Literature DB >> 18590854

Effect of suture material and bone quality on the mechanical properties of zone I flexor tendon-bone reattachment with bone anchors.

Hironori Matsuzaki1, Melissa A Zaegel, Richard H Gelberman, Matthew J Silva.   

Abstract

PURPOSE: To compare the initial biomechanical properties of zone I flexor tendon to bone repairs performed using pull-out and anchor techniques and to investigate the effect of bone quality and suture materials on the strength of anchor repairs.
METHODS: Using computed tomography, we measured bone mineral density and cortical thickness of the distal phalanx of 60 cadaver fingers (mean age, 77 years). Flexor digitorum profundus tendons were then transected at their insertion sites and repaired using a 4-strand grasping suture and either pull-out or anchor fixation. For pull-out repair (n = 20), the suture strands (Supramid 3-0; S. Jackson, Inc., Alexandria, VA) were passed through the distal phalanx and tied over a dorsal button. For anchor repair, 2 bone anchors were inserted into the distal phalanx, and tendons were grasped using either Supramid (n = 21), Ethibond (Ethicon, Inc., Somerville, NJ; n = 10), or FiberWire suture (Arthrex Inc., Naples, FL; n = 9) (all 3-0). Mechanical properties of the repaired tendon-bone constructs were determined in linear, load-to-failure loading and correlated with bone characteristics.
RESULTS: The FiberWire-anchor repair group had the best combination of mechanical properties, with ultimate force to failure no different from the pull-out repairs but with greater stiffness and reduced displacement. Pull-out suture repairs had significantly higher ultimate force-to-failure values than did Ethibond-anchor and Supramid-anchor repairs (p < .01). However, pull-out repairs had significantly reduced stiffness and greater displacement at 20 N force than did anchor repairs from all groups (p < .05). Both bone mineral density and cortical thickness correlated significantly with ultimate force (p < .01). Almost all anchors pulled out for bone mineral density below 420 mg/cm(3) or cortical thickness less than 0.31 mm, which occurred only for specimens aged greater than 75 years.
CONCLUSIONS: The mechanical properties of the double Mitek bone anchors were sensitive to both suture material and bone quality. FiberWire-anchor repairs provided the best combination of mechanical properties. Pull-out suture repairs had good strength but poor stiffness. Anchor fixation may be contraindicated in patients greater than 75 years because of poor bone quality.

Entities:  

Mesh:

Year:  2008        PMID: 18590854      PMCID: PMC4435539          DOI: 10.1016/j.jhsa.2008.01.025

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  17 in total

1.  Bone suture anchors versus the pullout button for repair of distal profundus tendon injuries: a comparison of strength in human cadaveric hands.

Authors:  M Brustein; J Pellegrini; J Choueka; H Heminger; D Mass
Journal:  J Hand Surg Am       Date:  2001-05       Impact factor: 2.230

2.  Repair of flexor digitorum profundus tendon avulsions from bone: an ex vivo biomechanical analysis.

Authors:  Martin I Boyer; Konstantinos Ditsios; Richard H Gelberman; Fraser Leversedge; Matthew Silva
Journal:  J Hand Surg Am       Date:  2002-07       Impact factor: 2.230

3.  Anchor design and bone mineral density affect the pull-out strength of suture anchors in rotator cuff repair: which anchors are best to use in patients with low bone quality?

Authors:  Markus J Tingart; Maria Apreleva; Janne Lehtinen; David Zurakowski; Jon J P Warner
Journal:  Am J Sports Med       Date:  2004-07-20       Impact factor: 6.202

4.  Flexor tendon forces: in vivo measurements.

Authors:  F Schuind; M Garcia-Elias; W P Cooney; K N An
Journal:  J Hand Surg Am       Date:  1992-03       Impact factor: 2.230

5.  Supplementary core sutures increase resistance to gapping for flexor digitorum profundus tendon to bone surface repair - an in vitro biomechanical analysis.

Authors:  N Kusano; M A Zaegel; J D Placzek; R H Gelberman; M J Silva
Journal:  J Hand Surg Br       Date:  2005-04-08

6.  The effects of multiple-strand suture techniques on the tensile properties of repair of the flexor digitorum profundus tendon to bone.

Authors:  M J Silva; S B Hollstien; A H Fayazi; P Adler; R H Gelberman; M I Boyer
Journal:  J Bone Joint Surg Am       Date:  1998-10       Impact factor: 5.284

7.  The Mitek Mini G2 suture anchor: biomechanical analysis of use in the hand.

Authors:  B D Buch; P Innis; M A McClinton; Y Kotani
Journal:  J Hand Surg Am       Date:  1995-09       Impact factor: 2.230

8.  Direct and computed tomography thickness measurements of the human, lumbar vertebral shell and endplate.

Authors:  M J Silva; C Wang; T M Keaveny; W C Hayes
Journal:  Bone       Date:  1994 Jul-Aug       Impact factor: 4.398

9.  Avulsions of the flexor digitorum profundus.

Authors:  J P Leddy
Journal:  Hand Clin       Date:  1985-02       Impact factor: 1.907

10.  A biomechanical analysis of suture materials and their influence on a four-strand flexor tendon repair.

Authors:  Tom M Lawrence; Tim R C Davis
Journal:  J Hand Surg Am       Date:  2005-07       Impact factor: 2.230

View more
  12 in total

1.  Biomechanical Comparison of Flexor Digitorum Profundus Avulsion Repair.

Authors:  Jill G Putnam; Damon Adamany
Journal:  J Wrist Surg       Date:  2019-04-22

2.  Mechanical properties of the flexor digitorum profundus tendon attachment.

Authors:  Jerrod J Felder; Loredana M Guseila; Archana Saranathan; Timothy J Shary; Steven B Lippitt; John J Elias
Journal:  J Hand Microsurg       Date:  2013-06-02

3.  Surgical Sutures with Porous Sheaths for the Sustained Release of Growth Factors.

Authors:  Jianhua Li; Stephen W Linderman; Chunlei Zhu; Hong Liu; Stavros Thomopoulos; Younan Xia
Journal:  Adv Mater       Date:  2016-04-05       Impact factor: 30.849

4.  Improvement of flexor tendon reconstruction with carbodiimide-derivatized hyaluronic acid and gelatin-modified intrasynovial allografts: study of a primary repair failure model.

Authors:  Chunfeng Zhao; Yu-Long Sun; Jun Ikeda; Ramona L Kirk; Andrew R Thoreson; Steven L Moran; Kai-Nan An; Peter C Amadio
Journal:  J Bone Joint Surg Am       Date:  2010-12-01       Impact factor: 5.284

5.  The effect of the trabecular microstructure on the pullout strength of suture anchors.

Authors:  Christopher M Yakacki; Mariya Poukalova; Robert E Guldberg; Angela Lin; Minn Saing; Scott Gillogly; Ken Gall
Journal:  J Biomech       Date:  2010-04-18       Impact factor: 2.712

6.  Four Anchor Repair of Jersey Finger.

Authors:  Adrian C Kong; Alex Kitto; Dimas E Pineda; Roberto A Miki; Daniel T Alfonso; Israel Alfonso
Journal:  Iowa Orthop J       Date:  2021-12

7.  Comparison of Transverse Intraosseous Loop Technique and Pull Out Suture for Reinsertion of the Flexor Digitorum Profundus tendon. A Retrospective Study.

Authors:  István Zoltán Rigó; Magne Røkkum
Journal:  J Hand Microsurg       Date:  2013-07-31

8.  Distal attachment of flexor tendon allograft: a biomechanical study of different reconstruction techniques in human cadaver hands.

Authors:  Zhuang Wei; Andrew R Thoreson; Peter C Amadio; Kai-Nan An; Chunfeng Zhao
Journal:  J Orthop Res       Date:  2013-06-10       Impact factor: 3.494

9.  Comparison of an all-inside suture technique with traditional pull-out suture and suture anchor repair techniques for flexor digitorum profundus attachment to bone.

Authors:  Jennifer Y Chu; Tony Chen; Hani A Awad; John Elfar; Warren C Hammert
Journal:  J Hand Surg Am       Date:  2013-04-09       Impact factor: 2.230

Review 10.  Sports-related wrist and hand injuries: a review.

Authors:  Daniel M Avery; Craig M Rodner; Cory M Edgar
Journal:  J Orthop Surg Res       Date:  2016-09-16       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.