Literature DB >> 18614810

Screening tests for detecting open-angle glaucoma: systematic review and meta-analysis.

Graham Mowatt1, Jennifer M Burr, Jonathan A Cook, M A Rehman Siddiqui, Craig Ramsay, Cynthia Fraser, Augusto Azuara-Blanco, Jonathan J Deeks.   

Abstract

PURPOSE: To assess the comparative accuracy of potential screening tests for open angle glaucoma (OAG).
METHODS: Medline, Embase, Biosis (to November 2005), Science Citation Index (to December 2005), and The Cochrane Library (Issue 4, 2005) were searched. Studies assessing candidate screening tests for detecting OAG in persons older than 40 years that reported true and false positives and negatives were included. Meta-analysis was undertaken using the hierarchical summary receiver operating characteristic model.
RESULTS: Forty studies enrolling over 48,000 people reported nine tests. Most tests were reported by only a few studies. Frequency-doubling technology (FDT; C-20-1) was significantly more sensitive than ophthalmoscopy (30, 95% credible interval [CrI] 0-62) and Goldmann applanation tonometry (GAT; 45, 95% CrI 17-68), whereas threshold standard automated perimetry (SAP) and Heidelberg Retinal Tomograph (HRT II) were both more sensitive than GAT (41, 95% CrI 14-64 and 39, 95% CrI 3-64, respectively). GAT was more specific than both FDT C-20-5 (19, 95% CrI 0-53) and threshold SAP (14, 95% CrI 1-37). Judging performance by diagnostic odds ratio, FDT, oculokinetic perimetry, and HRT II are promising tests. Ophthalmoscopy, SAP, retinal photography, and GAT had relatively poor performance as single tests. These findings are based on heterogeneous data of limited quality and as such are associated with considerable uncertainty.
CONCLUSIONS: No test or group of tests was clearly superior for glaucoma screening. Further research is needed to evaluate the comparative accuracy of the most promising tests.

Entities:  

Mesh:

Year:  2008        PMID: 18614810     DOI: 10.1167/iovs.07-1501

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  30 in total

1.  Relationships between visual field sensitivity and spectral absorption properties of the neuroretinal rim in glaucoma by multispectral imaging.

Authors:  Jonathan Denniss; Ingo Schiessl; Vincent Nourrit; Cecilia H Fenerty; Ramesh Gautam; David B Henson
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-11-07       Impact factor: 4.799

2.  Accuracy of the RTVue-100 Fourier-domain optical coherence tomograph in an optic neuropathy screening trial.

Authors:  Anita Garas; Péter Kóthy; Gábor Holló
Journal:  Int Ophthalmol       Date:  2011-03-20       Impact factor: 2.031

3.  Population and high-risk group screening for glaucoma: the Los Angeles Latino Eye Study.

Authors:  Brian A Francis; Rohit Varma; Cheryl Vigen; Mei-Ying Lai; Jonathan Winarko; Betsy Nguyen; Stanley Azen
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-08-05       Impact factor: 4.799

4.  Short-duration transient visual evoked potentials and color reflectivity discretization analysis in glaucoma patients and suspects.

Authors:  Michael Waisbourd; Rebekah H Gensure; Ardalan Aminlari; Sonya B Shah; Nitasha Khanna; Neil Sood; Jeanne Molineaux; Alberto Gonzalez; Jonathan S Myers; L Jay Katz
Journal:  Int J Ophthalmol       Date:  2017-02-18       Impact factor: 1.779

5.  Glaucoma detection with damato multifixation campimetry online.

Authors:  A S Olsen; M Alberti; L Serup; M la Cour; B Damato; M Kolko
Journal:  Eye (Lond)       Date:  2016-03-18       Impact factor: 3.775

6.  Gaps in Glaucoma care: A systematic review of monoscopic disc photos to screen for glaucoma.

Authors:  Paula Anne Newman-Casey; Angela J Verkade; Gale Oren; Alan L Robin
Journal:  Expert Rev Ophthalmol       Date:  2014-12

Review 7.  [Smartphone-based fundus imaging: applications and adapters].

Authors:  Linus G Jansen; Thomas Schultz; Frank G Holz; Robert P Finger; Maximilian W M Wintergerst
Journal:  Ophthalmologe       Date:  2021-12-16       Impact factor: 1.059

Review 8.  Optic nerve head and fibre layer imaging for diagnosing glaucoma.

Authors:  Manuele Michelessi; Ersilia Lucenteforte; Francesco Oddone; Miriam Brazzelli; Mariacristina Parravano; Sara Franchi; Sueko M Ng; Gianni Virgili
Journal:  Cochrane Database Syst Rev       Date:  2015-11-30

9.  [Health-economic aspects of glaucoma screening].

Authors:  C Hirneiss; A Niedermaier; M Kernt; A Kampik; A S Neubauer
Journal:  Ophthalmologe       Date:  2010-02       Impact factor: 1.059

10.  Developing the specifications of an open angle glaucoma screening intervention in the United Kingdom: a Delphi approach.

Authors:  Susan E Campbell; Augusto Azuara-Blanco; Marion K Campbell; Jillian J Francis; Alexandra C Greene; Craig R Ramsay; Jennifer M Burr
Journal:  BMC Health Serv Res       Date:  2012-12-05       Impact factor: 2.655

View more