Literature DB >> 21424554

Accuracy of the RTVue-100 Fourier-domain optical coherence tomograph in an optic neuropathy screening trial.

Anita Garas1, Péter Kóthy, Gábor Holló.   

Abstract

The aim of this study was to evaluate the usefulness of the RTVue-100 Fourier-domain optical coherence tomograph (RTVue-100 OCT) in screening for glaucoma and non-arteritic anterior ischemic optic neuropathy (NA-AION). In a non-population-based pre-publicised trial, self-recruited Caucasian participants were screened for glaucoma and NA-AION using the RTVue-100 OCT, and also by independent clinical examination. For the RTVue-100 OCT measurements, the optic nerve head (ONH) scan and the macular ganglion cell complex (GCC) scan were applied. Subjects with possible optic neuropathy (as indicated by any of the scans and/or by the clinical examination) underwent a detailed clinical investigation to verify or exclude the disease. Of the 146 attendees, 133 participants (256 eyes) successfully underwent the RTVue-100 OCT measurements. Of these, six eyes (2.3%) had glaucoma and three eyes (1.2%) had partial optic atrophy due to earlier NA-AION. The retinal nerve fibre layer (RNFL) parameters (provided by the instrument software) had 99.2-99.6% specificity, 96.5-96.9% accuracy, and positive likelihood ratio (PLR) of 27.3-54.7, but only 11.1-22.2% sensitivity. Accuracy and PLR for the ONH parameters were <95% and <8.3, respectively. The GCC scan of the macula provided up to 95.9% specificity, 94.0% accuracy, 10.7 PLR and 44.4% sensitivity. During the screening of this Caucasian population with 3.5% prevalence of optic neuropathy due to glaucoma and NA-AION, the RTVue-100 OCT was found to be useful for screening, with both RNFL and GCC parameters providing high accuracy and PLR values >10.

Entities:  

Mesh:

Year:  2011        PMID: 21424554     DOI: 10.1007/s10792-011-9433-0

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  23 in total

Review 1.  Uses and abuses of screening tests.

Authors:  David A Grimes; Kenneth F Schulz
Journal:  Lancet       Date:  2002-03-09       Impact factor: 79.321

2.  Accuracy of scanning laser polarimetry, scanning laser tomography, and their combination in a glaucoma screening trial.

Authors:  Márta Tóth; Péter Kóthy; Gábor Holló
Journal:  J Glaucoma       Date:  2008-12       Impact factor: 2.503

3.  Incidence of nonarteritic anterior ischemic optic neuropathy.

Authors:  M G Hattenhauer; J A Leavitt; D O Hodge; R Grill; D T Gray
Journal:  Am J Ophthalmol       Date:  1997-01       Impact factor: 5.258

4.  Racial variations in the prevalence of primary open-angle glaucoma. The Baltimore Eye Survey.

Authors:  J M Tielsch; A Sommer; J Katz; R M Royall; H A Quigley; J Javitt
Journal:  JAMA       Date:  1991-07-17       Impact factor: 56.272

5.  Prevalence of glaucoma in the wroclaw population. The wroclaw epidemiological study.

Authors:  Maria H Nizankowska; Radoslaw Kaczmarek
Journal:  Ophthalmic Epidemiol       Date:  2005-12       Impact factor: 1.648

6.  Prevalence of primary open-angle glaucoma in a Spanish population: the Segovia study.

Authors:  Alfonso Antón; Maria T Andrada; Vicente Mujica; Miguel A Calle; Javier Portela; Agustin Mayo
Journal:  J Glaucoma       Date:  2004-10       Impact factor: 2.503

7.  Thickness profiles of retinal layers by optical coherence tomography image segmentation.

Authors:  Ahmet Murat Bagci; Mahnaz Shahidi; Rashid Ansari; Michael Blair; Norman Paul Blair; Ruth Zelkha
Journal:  Am J Ophthalmol       Date:  2008-08-15       Impact factor: 5.258

8.  The number of people with glaucoma worldwide in 2010 and 2020.

Authors:  H A Quigley; A T Broman
Journal:  Br J Ophthalmol       Date:  2006-03       Impact factor: 4.638

Review 9.  Screening tests for detecting open-angle glaucoma: systematic review and meta-analysis.

Authors:  Graham Mowatt; Jennifer M Burr; Jonathan A Cook; M A Rehman Siddiqui; Craig Ramsay; Cynthia Fraser; Augusto Azuara-Blanco; Jonathan J Deeks
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-07-09       Impact factor: 4.799

10.  Optic disc cupping after optic neuritis evaluated with optic coherence tomography.

Authors:  G Rebolleda; S Noval; I Contreras; F Arnalich-Montiel; J L García-Perez; F J Muñoz-Negrete
Journal:  Eye (Lond)       Date:  2008-04-25       Impact factor: 3.775

View more
  2 in total

1.  Comparison of optic nerve morphology in eyes with glaucoma and eyes with non-arteritic anterior ischemic optic neuropathy by Fourier domain optical coherence tomography.

Authors:  Yuxin Yang; Haitao Zhang; Yitao Yan; Yanling Gui; Tiechui Zhu
Journal:  Exp Ther Med       Date:  2013-05-15       Impact factor: 2.447

2.  Diagnostic ability of macular ganglion cell-inner plexiform layer thickness in glaucoma suspects.

Authors:  Xiaoyu Xu; Hui Xiao; Xinxing Guo; Xiangxi Chen; Linlin Hao; Jingyi Luo; Xing Liu
Journal:  Medicine (Baltimore)       Date:  2017-12       Impact factor: 1.817

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.