR) is required in up to 10% of patients at 30 days and is associated with a demonstrable risk of increased mortality. Completion angiography cannot detect all graft-related anomalies and computed tomographic angiography is therefore mandatory to ensure clinical success. Intraoperative angiographic computed tomography (DynaCT; Siemens, Germany) utilizes cone beam reconstruction software and flat-panel detectors to generate CT-like images from rotational angiographic acquisitions. We report the intraoperative use of this novel technology in detecting and immediately treating a proximal anterior type Ia endoleak, following an endovascular abdominal aortic repair, which was not seen on completion angiography. Immediate evaluation of cross-sectional imaging following endograft deployment may allow for on-table correction of clinically significant stent-related complications. This should both improve technical success and minimize the need for early secondary intervention following EVAR.Entities:
Mesh:
Year: 2008 PMID: 18661173 DOI: 10.1007/s00270-008-9399-0