Literature DB >> 22864615

The 2012 Frank Stinchfield Award: Decreasing patient activity with aging: implications for crosslinked polyethylene wear.

Andrew K Battenberg1, Jeffrey S Hopkins, Andrew D Kupiec, Thomas P Schmalzried.   

Abstract

BACKGROUND: Patient activity influences polyethylene wear. However, it is unclear how individual activity changes with patient aging after THA. QUESTIONS/PURPOSES: We quantified changes in individual gait cycles and gait speed, assessed age-related differences in these parameters, and determined their relationship to polyethylene wear.
METHODS: A microprocessor was worn on the ankle to quantify the activity of 14 healthy patients with a well-functioning THA at two time periods: early (within 3.5 years of implantation) and late (10-13 postoperative years). Wear was measured on serial radiographs using edge detection-based software.
RESULTS: Mean activity decreased by 16% from the early to the late period: 2.04 million gait cycles/year to 1.71 million gait cycles/year. Mean gait speed decreased by 9%: 15.4 cycles/minute to 14.0 cycles/minute. The activity of the 10 patients who were younger than 65 years at surgery decreased by 14% (2.34 million gait cycles/year to 2.02 million gait cycles/year), while the four patients 65 years or older at surgery decreased by 28% (1.29 million gait cycles/year to 0.94 million gait cycles/year). Gait speed was 26% slower for patients 65 years or older than for patients younger than 65 years. The mean linear penetration rate decreased by 42% from the first 5 years (early wear rate) to the next 8 years (late wear rate, 5-13 years): 0.043 mm/year to 0.025 mm/year.
CONCLUSIONS: The greatest patient activity and wear occurred during the first 5 years. Walking speed and gait cycles both decreased with aging, resulting in deceasing wear over time.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 22864615      PMCID: PMC3549173          DOI: 10.1007/s11999-012-2497-y

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  14 in total

1.  Step activity monitor: increased accuracy in quantifying ambulatory activity.

Authors:  E F Shepherd; E Toloza; C D McClung; T P Schmalzried
Journal:  J Orthop Res       Date:  1999-09       Impact factor: 3.494

2.  Wear of gamma-crosslinked polyethylene acetabular cups against roughened femoral balls.

Authors:  H McKellop; F W Shen; W DiMaio; J G Lancaster
Journal:  Clin Orthop Relat Res       Date:  1999-12       Impact factor: 4.176

3.  Quantitative assessment of walking activity after total hip or knee replacement.

Authors:  T P Schmalzried; E S Szuszczewicz; M R Northfield; K H Akizuki; R E Frankel; G Belcher; H C Amstutz
Journal:  J Bone Joint Surg Am       Date:  1998-01       Impact factor: 5.284

4.  The long-term results of low-friction arthroplasty of the hip performed as a primary intervention.

Authors:  J Charnley
Journal:  J Bone Joint Surg Br       Date:  1972-02

5.  Activity sampling in the assessment of patients with total joint arthroplasty.

Authors:  Mauricio Silva; Christian D McClung; Mylene A Dela Rosa; Fred J Dorey; Thomas P Schmalzried
Journal:  J Arthroplasty       Date:  2005-06       Impact factor: 4.757

6.  The John Charnley Award. Wear is a function of use, not time.

Authors:  T P Schmalzried; E F Shepherd; F J Dorey; W O Jackson; M dela Rosa; F Fa'vae; H A McKellop; C D McClung; J Martell; J R Moreland; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  2000-12       Impact factor: 4.176

Review 7.  History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene.

Authors:  Steven M Kurtz; Heather A Gawel; Jasmine D Patel
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

Review 8.  A literature review of the association between wear rate and osteolysis in total hip arthroplasty.

Authors:  John H Dumbleton; Michael T Manley; Avram A Edidin
Journal:  J Arthroplasty       Date:  2002-08       Impact factor: 4.757

9.  Incidence and volume of pelvic osteolysis at early follow-up with highly cross-linked and noncross-linked polyethylene.

Authors:  Serena B Leung; Hiroshi Egawa; Adam Stepniewski; Sarah Beykirch; C Anderson Engh; Charles A Engh
Journal:  J Arthroplasty       Date:  2007-07-27       Impact factor: 4.757

10.  Average patient walking activity approaches 2 million cycles per year: pedometers under-record walking activity.

Authors:  Mauricio Silva; Eric F Shepherd; Walter O Jackson; Frederick J Dorey; Thomas P Schmalzried
Journal:  J Arthroplasty       Date:  2002-09       Impact factor: 4.757

View more
  7 in total

1.  Does cyclic stress play a role in highly crosslinked polyethylene oxidation?

Authors:  Francisco Medel; Steven Kurtz; Daniel MacDonald; Francisco Javier Pascual; José Antonio Puértolas
Journal:  Clin Orthop Relat Res       Date:  2015-03       Impact factor: 4.176

2.  Long-term survival of the uncemented Balgrist total hip replacement cup.

Authors:  Jiri Gallo; Jiri Lostak; Katerina Langova
Journal:  Int Orthop       Date:  2013-06-08       Impact factor: 3.075

3.  Patient activity after TKA depends on patient-specific parameters.

Authors:  Cornelia Lützner; Stephan Kirschner; Jörg Lützner
Journal:  Clin Orthop Relat Res       Date:  2014-07-23       Impact factor: 4.176

4.  Wear testing of moderate activities of daily living using in vivo measured knee joint loading.

Authors:  Jörn Reinders; Robert Sonntag; Leo Vot; Christian Gibney; Moritz Nowack; Jan Philippe Kretzer
Journal:  PLoS One       Date:  2015-03-26       Impact factor: 3.240

5.  Retrieval analysis of sequentially annealed highly crosslinked polyethylene used in total hip arthroplasty.

Authors:  Steven M Kurtz; Daniel W MacDonald; Michael A Mont; Javad Parvizi; Arthur L Malkani; William Hozack
Journal:  Clin Orthop Relat Res       Date:  2015-03       Impact factor: 4.176

6.  Total hip arthroplasty following failure of tantalum rod implantation for osteonecrosis of the femoral head with 5- to 10-year follow-up.

Authors:  Qi Cheng; Jin-Long Tang; Jiang-Jiang Gu; Kai-Jin Guo; Wang-Shou Guo; Bai-Liang Wang; Feng-Chao Zhao
Journal:  BMC Musculoskelet Disord       Date:  2018-08-16       Impact factor: 2.362

7.  Influence of Accelerated Aging on the Wear Behavior of Cross-Linked Polyethylene Liners-A Hip Simulator Study.

Authors:  Rebecca H Dammer; Carmen Zietz; Jörn Reinders; Michael Teske; Rainer Bader
Journal:  J Clin Med       Date:  2022-08-01       Impact factor: 4.964

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.