Literature DB >> 18606748

Dosimetry of the cone beam computed tomography Veraviewepocs 3D compared with the 3D Accuitomo in different fields of view.

E Hirsch1, U Wolf, F Heinicke, M A G Silva.   

Abstract

OBJECTIVES: This study compares tissue-absorbed and effective doses of the cone beam CT (CBCT) units, the Veraviewepocs 3D and the 3D Accuitomo, in different protocols.
METHODS: The absorbed organ doses were measured using an anthropomorphic phantom loaded with thermoluminescent dosemeters (TLDs) in 16 sensitive organ sites. Both CBCT units were deployed with different fields of view (FOVs): 3D Accuitomo using two protocols (anterior 4 x 4 cm scan and anterior 6 x 6 cm scan) and Veraviewepocs 3D using three protocols (anterior 4 x 4 cm scan, anterior 8 x 4 cm scan and panoramic + anterior 4 x 4 cm). Equivalent and effective doses were then calculated, the latter based on the International Commission on Radiological Protection's (ICRP) 2005 recommendations.
RESULTS: The lowest effective dose was observed for the 3D Accuitomo 4 x 4 cm (20.02 microSv), the highest for the 3D Accuitomo 6 x 6 cm (43.27 microSv). The effective dose recorded for Veraviewepocs 3D was 39.92 microSv for the 8 x 4 cm scan, 30.92 microSv for the 4 x 4 cm scan and 29.78 microSv for the panoramic + 4 x 4 cm scan protocol.
CONCLUSIONS: The radiation doses delivered by both machines were in comparable ranges when using 4 x 4 cm FOV. A smaller FOV should be used for dental images, whereas a larger FOV should be restricted to cases in which a wider view is required.

Mesh:

Year:  2008        PMID: 18606748     DOI: 10.1259/dmfr/23424132

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  28 in total

1.  Optimization of cone beam CT exposure for pre-surgical evaluation of the implant site.

Authors:  A Dawood; J Brown; V Sauret-Jackson; S Purkayastha
Journal:  Dentomaxillofac Radiol       Date:  2011-12-19       Impact factor: 2.419

2.  Digital method for quantification of circumferential periodontal bone level using cone beam CT.

Authors:  Jonathan Fleiner; Christian Hannig; Dirk Schulze; Andres Stricker; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2012-03-21       Impact factor: 3.573

3.  Dose distribution for dental cone beam CT and its implication for defining a dose index.

Authors:  R Pauwels; C Theodorakou; A Walker; H Bosmans; R Jacobs; K Horner; R Bogaerts
Journal:  Dentomaxillofac Radiol       Date:  2012-06-29       Impact factor: 2.419

4.  Accuracy of CBCT measurements of a human skull.

Authors:  Kivanç Kamburoğlu; Eray Kolsuz; Hakan Kurt; Cenk Kiliç; Tuncer Özen; Candan Semra Paksoy
Journal:  J Digit Imaging       Date:  2011-10       Impact factor: 4.056

Review 5.  Modern dental imaging: a review of the current technology and clinical applications in dental practice.

Authors:  Bart Vandenberghe; Reinhilde Jacobs; Hilde Bosmans
Journal:  Eur Radiol       Date:  2010-06-11       Impact factor: 5.315

6.  A comparative study of the effective radiation doses from cone beam computed tomography and plain radiography for sialography.

Authors:  F Jadu; M J Yaffe; E W N Lam
Journal:  Dentomaxillofac Radiol       Date:  2010-07       Impact factor: 2.419

7.  Estimation of paediatric organ and effective doses from dental cone beam CT using anthropomorphic phantoms.

Authors:  C Theodorakou; A Walker; K Horner; R Pauwels; R Bogaerts; R Jacobs
Journal:  Br J Radiol       Date:  2012-02       Impact factor: 3.039

8.  Accuracy of chemically created periapical lesion measurements using limited cone beam computed tomography.

Authors:  K Kamburoğlu; C Kiliç; T Ozen; S Horasan
Journal:  Dentomaxillofac Radiol       Date:  2010-02       Impact factor: 2.419

Review 9.  Clinical guidelines for dental cone-beam computed tomography.

Authors:  Takafumi Hayashi; Yoshinori Arai; Toru Chikui; Sachiko Hayashi-Sakai; Kazuya Honda; Hiroko Indo; Taisuke Kawai; Kaoru Kobayashi; Shumei Murakami; Masako Nagasawa; Munetaka Naitoh; Eiji Nakayama; Yutaka Nikkuni; Hideyoshi Nishiyama; Noriaki Shoji; Shigeaki Suenaga; Ray Tanaka
Journal:  Oral Radiol       Date:  2018-01-11       Impact factor: 1.852

10.  Use of cone beam computed tomography in endodontics.

Authors:  William C Scarfe; Martin D Levin; David Gane; Allan G Farman
Journal:  Int J Dent       Date:  2010-03-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.