Literature DB >> 31402995

Biomechanical Comparison of Flexor Digitorum Profundus Avulsion Repair.

Jill G Putnam1, Damon Adamany2.   

Abstract

Purpose  Multiple repair techniques have been investigated for flexor digitorum profundus (FDP) tendon avulsions. The purpose of this study is to compare the biomechanical characteristics of a new fully threaded titanium suture anchor with previously examined fixation techniques. Methods  Repair of FDP tendon avulsions was performed in 18 fresh-frozen cadavers using one of three implants: Nano Corkscrew FT 1.7 mm suture anchor (Group 1; Arthrex, Inc., Naples, FL; n  = 6), Mitek Micro 1.3 mm suture anchor (Group 2; Mitek Surgical Products, Westwood, MA; n  = 6), or pullout suture button fixation (Group 3; n  = 6). Constructs were preloaded before testing load to failure. For each trial, elongation at 20 N and maximum load, mean load to failure, stiffness, and failure mechanism were recorded. Results  Load to failure occurred in all trials. Mean load to failure was significantly greater for Group 1 (61.6 ± 18.9 N) compared to Group 2 (42.5 ± 4.2 N; p  < 0.05) and Group 3 (41.6 N ± 8.0 N; p  < 0.05). Stiffness was significantly greater in Groups 1 and 2 compared to Group 3 (6.9 ± 2.2 N/mm vs. 6.1 ± 0.8 N/mm vs. 3.1 N/mm ± 0.5 N/mm, respectively, p  < 0.01). Mechanism of failure differed between the groups: Group 1 broke at the anchor in two trials and tore through the tendon in three trials, Group 2's suture universally broke at the anchor, and Group 3's trials mainly failed at the button. Conclusions  The Nano Corkscrew anchor (Group 1) has a significantly higher load to failure when compared with the other techniques. The higher load to failure of the corkscrew anchor provides a secure method for flexor tendon repair in zone I. Clinical Relevance  A fully threaded titanium suture anchor used for FDP tendon avulsion injuries is likely to withstand early active range of motion protocols.

Entities:  

Keywords:  avulsion; biomechanical; flexor; repair; tendon

Year:  2019        PMID: 31402995      PMCID: PMC6685782          DOI: 10.1055/s-0039-1685470

Source DB:  PubMed          Journal:  J Wrist Surg        ISSN: 2163-3916


  21 in total

1.  Primary flexor tendon repair in zone 1.

Authors:  N S Moiemen; D Elliot
Journal:  J Hand Surg Br       Date:  2000-02

2.  Bone suture anchors versus the pullout button for repair of distal profundus tendon injuries: a comparison of strength in human cadaveric hands.

Authors:  M Brustein; J Pellegrini; J Choueka; H Heminger; D Mass
Journal:  J Hand Surg Am       Date:  2001-05       Impact factor: 2.230

3.  Pullout strength of suture anchors used in rotator cuff repair.

Authors:  Markus J Tingart; Maria Apreleva; David Zurakowski; Jon J P Warner
Journal:  J Bone Joint Surg Am       Date:  2003-11       Impact factor: 5.284

4.  Flexor tendon forces: in vivo measurements.

Authors:  F Schuind; M Garcia-Elias; W P Cooney; K N An
Journal:  J Hand Surg Am       Date:  1992-03       Impact factor: 2.230

5.  Effect of suture material and bone quality on the mechanical properties of zone I flexor tendon-bone reattachment with bone anchors.

Authors:  Hironori Matsuzaki; Melissa A Zaegel; Richard H Gelberman; Matthew J Silva
Journal:  J Hand Surg Am       Date:  2008 May-Jun       Impact factor: 2.230

6.  Repair of flexor digitorum profundus to distal phalanx: a biomechanical evaluation of four techniques.

Authors:  Steve K Lee; Marc Fajardo; George Kardashian; Jason Klein; Peter Tsai; Dimitrios Christoforou
Journal:  J Hand Surg Am       Date:  2011-08-27       Impact factor: 2.230

7.  The button-over-nail technique for Zone I flexor tendon injuries.

Authors:  A S C Bidwai; L Feldberg
Journal:  Hand Surg       Date:  2012

8.  Cyclic loading biomechanical analysis of the pullout strengths of rotator cuff and glenoid anchors: 2013 update.

Authors:  F Alan Barber; Morley A Herbert
Journal:  Arthroscopy       Date:  2013-04-02       Impact factor: 4.772

Review 9.  Avulsion injuries of the flexor digitorum profundus tendon.

Authors:  David E Ruchelsman; Dimitrios Christoforou; Bradley Wasserman; Steve K Lee; Michael E Rettig
Journal:  J Am Acad Orthop Surg       Date:  2011-03       Impact factor: 3.020

10.  Comparison of pullout button versus suture anchor for zone I flexor tendon repair.

Authors:  Wren V McCallister; Heidi C Ambrose; Leonid I Katolik; Thomas E Trumble
Journal:  J Hand Surg Am       Date:  2006-02       Impact factor: 2.230

View more
  1 in total

1.  Hook Plate as a Treatment for Flexor Digitorum Profundus Avulsion Types II and III.

Authors:  Manel Fa-Binefa; Gonzalo Pérez-López; Marta Almenara; Claudia Lamas
Journal:  Hand (N Y)       Date:  2020-09-16
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.