Literature DB >> 18612022

How do alternative bearing surfaces influence wear behavior?

Ian C Clarke1, Michael T Manley.   

Abstract

Metal, ceramic, and polyethylene liners represent contemporary bearing choices for total joint replacement. Each has limitations in terms of design, sensitivity to manufacturing, and surgical placement. With polyethylene, larger femoral heads represent a design restriction and a potential wear issue. One side benefit is that polyethylene does not click, squeak, or create stripe wear. The attraction of hard-on-hard bearings (metal-on-metal, ceramic-on-ceramic) is that their typically ultra-low wear alleviates concerns with large femoral head designs. However, hard-on-hard bearings produce stripe wear due to the effects of the rigid liner edge. Slight subluxation (microseparation) during swing phase of gait can result in stripe wear on the ball and liner rim. In addition, high levels of implant wear with vertically placed cups can be anticipated. Currently, only alumina-on-alumina bearings can claim virtually no biologic risk. Thus, the role of laboratory studies is to isolate relevant aspects of performance by cup design and to predict the risk-benefit ratios in patients requiring total hip replacement.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18612022     DOI: 10.5435/00124635-200800001-00018

Source DB:  PubMed          Journal:  J Am Acad Orthop Surg        ISSN: 1067-151X            Impact factor:   3.020


  11 in total

1.  Is metal-on-metal squeaking related to acetabular angle of inclination?

Authors:  Thomas Bernasek; David Fisher; David Dalury; Melissa Levering; Kirk Dimitris
Journal:  Clin Orthop Relat Res       Date:  2011-04-22       Impact factor: 4.176

2.  Wear analysis of chamfered elongated acetabular cup liners.

Authors:  Hsiao-Che Lin; Tzuo-Liang Luo; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2011-12-22       Impact factor: 2.602

3.  Wear degradation of long-term in vivo exposed alumina-on-alumina hip joints: linking nanometer-scale phenomena to macroscopic joint design.

Authors:  Yasuhito Takahashi; Nobuhiko Sugano; Wenliang Zhu; Takashi Nishii; Takashi Sakai; Masaki Takao; Giuseppe Pezzotti
Journal:  J Mater Sci Mater Med       Date:  2011-11-22       Impact factor: 3.896

4.  Wear patterns of, and wear volume formulae for, cylindrically elongated acetabular cup liners.

Authors:  James Shih-Shyn Wu; Shu-Ling Hsu; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2010-04-28       Impact factor: 2.602

5.  Ideal femoral head size in total hip arthroplasty balances stability and volumetric wear.

Authors:  Michael B Cross; Denis Nam; David J Mayman
Journal:  HSS J       Date:  2012-09-13

6.  Using nonlinear finite element models to analyse stress distribution during subluxation and torque required for dislocation of newly developed total hip structure after prosthetic impingement.

Authors:  Wei-Min Chi; Chien-Chung Lin; Ying-Jui Ho; Hsiao-Che Lin; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2017-07-01       Impact factor: 2.602

7.  Effects of design parameters of total hip components on the impingement angle and determination of the preferred liner skirt shape with an adequate oscillation angle.

Authors:  Hsiao-Che Lin; Wei-Min Chi; Ying-Jui Ho; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2012-11-29       Impact factor: 2.602

8.  Incidence of 'squeaking' after ceramic-on-ceramic total hip arthroplasty.

Authors:  Kenny Mai; Christopher Verioti; Kace A Ezzet; Steven N Copp; Richard H Walker; Clifford W Colwell
Journal:  Clin Orthop Relat Res       Date:  2010-02       Impact factor: 4.176

9.  Risk of impingement and third-body abrasion with 28-mm metal-on-metal bearings.

Authors:  Ian C Clarke; Jean-Yves Lazennec; Adrien Brusson; Christina Savisaar; John G Bowsher; Michelle Burgett; Thomas K Donaldson
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

10.  The 2012 Frank Stinchfield Award: Decreasing patient activity with aging: implications for crosslinked polyethylene wear.

Authors:  Andrew K Battenberg; Jeffrey S Hopkins; Andrew D Kupiec; Thomas P Schmalzried
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.