Impact magnitudes applied by surgeons and their importance when applying the femoral head onto the Morse taper for total hip arthroplasty.

Jake P Heiney1, Suneel Battula, Gregory A Vrabec, Anand Parikh, Rebecca Blice, Andrew J Schoenfeld, Glenn O Njus.   

Abstract

INTRODUCTION: This study was designed to test whether the number of impacts, the experience of the surgeon or impact force made significant difference in pull off forces.
MATERIALS AND METHODS: The forces applied by 10 orthopaedic surgeons (five residents and five attending staff) to impact the femoral head onto the trunnion of a femoral component were recorded. The resultant forces were then divided into four energy levels and compared to determine if the number of impacts would make a difference in pull off strength.
RESULTS: No significant differences existed between the resident versus attending groups in magnitude of force applied. Through ANOVA testing, it was found that at each of the energy levels, multiple blows demonstrated a significant pull off strength difference compared to a single blow. Increased pull off force was also noted when the magnitude of force of the applied blows was increased.
CONCLUSION: We recommend at least two firm, axially aligned blows to impact the femoral head onto the trunnion intra-operatively.

Entities:  

Mesh:

Year:  2008        PMID: 18600337     DOI: 10.1007/s00402-008-0660-4

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  11 in total

1.  CORR Insights(®): High Risk of Failure With Bimodular Femoral Components in THA.

Authors:  Nicholas J Giori
Journal:  Clin Orthop Relat Res       Date:  2015-09-25       Impact factor: 4.176

2.  Stability and trunnion wear potential in large-diameter metal-on-metal total hips: a finite element analysis.

Authors:  Jacob M Elkins; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

3.  Contact conditions for total hip head-neck modular taper junctions with microgrooved stem tapers.

Authors:  Maren Bechstedt; Jonathan A Gustafson; Steven P Mell; Julian Gührs; Michael M Morlock; Brett R Levine; Hannah J Lundberg
Journal:  J Biomech       Date:  2020-02-25       Impact factor: 2.712

Review 4.  What Surgeons Need to Know About Adverse Local Tissue Reaction in Total Hip Arthroplasty.

Authors:  Deborah J Hall; Robin Pourzal; Joshua J Jacobs
Journal:  J Arthroplasty       Date:  2020-01-15       Impact factor: 4.757

5.  The effect of manufacturing tolerances on the mechanical environment of taper junctions in modular TKR.

Authors:  Kyle Snethen; Jorge Hernandez; Melinda Harman
Journal:  J Mech Behav Biomed Mater       Date:  2019-04-18

6.  Fixation strength of taper connection at head-neck junction in retrieved carbon fiber-reinforced PEEK hip stems.

Authors:  Ichiro Nakahara; Masaki Takao; Shunichi Bandoh; Nobuhiko Sugano
Journal:  J Artif Organs       Date:  2014-09-05       Impact factor: 1.731

7.  Large-diameter total hip arthroplasty modular heads require greater assembly forces for initial stability.

Authors:  A R MacLeod; N P T Sullivan; M R Whitehouse; H S Gill
Journal:  Bone Joint Res       Date:  2016-08       Impact factor: 5.853

Review 8.  What the Surgeon Can Do to Reduce the Risk of Trunnionosis in Hip Arthroplasty: Recommendations from the Literature.

Authors:  Claude B Rieker; Peter Wahl
Journal:  Materials (Basel)       Date:  2020-04-21       Impact factor: 3.623

9.  Influence of Different Damage Patterns of the Stem Taper on Fixation and Fracture Strength of Ceramic Ball Heads for Total Hip Replacement.

Authors:  Danny Vogel; Jessica Hembus; Mario Jackszis; Vera Bolte; Rainer Bader
Journal:  Biomed Res Int       Date:  2020-05-13       Impact factor: 3.411

10.  Importance of surgical assembly technique on the engagement of 12/14 modular tapers.

Authors:  A Wade; F Webster; A R Beadling; M G Bryant
Journal:  Proc Inst Mech Eng H       Date:  2021-10-25       Impact factor: 1.617

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.