Literature DB >> 18621546

A Script-Assisted Microscopy (SAM) package to improve data acquisition rates on FEI Tecnai electron microscopes equipped with Gatan CCD cameras.

Jian Shi1, Dewight R Williams, Phoebe L Stewart.   

Abstract

High throughput methods of data acquisition are advantageous for cryoelectron microscopy and single particle reconstruction as high-resolution structure determination requires thousands of particle images. We have developed a semi-automated data collection method that utilizes the scripting languages provided by FEI for their Tecnai User Interface (TUI) and by Gatan for their Digital Micrograph package. Our Script-Assisted Microscopy (SAM) method allows for the selection of multiple locations within a low magnification, search mode, micrograph and for subsequent automated imaging of these locations at a higher exposure magnification. The SAM approach permits the user to retain control over the microscope, while streamlining the most repetitive steps of collecting and evaluating micrographs. With SAM, we have found an average of 1000 micrographs can be collected per day on any grid type, either irregular homemade grids or prefabricated grids with regularly spaced holes. This rate of data collection represents a fivefold improvement over our manual collection rates. SAM provides an example of an individually tailored approach to data acquisition utilizing the scripting interfaces provided by the equipment manufacturers. The SAM method has proven valuable for determination of a subnanometer resolution cryoEM structure of DNA-dependent protein kinase catalytic subunit (DNA-PKcs), a 469kDa protein.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18621546      PMCID: PMC2572106          DOI: 10.1016/j.jsb.2008.05.011

Source DB:  PubMed          Journal:  J Struct Biol        ISSN: 1047-8477            Impact factor:   2.867


  14 in total

1.  EMAN: semiautomated software for high-resolution single-particle reconstructions.

Authors:  S J Ludtke; P R Baldwin; W Chiu
Journal:  J Struct Biol       Date:  1999-12-01       Impact factor: 2.867

2.  Improving the positional accuracy of the goniometer on the Philips CM series TEM.

Authors:  J Pulokas; C Green; N Kisseberth; C S Potter; B Carragher
Journal:  J Struct Biol       Date:  1999-12-30       Impact factor: 2.867

3.  Automated data collection with a Tecnai 12 electron microscope: applications for molecular imaging by cryomicroscopy.

Authors:  P Zhang; A Beatty; J L Milne; S Subramaniam
Journal:  J Struct Biol       Date:  2001-09       Impact factor: 2.867

4.  Automated electron microscope tomography using robust prediction of specimen movements.

Authors:  David N Mastronarde
Journal:  J Struct Biol       Date:  2005-10       Impact factor: 2.867

5.  Automated molecular microscopy: the new Leginon system.

Authors:  Christian Suloway; James Pulokas; Denis Fellmann; Anchi Cheng; Francisco Guerra; Joel Quispe; Scott Stagg; Clinton S Potter; Bridget Carragher
Journal:  J Struct Biol       Date:  2005-07       Impact factor: 2.867

6.  Automated cryoEM data acquisition and analysis of 284742 particles of GroEL.

Authors:  Scott M Stagg; Gabriel C Lander; James Pulokas; Denis Fellmann; Anchi Cheng; Joel D Quispe; Satya P Mallick; Radomir M Avila; Bridget Carragher; Clinton S Potter
Journal:  J Struct Biol       Date:  2006-05-22       Impact factor: 2.867

7.  Does contamination buildup limit throughput for automated cryoEM?

Authors:  Anchi Cheng; Denis Fellmann; James Pulokas; Clinton S Potter; Bridget Carragher
Journal:  J Struct Biol       Date:  2006-04-05       Impact factor: 2.867

8.  Automated acquisition of cryo-electron micrographs for single particle reconstruction on an FEI Tecnai electron microscope.

Authors:  Jianlin Lei; Joachim Frank
Journal:  J Struct Biol       Date:  2005-04       Impact factor: 2.867

9.  Automated image acquisition and processing using a new generation of 4K x 4K CCD cameras for cryo electron microscopic studies of macromolecular assemblies.

Authors:  Peijun Zhang; Mario J Borgnia; Paul Mooney; Dan Shi; Ming Pan; Philip O'Herron; Albert Mao; David Brogan; Jacqueline L S Milne; Sriram Subramaniam
Journal:  J Struct Biol       Date:  2003-08       Impact factor: 2.867

10.  A 9 angstroms single particle reconstruction from CCD captured images on a 200 kV electron cryomicroscope.

Authors:  Christopher R Booth; Wen Jiang; Matthew L Baker; Z Hong Zhou; Steven J Ludtke; Wah Chiu
Journal:  J Struct Biol       Date:  2004-08       Impact factor: 2.867

View more
  9 in total

Review 1.  Automated data collection in single particle electron microscopy.

Authors:  Yong Zi Tan; Anchi Cheng; Clinton S Potter; Bridget Carragher
Journal:  Microscopy (Oxf)       Date:  2015-12-15       Impact factor: 1.571

2.  Cryo-electron microscopy structure of adenovirus type 2 temperature-sensitive mutant 1 reveals insight into the cell entry defect.

Authors:  Mariena Silvestry; Steffen Lindert; Jason G Smith; Oana Maier; Christopher M Wiethoff; Glen R Nemerow; Phoebe L Stewart
Journal:  J Virol       Date:  2009-05-20       Impact factor: 5.103

3.  Single particle analysis integrated with microscopy: a high-throughput approach for reconstructing icosahedral particles.

Authors:  Xiaodong Yan; Giovanni Cardone; Xing Zhang; Z Hong Zhou; Timothy S Baker
Journal:  J Struct Biol       Date:  2014-03-05       Impact factor: 2.867

4.  An approach to automated acquisition of cryoEM images from lacey carbon grids.

Authors:  William V Nicholson; Howard White; John Trinick
Journal:  J Struct Biol       Date:  2010-09-08       Impact factor: 2.867

5.  Engineering of a Polydisperse Small Heat-Shock Protein Reveals Conserved Motifs of Oligomer Plasticity.

Authors:  Sanjay Mishra; Shane A Chandler; Dewight Williams; Derek P Claxton; Hanane A Koteiche; Phoebe L Stewart; Justin L P Benesch; Hassane S Mchaourab
Journal:  Structure       Date:  2018-07-05       Impact factor: 5.006

6.  Insight into the mechanisms of adenovirus capsid disassembly from studies of defensin neutralization.

Authors:  Jason G Smith; Mariena Silvestry; Steffen Lindert; Wuyuan Lu; Glen R Nemerow; Phoebe L Stewart
Journal:  PLoS Pathog       Date:  2010-06-24       Impact factor: 6.823

7.  Three-dimensional reconstruction of icosahedral particles from single micrographs in real time at the microscope.

Authors:  Giovanni Cardone; Xiaodong Yan; Robert S Sinkovits; Jinghua Tang; Timothy S Baker
Journal:  J Struct Biol       Date:  2013-07-25       Impact factor: 2.867

8.  Cryo-electron microscopy structure of an adenovirus-integrin complex indicates conformational changes in both penton base and integrin.

Authors:  Steffen Lindert; Mariena Silvestry; Tina-Marie Mullen; Glen R Nemerow; Phoebe L Stewart
Journal:  J Virol       Date:  2009-09-02       Impact factor: 5.103

9.  Fully automated, sequential tilt-series acquisition with Leginon.

Authors:  Christian Suloway; Jian Shi; Anchi Cheng; James Pulokas; Bridget Carragher; Clinton S Potter; Shawn Q Zheng; David A Agard; Grant J Jensen
Journal:  J Struct Biol       Date:  2009-04-08       Impact factor: 2.867

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.