Literature DB >> 21326529

Management of Endoleaks following Endovascular Aneurysm Repair.

Sarah B White1, S William Stavropoulos.   

Abstract

Endovascular aneurysm repair (EVAR) has emerged as a viable alternative to open repair for abdominal aortic aneurysms. Endoleaks are a complication unique to EVAR and can occur in up to 25% of patients. In this article, the management of endoleaks following EVAR will be discussed.

Entities:  

Keywords:  Endovascular aneurysm repair (EVAR); embolization; endoleak

Year:  2009        PMID: 21326529      PMCID: PMC3036461          DOI: 10.1055/s-0029-1208381

Source DB:  PubMed          Journal:  Semin Intervent Radiol        ISSN: 0739-9529            Impact factor:   1.513


  25 in total

1.  Leakages after endovascular repair of aortic aneurysms: classification based on findings at CT, angiography, and radiography.

Authors:  J Görich; N Rilinger; R Sokiranski; K H Orend; C Ermis; S C Krämer; H J Brambs; L Sunder-Plassmann; R Pamler
Journal:  Radiology       Date:  1999-12       Impact factor: 11.105

2.  Detection of endoleaks after endovascular repair of abdominal aortic aneurysm: value of unenhanced and delayed helical CT acquisitions.

Authors:  Alla M Rozenblit; Michael Patlas; Ayala T Rosenbaum; Takao Okhi; Frank J Veith; Mitchell P Laks; Zina J Ricci
Journal:  Radiology       Date:  2003-04-03       Impact factor: 11.105

3.  IMA clipping for a type ii endoleak: combined laparoscopic and endovascular approach.

Authors:  Wei Zhou; Alan B Lumsden; James Li
Journal:  Surg Laparosc Endosc Percutan Tech       Date:  2006-08       Impact factor: 1.719

4.  Treatment of type V endoleaks by endovascular redo stent-graft placement.

Authors:  Daniel Zimpfer; Maria Schoder; Roman Gottardi; Johannes Lammer; Ernst Wolner; Michael Grimm; Martin Czerny
Journal:  Ann Thorac Surg       Date:  2007-02       Impact factor: 4.330

5.  Treatment of a large type II endoleak via extraperitoneal dissection and embolization of a collateral vessel using ethylene vinyl alcohol copolymer (Onyx).

Authors:  Adrian J Ling; Rajiv Pathak; Marek Garbowski; Sanjay Nadkarni
Journal:  J Vasc Interv Radiol       Date:  2007-05       Impact factor: 3.464

6.  Intraoperative DynaCT detection and immediate correction of a type Ia endoleak following endovascular repair of abdominal aortic aneurysm.

Authors:  Lukla Biasi; Tahir Ali; Robert Hinchliffe; Rob Morgan; Ian Loftus; Matt Thompson
Journal:  Cardiovasc Intervent Radiol       Date:  2008-07-26       Impact factor: 2.740

7.  Use of CT angiography to classify endoleaks after endovascular repair of abdominal aortic aneurysms.

Authors:  S William Stavropoulos; Timothy W I Clark; Jeffrey P Carpenter; Ronald M Fairman; Harold Litt; Omaida C Velazquez; Erik Insko; Michael Farner; Richard A Baum
Journal:  J Vasc Interv Radiol       Date:  2005-05       Impact factor: 3.464

8.  Endoleakage after stent-graft treatment of abdominal aneurysm: implications on pressure and imaging--an in vitro study.

Authors:  G W Schurink; N J Aarts; J Wilde; J M van Baalen; T A Chuter; L J Schultze Kool; J H van Bockel
Journal:  J Vasc Surg       Date:  1998-08       Impact factor: 4.268

9.  Nonoperative approach to endotension.

Authors:  Ari Mennander; Georg Pimenoff; Maarit Heikkinen; Teemu Partio; Rainer Zeitlin; Juha-Pekka Salenius
Journal:  J Vasc Surg       Date:  2005-08       Impact factor: 4.268

10.  Persistent type 2 endoleak after endovascular repair of abdominal aortic aneurysm is associated with adverse late outcomes.

Authors:  John E Jones; Marvin D Atkins; David C Brewster; Thomas K Chung; Christopher J Kwolek; Glenn M LaMuraglia; Thomas M Hodgman; Richard P Cambria
Journal:  J Vasc Surg       Date:  2007-06-01       Impact factor: 4.268

View more
  10 in total

Review 1.  Hydrogel-Coated Coils: Product Description and Clinical Applications.

Authors:  Hector Ferral
Journal:  Semin Intervent Radiol       Date:  2015-12       Impact factor: 1.513

Review 2.  The role of contrast-enhanced ultrasound imaging in the follow-up of patients post-endovascular aneurysm repair.

Authors:  Nadia Jawad; Pamela Parker; Raghuram Lakshminarayan
Journal:  Ultrasound       Date:  2016-01-20

3.  Microscopic Assessment of Healing and Effectiveness of a Foam-Based Peripheral Occlusion Device.

Authors:  Staci L Jessen; Molly C Friedemann; Anne-Marie Ginn-Hedman; Lance M Graul; Steven Jokerst; Cedric B Robinson; Todd L Landsman; Fred J Clubb; Duncan J Maitland
Journal:  ACS Biomater Sci Eng       Date:  2019-09-23

4.  Endovascular Management of Type I Endoleak with Fenestrated Aortic "Cuff" and Afterwards Treatment of Endoleak Type III.

Authors:  Stevo Duvnjak
Journal:  Int J Angiol       Date:  2015-01-28

5.  Abdominal Aortic Aneurysm Type II Endoleaks.

Authors:  Mohamed S Kuziez; Luis A Sanchez; Mohamed A Zayed
Journal:  J Cardiovasc Dis Diagn       Date:  2016-08-20

6.  Natural History Of an Untreated Type 1 Endoleak: A Case Report.

Authors:  Alice Shen; Gabriel O Ologun; Hilary Keller; Lawrence Sampson
Journal:  Cureus       Date:  2017-07-24

7.  Effectiveness of Embolization of Inferior Mesenteric Artery to Prevent Type II Endoleak Following Endovascular Aneurysm Repair: A Review of the Literature.

Authors:  Makoto Samura; Noriyasu Morikage; Takahiro Mizoguchi; Yuriko Takeuchi; Takashi Nagase; Takasuke Harada; Kotaro Suehiro; Kimikazu Hamano
Journal:  Ann Vasc Dis       Date:  2018-09-25

8.  Experimental feasibility of spectral photon-counting computed tomography with two contrast agents for the detection of endoleaks following endovascular aortic repair.

Authors:  Julia Dangelmaier; Daniel Bar-Ness; Heiner Daerr; Daniela Muenzel; Salim Si-Mohamed; Sebastian Ehn; Alexander A Fingerle; Melanie A Kimm; Felix K Kopp; Loic Boussel; Ewald Roessl; Franz Pfeiffer; Ernst J Rummeny; Roland Proksa; Philippe Douek; Peter B Noël
Journal:  Eur Radiol       Date:  2018-02-19       Impact factor: 5.315

9.  Computational analysis of endovascular aortic repair proximal seal zone preservation with endoanchors: A case study in cylindrical neck anatomy.

Authors:  Erin Abbott; Sanjeev Dhara; Kameel Khabaz; Seth Sankary; Kathleen Cao; Nhung Nguyen; Trissa Babrowski; Luka Pocivavsek; Ross Milner
Journal:  JVS Vasc Sci       Date:  2021-06-24

10.  Contrast-enhanced Ultrasound in Detecting Endoleaks with Failed Computed Tomography Angiography Diagnosis after Endovascular Abdominal Aortic Aneurysm Repair.

Authors:  Xiao Yang; Yue-Xin Chen; Bo Zhang; Yu-Xin Jiang; Chang-Wei Liu; Rui-Na Zhao; Qiong Wu; Da-Ming Zhang
Journal:  Chin Med J (Engl)       Date:  2015-09-20       Impact factor: 2.628

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.