Literature DB >> 24337219

[Hybrid operation theatre in vascular surgery. Options and perspectives].

M Steinbauer1, A Katsargyris, M Greindl, I Töpel, E Verhoeven.   

Abstract

BACKGROUND: Demographic development leads to an increase in vascular interventions due to the increase in elderly and multimorbid patients. The aim of this study was to demonstrate the open interventional therapy options and their influence on staff and patients which have become possible due to the introduction of angio-hybrid operations including 3-D imaging Dyna-CT.
MATERIAL AND METHODS: The modifications with respect to radiation protection for staff, improvements for patients and the possibilities of operative 3-D imaging Dyna-CT are described based on the current literature.
RESULTS: The implementation of angio-hybrid operation theaters has resulted in new open interventional treatment options which can also be employed for high risk elderly patients with aortic and peripheral arterial pathologies. With hybrid operations the radiation exposure and contrast medium exposure can be reduced for patients and an improvement in the results can also be achieved. The implementation of 3-D imaging in the angio-hybrid operation theater could also lead to further improvements, especially for complex aortic procedures. DISCUSSION: Using angio-hybrid operational procedures complex interventions can be carried out with more safety for patients and personnel. The implementation of 3-D imaging Dyna-CT offers additional interesting options for complex aortic procedures.

Entities:  

Mesh:

Year:  2013        PMID: 24337219     DOI: 10.1007/s00104-013-2557-1

Source DB:  PubMed          Journal:  Chirurg        ISSN: 0009-4722            Impact factor:   0.955


  8 in total

1.  Inter-Society Consensus for the Management of Peripheral Arterial Disease (TASC II).

Authors:  L Norgren; W R Hiatt; J A Dormandy; M R Nehler; K A Harris; F G R Fowkes
Journal:  J Vasc Surg       Date:  2007-01       Impact factor: 4.268

2.  Intraoperative DynaCT detection and immediate correction of a type Ia endoleak following endovascular repair of abdominal aortic aneurysm.

Authors:  Lukla Biasi; Tahir Ali; Robert Hinchliffe; Rob Morgan; Ian Loftus; Matt Thompson
Journal:  Cardiovasc Intervent Radiol       Date:  2008-07-26       Impact factor: 2.740

Review 3.  [Hybrid operating rooms: only for advanced endovascular procedures?].

Authors:  E Verhoeven; A Katsargyris; I Töpel; M Steinbauer
Journal:  Zentralbl Chir       Date:  2013-08-01       Impact factor: 0.942

4.  Update on endovascular repair for ruptured abdominal aortic aneurysms.

Authors:  M R Kapma; A C Vahl; F Bekkema; E L G Verhoeven
Journal:  Acta Chir Belg       Date:  2009 Nov-Dec       Impact factor: 1.090

Review 5.  [The economic solution for integrating radiology and surgery: hybrid OR].

Authors:  T Freitag; S Langer
Journal:  Zentralbl Chir       Date:  2012-11-07       Impact factor: 0.942

Review 6.  [The hybrid operating room. Home of high-end intraoperative imaging].

Authors:  F Gebhard; C Riepl; P Richter; A Liebold; H Gorki; R Wirtz; R König; F Wilde; A Schramm; M Kraus
Journal:  Unfallchirurg       Date:  2012-02       Impact factor: 1.000

Review 7.  Image optimization during endovascular aneurysm repair.

Authors:  T Gregory Walker; Sanjeeva P Kalva; Suvranu Ganguli; Rahmi Öklü; Gloria M Salazar; Arthur C Waltman; Stephan Wicky
Journal:  AJR Am J Roentgenol       Date:  2012-01       Impact factor: 3.959

8.  Initial observations of endovascular aneurysm repair using Dyna-CT.

Authors:  Kari Ravn Eide; Asbjørn Ødegård; Hans Olav Myhre; Olav Haraldseth
Journal:  J Endovasc Ther       Date:  2007-02       Impact factor: 3.487

  8 in total
  3 in total

1.  [Hybrid operating rooms versus conventional operating rooms : Economic comparisons in vascular surgery using the example of endovascular aneurysm repair].

Authors:  N Attigah; S Demirel; M Hakimi; H Bruijnen; O Schöffski; A Müller; U Geis; D Böckler
Journal:  Chirurg       Date:  2017-07       Impact factor: 0.955

2.  Image-guided procedures in the hybrid operating room: A systematic scoping review.

Authors:  Ilse M Spenkelink; Jan Heidkamp; Jurgen J Fütterer; Maroeska M Rovers
Journal:  PLoS One       Date:  2022-04-01       Impact factor: 3.240

3.  Radiation exposure for intraoperative 3D scans in a hybrid operating room: how to reduce radiation exposure for the surgical team.

Authors:  K Schuetze; M Kraus; A Eickhoff; F Gebhard; P H Richter
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-03-29       Impact factor: 2.924

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.