Literature DB >> 35502374

Intraoperative cone beam computed tomography of tracheal stenting for stenosis and fistula diseases: a retrospective cohort study.

Jing Li1, Kaihao Xu1, Zhaonan Li1, Yahua Li1, Xueliang Zhou1, Juanfang Liu1, Yuan Yao1, Zaoqu Liu1, De-Chao Jiao1, Xinwei Han1.   

Abstract

Background: Angiographic computed tomography (CT) is useful in various medical contexts, but little research has been presented regarding the application of cone beam CT (CBCT) in airway stenting. This study set out to evaluate the clinical feasibility of using CBCT in airway stent placement in a single-center retrospective cohort.
Methods: A total of 228 patients with stenosis or fistula diseases were treated with metallic airway stents in the First Affiliated Hospital of Zhengzhou University from January 1, 2015, to December 31, 2018. Of them, 128 patients underwent fluoroscopy-guided airway stenting. CBCT scanning was performed on the other 100 patients during and after treatment, and their images were compared with those from postoperative multidetector CT (MDCT). The outcomes and complications in the CBCT-guided and fluoroscopy-guided groups were also assessed via Pearson's χ2 test or Fisher's exact test.
Results: Tracheal stenting was performed successfully on the first attempt for 90 patients in the CBCT-guided group and 123 patients in the fluoroscopy-guided group. The mean measured diameters of the central airway in the CBCT images and MDCT images were 18.2±2.81 and 19.0±2.33 mm, respectively, and the mean lengths were 58.7±16.82 and 58.5±17.06 mm, respectively. In the CBCT-guided group and the fluoroscopy-guided group, the mean scores for visibility of the distal bronchus were 3.7±0.49 and 3.9±0.34, respectively; the mean scores for the pulmonary parenchyma were 3.3±0.71 and 3.9±0.31, respectively; and the mean scores for the airway above the upper stent graft were 1.8±0.41 and 4.0±0.20, respectively. Two of the three anatomical areas were reproduced in a diagnostically relevant way. The major complications rate was 7% and 19% in the CBCT-guided and fluoroscopy-guided groups, respectively. Conclusions: CBCT produces images with sufficient quality to replace MDCT as a reasonable control measure after stent implantation, and its use during surgery reduces complications relating to airway stent placement. 2022 Quantitative Imaging in Medicine and Surgery. All rights reserved.

Entities:  

Keywords:  Cone beam computed tomography (CBCT) tracheal stent; airway obstruction; fistula

Year:  2022        PMID: 35502374      PMCID: PMC9014159          DOI: 10.21037/qims-21-858

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  27 in total

1.  Tracheal compression by the stomach following gastric pull-up: diagnosis with CT and treatment with expandable metallic stent placement.

Authors:  Suil Kim; Michael B Gotway; W Richard Webb; Roy L Gordon; Jeffrey A Golden
Journal:  Chest       Date:  2002-03       Impact factor: 9.410

2.  Outcomes of tracheobronchial stent placement for benign disease.

Authors:  Raymond H Thornton; Roy L Gordon; Robert K Kerlan; Jeanne M LaBerge; Mark W Wilson; Kristen A Wolanske; Michael B Gotway; Geoffrey S Hastings; Jeffrey A Golden
Journal:  Radiology       Date:  2006-07       Impact factor: 11.105

3.  Digital subtraction angiography laboratory with inbuilt CT (DynaCT): application during intracranial anurysm embolization.

Authors:  V Gupta; M Chugh; B S Walia; S Vaishya; A N Jha
Journal:  Neurol India       Date:  2008 Jan-Mar       Impact factor: 2.117

4.  DynaCT during EVAR--a comparison with multidetector CT.

Authors:  K R Eide; A Ødegård; H O Myhre; S Lydersen; S Hatlinghus; O Haraldseth
Journal:  Eur J Vasc Endovasc Surg       Date:  2008-11-17       Impact factor: 7.069

5.  Application of High-Resolution C-Arm CT Combined with Streak Metal Artifact Removal Technology for the Stent-Assisted Embolization of Intracranial Aneurysms.

Authors:  T-F Li; J Ma; X-W Han; P-J Fu; R-N Niu; W-Z Luo; J-Z Ren
Journal:  AJNR Am J Neuroradiol       Date:  2019-09-26       Impact factor: 3.825

6.  Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules.

Authors:  Nicola Rotolo; Chiara Floridi; Andrea Imperatori; Federico Fontana; Anna Maria Ierardi; Monica Mangini; Veronica Arlant; Giuseppe De Marchi; Raffaele Novario; Lorenzo Dominioni; Carlo Fugazzola; Gianpaolo Carrafiello
Journal:  Eur Radiol       Date:  2015-06-06       Impact factor: 5.315

Review 7.  Multidetector CT evaluation of airway stents: what the radiologist should know.

Authors:  Myrna C B Godoy; David A Saldana; Praveen P Rao; Ioannis Vlahos; David P Naidich; Marcelo F Benveniste; Jeremy J Erasmus; Edith M Marom; David Ost
Journal:  Radiographics       Date:  2014 Nov-Dec       Impact factor: 5.333

8.  Fully covered self-expandable metal stent in tracheobronchial disorders: clinical experience.

Authors:  Roberto Marchese; Grazia Poidomani; Giuseppe Paglino; Claudia Crimi; Chiara Lo Nigro; Vincenzo Argano
Journal:  Respiration       Date:  2015-01-15       Impact factor: 3.580

9.  Clinical outcomes of self-expandable metallic stents for malignant obstructive atelectasis.

Authors:  Yonghua Bi; Xiaoyan Zhu; Zepeng Yu; Mengfei Yi; Xinwei Han; Jianzhuang Ren
Journal:  Sci Rep       Date:  2020-02-27       Impact factor: 4.379

View more