Effect of the flow field of mechanical bileaflet mitral prostheses on valve closing.

Toshinosuke Akutsu1, Ryota Imai, Yuuki Deguchi.   

Abstract

Antianatomically installed Jyros (JR) and ATS valves were compared with the St. Jude Medical (SJM) valve in the mitral position to study the effects of valve design on the downstream flow field and associated closing sounds using a particle image velocimetry (PIV) method utilizing a high-speed video flow visualization technique to map the velocity field and sound measurement to confirm claims by the manufacturer. Based on the experimental data, the following general conclusions can be made: in the velocity field directly below the mitral valve, where distinct characteristic differences in valve design can be seen, symmetrical twin circulations were observed because of the divergent nature of the flow generated by the two inclined half-disks installed in the antianatomical orientation; the SJM valve, which produced central downward circulation, is contrasted to the two other valves, which produced peripheral downward circulation. These differences may play an important role in the closing behavior of the valve leaflets, thus affecting the generation of the valve closing sound.

Mesh:

Year:  2005        PMID: 16235033     DOI: 10.1007/s10047-005-0297-9

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  5 in total

1.  THE ANATOMY OF THE MITRAL VALVE AND ITS ASSOCIATED STRUCTURES.

Authors:  L A DUPLESSIS; P MARCHAND
Journal:  Thorax       Date:  1964-05       Impact factor: 9.139

2.  Surgical correction of aortic insufficiency.

Authors:  C A HUFNAGEL; W P HARVEY; P J RABIL; T F McDERMOTT
Journal:  Surgery       Date:  1954-05       Impact factor: 3.982

3.  Unsteady fluid dynamics of several mechanical prosthetic heart valves using a two component laser Doppler anemometer system.

Authors:  T Akutsu; V J Modi
Journal:  Artif Organs       Date:  1997-10       Impact factor: 3.094

4.  An artificial arterial system for pumping hearts.

Authors:  N Westerhof; G Elzinga; P Sipkema
Journal:  J Appl Physiol       Date:  1971-11       Impact factor: 3.531

5.  A 5 1/2 year experience with the St. Jude Medical cardiac valve prosthesis. Early and late results of 737 valve replacements in 671 patients.

Authors:  E M Baudet; C C Oca; X F Roques; M N Laborde; A S Hafez; M A Collot; I M Ghidoni
Journal:  J Thorac Cardiovasc Surg       Date:  1985-07       Impact factor: 5.209

  5 in total
  3 in total

1.  Correlation between ventricular flow field and valve closing sound of mechanical mitral prostheses.

Authors:  Toshinosuke Akutsu; Ryota Imai; Jun Saito; Tomoyuki Suzuki
Journal:  J Artif Organs       Date:  2008-07-06       Impact factor: 1.731

2.  Energy dynamics of the intraventricular vortex after mitral valve surgery.

Authors:  Kouki Nakashima; Keiichi Itatani; Tadashi Kitamura; Norihiko Oka; Tetsuya Horai; Shohei Miyazaki; Masaki Nie; Kagami Miyaji
Journal:  Heart Vessels       Date:  2017-04-07       Impact factor: 2.037

3.  Role of Computational Simulations in Heart Valve Dynamics and Design of Valvular Prostheses.

Authors:  Krishnan B Chandran
Journal:  Cardiovasc Eng Technol       Date:  2010-03       Impact factor: 2.495

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.