Literature DB >> 18648807

Is 16-frame really superior to 8-frame gated SPECT for the assessment of left ventricular volumes and ejection fraction? Comparison of two simultaneously acquired gated SPECT studies.

Giulia Montelatici1, Roberto Sciagrà, Alessandro Passeri, Manjola Dona, Alberto Pupi.   

Abstract

PURPOSE: Conflicting data exist about the difference between 8- and 16-frame gated single-photon emission computed tomography (SPECT) left ventricular volumes and ejection fraction (EF); moreover, the influence of framing on detection of stress-induced functional changes is unknown.
METHODS: In 133 patients, two separate gated SPECT studies, one with 8 and one with 16 frames, were simultaneously acquired during a single gantry orbit using dedicated software. In 33 of 133 patients, two additional studies (with 8 and 16 frames, respectively) were acquired using arrhythmia rejection. Left ventricular EF and volumes were calculated using the QGS software. Stress-induced ischemia was identified on summed perfusion images.
RESULTS: Arrhythmia-rejection did not influence volumes and EF independently of framing rate. Using data without arrhythmia-rejection, there was a significant difference in volumes and EF between 8 and 16 frames both in resting and post-stress gated SPECT. However, the difference was small: 2.6% for resting and 2.8% for post-stress EF. Both using 8 and 16 frames, there were significantly larger volumes and lower EF in patients with than without stress-induced ischemia. A stress-induced decrease >5 EF units was observed in 26 of 133 patients using 8 and in 23 of 133 using 16 frames, respectively, with finding agreement in 19 patients.
CONCLUSIONS: Comparing two simultaneously acquired studies, the use of 16 instead of 8 frames has minor and predictable influence on functional data. Furthermore, there are no differences in the detection of stress-induced functional changes. The advantage of 16 over 8 frames in the daily clinical practice appears questionable.

Entities:  

Mesh:

Year:  2008        PMID: 18648807     DOI: 10.1007/s00259-008-0866-2

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  20 in total

1.  A realistic 3-D gated cardiac phantom for quality control of gated myocardial perfusion SPET: the Amsterdam gated (AGATE) cardiac phantom.

Authors:  Jacco J N Visser; Ellinor Busemann Sokole; Hein J Verberne; Jan B A Habraken; Huybert J F van de Stadt; Joris E N Jaspers; Morgan Shehata; Paul M Heeman; Berthe L F van Eck-Smit
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-02       Impact factor: 9.236

2.  Postischemic stunning can affect left ventricular ejection fraction and regional wall motion on post-stress gated sestamibi tomograms.

Authors:  L L Johnson; S A Verdesca; W Y Aude; R C Xavier; L T Nott; M W Campanella; G Germano
Journal:  J Am Coll Cardiol       Date:  1997-12       Impact factor: 24.094

3.  Regional myocardial wall thickening and global ejection fraction in patients with low angiographic left ventricular ejection fraction assessed by visual and quantitative resting ECG-gated 99mTc-tetrofosmin single-photon emission tomography and magnetic resonance imaging.

Authors:  J C Stollfuss; F Haas; I Matsunari; J Neverve; S Nekolla; J Schneider-Eicke; U Schricke; S Ziegler; M Schwaiger
Journal:  Eur J Nucl Med       Date:  1998-05

4.  Assessment of diastolic function using 16-frame 99mTc-sestamibi gated myocardial perfusion SPECT: normal values.

Authors:  Cigdem Akincioglu; Daniel S Berman; Hidetaka Nishina; Paul B Kavanagh; Piotr J Slomka; Aiden Abidov; Sean Hayes; John D Friedman; Guido Germano
Journal:  J Nucl Med       Date:  2005-07       Impact factor: 10.057

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Quantification of left ventricular volumes and ejection fraction from 16- and rebinned 8-frame gated 99mTc-tetrofosmin SPECT. Comparison of 4D-MSPECT and QGS.

Authors:  W M Schaefer; H-J Kaiser; H Kuehl; K-C Koch; B Nowak; U Buell
Journal:  Nuklearmedizin       Date:  2007       Impact factor: 1.379

7.  Left ventricular ejection fraction assessed from gated technetium-99m-sestamibi SPECT.

Authors:  E G DePuey; K Nichols; C Dobrinsky
Journal:  J Nucl Med       Date:  1993-11       Impact factor: 10.057

8.  201Tl and 99mTc-MIBI gated SPECT in patients with large perfusion defects and left ventricular dysfunction: comparison with equilibrium radionuclide angiography.

Authors:  A Manrique; M Faraggi; P Véra; D Vilain; R Lebtahi; A Cribier; D Le Guludec
Journal:  J Nucl Med       Date:  1999-05       Impact factor: 10.057

9.  Relationship of gated SPECT ventricular function parameters to angiographic measurements.

Authors:  K Nichols; J Tamis; E G DePuey; J Mieres; S Malhotra; A Rozanski
Journal:  J Nucl Cardiol       Date:  1998 May-Jun       Impact factor: 5.952

10.  American Society of Nuclear Cardiology position statement on electrocardiographic gating of myocardial perfusion SPECT scintigrams.

Authors:  T M Bateman; D S Berman; G V Heller; K A Brown; M D Cerqueira; M S Verani; J E Udelson
Journal:  J Nucl Cardiol       Date:  1999 Jul-Aug       Impact factor: 3.872

View more
  7 in total

1.  Prognostic implications of post-stress ejection fraction decrease detected by gated SPECT in the absence of stress-induced perfusion abnormalities.

Authors:  Manjola Dona; Lucia Massi; Leonardo Settimo; Matteo Bartolini; Gianluca Giannì; Alberto Pupi; Roberto Sciagrà
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-03       Impact factor: 9.236

2.  A comparison of 8 and 16 frames gated SPECT imaging for determination of left ventricular volumes and ejection fraction: effects of gender and myocardial counts.

Authors:  Mahdi Mazinani; Mohammad Ali Tajik-Mansoury; Mahsa Sabour; Majid Jadidi
Journal:  Int J Cardiovasc Imaging       Date:  2021-02-11       Impact factor: 2.357

3.  Comparison of 8-frame and 16-frame thallium-201 gated myocardial perfusion SPECT for determining left ventricular systolic and diastolic parameters.

Authors:  Satoshi Kurisu; Yoji Sumimoto; Hiroki Ikenaga; Noriaki Watanabe; Ken Ishibashi; Yoshihiro Dohi; Yukihiro Fukuda; Yasuki Kihara
Journal:  Heart Vessels       Date:  2016-12-17       Impact factor: 2.037

4.  Reliability of myocardial perfusion gated SPECT for the reproducible evaluation of resting left ventricular functional parameters in long-term follow-up.

Authors:  Roberto Sciagrà; Valentina Berti; Sabrina Genovese; Alberto Pupi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-08       Impact factor: 9.236

5.  Factors That Impact Evaluation of Left Ventricular Systolic Parameters in Myocardial Perfusion Gated SPECT with 16 Frame and 8 Frame Acquisition Models.

Authors:  Mojtaba Ansari; Hoda Hashemi; Mehdi Soltanshahi; Mohsen Qutbi; Zahra Azizmohammadi; Faraj Tabeie; Hamid Javadi; Esmail Jafari; Maryam Barekat; Majid Assadi
Journal:  Mol Imaging Radionucl Ther       Date:  2018-06-07

6.  Technical note: Partitioning of gated single photon emission computed tomography raw data for protocols optimization.

Authors:  Cleiton Cavalcante Queiroz; Marcos Antonio Dorea Machado; Antonio Augusto Brito Ximenes; Andre Gustavo Silva Pino; Eduardo Martins Netto
Journal:  J Appl Clin Med Phys       Date:  2021-12-17       Impact factor: 2.102

7.  The impact of frame numbers on cardiac ECG-gated SPECT images with interpolated extra frames using echocardiography.

Authors:  Maghsoud Sarebani; Mohammad Bagher Shiran; Ahmad Bitarafan-Rajabi; Feridoon Rastgou; Zahra Ojaghi Haghighi; Ali Abbasian Ardakani
Journal:  Med J Islam Repub Iran       Date:  2020-06-03
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.