Three-dimensional reconstruction of icosahedral particles from single micrographs in real time at the microscope.

Giovanni Cardone1, Xiaodong Yan1, Robert S Sinkovits2, Jinghua Tang1, Timothy S Baker3.   

Abstract

Single particle analysis is a valuable tool in cryo-electron microscopy for determining the structure of biological complexes. However, the conformational state and the preparation of the sample are factors that play a critical role in the ultimate attainable resolution. In some cases extensive analysis at the microscope of a sample under different conditions is required to derive the optimal acquisition conditions. Currently this analysis is limited to raw micrographs, thus conveying only limited information on the structure of the complex. We are developing a computing system that generates a three-dimensional reconstruction from a single micrograph acquired under cryogenic and low dose conditions, and containing particles with icosahedral symmetry. The system provides the microscopist with immediate structural information from a sample while it is in the microscope and during the preliminary acquisition stage. The system is designed to run without user intervention on a multi-processor computing resource and integrates all the processing steps required for the analysis. Tests performed on experimental data sets show that the probability of obtaining a reliable reconstruction from one micrograph is primarily determined by the quality of the sample, with success rates close to 100% when sample conditions are optimal, and decreasing to about 60% when conditions are sub-optimal. The time required to generate a reconstruction depends significantly on the diameter of the particles, and in most instances takes about 1min. The proposed approach can provide valuable three-dimensional information, albeit at low resolution, on conformational states, epitope binding, and stoichiometry of icosahedral multi-protein complexes.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  3D reconstruction; Automation; Cryo-electron microscopy; Icosahedral particles; Image processing; Single particle analysis

Mesh:

Year:  2013        PMID: 23891839      PMCID: PMC3831522          DOI: 10.1016/j.jsb.2013.07.007

Source DB:  PubMed          Journal:  J Struct Biol        ISSN: 1047-8477            Impact factor:   2.867


  24 in total

1.  Accurate determination of local defocus and specimen tilt in electron microscopy.

Authors:  Joseph A Mindell; Nikolaus Grigorieff
Journal:  J Struct Biol       Date:  2003-06       Impact factor: 2.867

2.  Cryo-EM, Part B: 3-D reconstruction. Preface.

Authors:  Grant J Jensen
Journal:  Methods Enzymol       Date:  2010       Impact factor: 1.600

3.  ACE: automated CTF estimation.

Authors:  Satya P Mallick; Bridget Carragher; Clinton S Potter; David J Kriegman
Journal:  Ultramicroscopy       Date:  2005-03-23       Impact factor: 2.689

4.  Bsoft: image processing and molecular modeling for electron microscopy.

Authors:  J Bernard Heymann; David M Belnap
Journal:  J Struct Biol       Date:  2006-06-28       Impact factor: 2.867

5.  AUTO3DEM--an automated and high throughput program for image reconstruction of icosahedral particles.

Authors:  Xiaodong Yan; Robert S Sinkovits; Timothy S Baker
Journal:  J Struct Biol       Date:  2006-08-25       Impact factor: 2.867

6.  A model-based approach for determining orientations of biological macromolecules imaged by cryoelectron microscopy.

Authors:  T S Baker; R H Cheng
Journal:  J Struct Biol       Date:  1996 Jan-Feb       Impact factor: 2.867

7.  Identification of spherical virus particles in digitized images of entire electron micrographs.

Authors:  I M Boier Martin; D C Marinescu; R E Lynch; T S Baker
Journal:  J Struct Biol       Date:  1997-11       Impact factor: 2.867

8.  Structure of Fusarium poae virus 1 shows conserved and variable elements of partitivirus capsids and evolutionary relationships to picobirnavirus.

Authors:  Jinghua Tang; Wendy F Ochoa; Hua Li; Wendy M Havens; Max L Nibert; Said A Ghabrial; Timothy S Baker
Journal:  J Struct Biol       Date:  2010-07-03       Impact factor: 2.867

9.  A Script-Assisted Microscopy (SAM) package to improve data acquisition rates on FEI Tecnai electron microscopes equipped with Gatan CCD cameras.

Authors:  Jian Shi; Dewight R Williams; Phoebe L Stewart
Journal:  J Struct Biol       Date:  2008-06-04       Impact factor: 2.867

10.  DoG Picker and TiltPicker: software tools to facilitate particle selection in single particle electron microscopy.

Authors:  N R Voss; C K Yoshioka; M Radermacher; C S Potter; B Carragher
Journal:  J Struct Biol       Date:  2009-05       Impact factor: 2.867

View more
  2 in total

1.  Single particle analysis integrated with microscopy: a high-throughput approach for reconstructing icosahedral particles.

Authors:  Xiaodong Yan; Giovanni Cardone; Xing Zhang; Z Hong Zhou; Timothy S Baker
Journal:  J Struct Biol       Date:  2014-03-05       Impact factor: 2.867

2.  Validation of 3D EM Reconstructions: The Phantom in the Noise.

Authors:  J Bernard Heymann
Journal:  AIMS Biophys       Date:  2015
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.