Literature DB >> 24426675

Mechanical properties of the flexor digitorum profundus tendon attachment.

Jerrod J Felder1, Loredana M Guseila1, Archana Saranathan1, Timothy J Shary1, Steven B Lippitt1, John J Elias2.   

Abstract

The current study was performed to determine the strength and rigidity of the intact flexor digitorum profundus (FDP) tendon attachment and compare the rigidity at the attachment site to the rigidity within a more proximal part of the tendon. Eight cadaveric index fingers were tested to failure of the FDP tendon. Lines were drawn on each tendon with India ink stain at the position of the attachment to bone and 5 mm and 10 mm proximally. Each test was recorded using a high resolution video camera. A minimum of six images per test were used for analysis of tissue deformation. The centroid of each line was computationally identified to characterize the deformation of the tendon between the lines. Force vs. deformation curves were generated for the 5 mm region representing the tendon attachment and the 5 mm region adjacent to the attachment. Stiffness measurements were generated for each curve, and normalized by the initial length to determine the rigidity. The failure strength ranged from 263 N to 548 N, with rigidity values ranging from 2201 N/(mm/mm) to 8714 N/(mm/mm) and from 3459 N/(mm/mm) to 6414 N/(mm/mm) for the attachment and the tendon proximal to the attachment, respectively. The rigidity did not vary significantly between the attachment and proximal tendon based on a Wilcoxon signed rank test (p = 0.2). The measured strength and rigidity establish biomechanical properties for the FDP tendon attachment to bone.

Entities:  

Keywords:  Flexor digitorum profundus tendon; Stiffness; Strength; Tendon attachment

Year:  2013        PMID: 24426675      PMCID: PMC3827651          DOI: 10.1007/s12593-013-0097-z

Source DB:  PubMed          Journal:  J Hand Microsurg        ISSN: 0974-3227


  23 in total

1.  Primary flexor tendon repair in zone 1.

Authors:  N S Moiemen; D Elliot
Journal:  J Hand Surg Br       Date:  2000-02

2.  The strength of the profundus tendon insertion.

Authors:  C E Holden; M D Northmore-Ball
Journal:  Hand       Date:  1975-10

3.  Characterizing local collagen fiber re-alignment and crimp behavior throughout mechanical testing in a mature mouse supraspinatus tendon model.

Authors:  Kristin S Miller; Brianne K Connizzo; Elizabeth Feeney; Louis J Soslowsky
Journal:  J Biomech       Date:  2012-07-08       Impact factor: 2.712

4.  Supplementary core sutures increase resistance to gapping for flexor digitorum profundus tendon to bone surface repair - an in vitro biomechanical analysis.

Authors:  N Kusano; M A Zaegel; J D Placzek; R H Gelberman; M J Silva
Journal:  J Hand Surg Br       Date:  2005-04-08

Review 5.  Tendon avulsion injuries of the distal phalanx.

Authors:  Harrison G Tuttle; Scott P Olvey; Peter J Stern
Journal:  Clin Orthop Relat Res       Date:  2006-04       Impact factor: 4.176

6.  Effect of suture material and bone quality on the mechanical properties of zone I flexor tendon-bone reattachment with bone anchors.

Authors:  Hironori Matsuzaki; Melissa A Zaegel; Richard H Gelberman; Matthew J Silva
Journal:  J Hand Surg Am       Date:  2008 May-Jun       Impact factor: 2.230

7.  The effects of multiple-strand suture techniques on the tensile properties of repair of the flexor digitorum profundus tendon to bone.

Authors:  M J Silva; S B Hollstien; A H Fayazi; P Adler; R H Gelberman; M I Boyer
Journal:  J Bone Joint Surg Am       Date:  1998-10       Impact factor: 5.284

8.  Tensile testing of bone over a wide range of strain rates: effects of strain rate, microstructure and density.

Authors:  T M Wright; W C Hayes
Journal:  Med Biol Eng       Date:  1976-11

9.  A new optical system for the determination of deformations and strains: calibration characteristics and experimental results.

Authors:  K A Derwin; L J Soslowsky; W D Green; S H Elder
Journal:  J Biomech       Date:  1994-10       Impact factor: 2.712

10.  The mechanical properties of human flexor tendons in relation to artificial tendons.

Authors:  D J Pring; A A Amis; R R Coombs
Journal:  J Hand Surg Br       Date:  1985-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.