Literature DB >> 23578439

Comparison of an all-inside suture technique with traditional pull-out suture and suture anchor repair techniques for flexor digitorum profundus attachment to bone.

Jennifer Y Chu1, Tony Chen, Hani A Awad, John Elfar, Warren C Hammert.   

Abstract

PURPOSE: One goal in repairing zone 1 flexor digitorum profundus (FDP) injuries is to create a tendon-bone construct strong enough to allow early rehabilitation while minimizing morbidity. This study compares an all-inside suture repair technique biomechanically with pull-out suture and double-suture anchor repairs.
METHODS: Repairs were performed on 30 cadaver fingers. In all-inside suture repairs (n = 8), the FDP tendon was attached to bone with two 3-0 Ethibond sutures and tied over the dorsal aspect of distal phalanx. Pull-out suture repairs (n = 8) were performed with 2-0 Prolene suture and tied over a dorsal button. There were 2 suture anchor repair groups: Arthrex Micro Corkscrew anchors preloaded with 2-0 FiberWire suture (n = 7) and Depuy Micro Mitek anchors preloaded with 3-0 Orthocord suture (n = 7). Repair constructs were tested using a servohydraulic materials testing system and loaded until the repair lost 75% of its strength.
RESULTS: There were no statistically significant differences in tensile stiffness, ultimate load, or work to failure between the repairs. Failure mode was suture stretch and gap formation greater than 2 mm at the repair site for all pull-out suture repairs and for 7 of 8 all-inside suture repairs. Two of the Arthrex Micro Corkscrew repairs and 5 of the Depuy Micro Mitek repairs failed by anchor pull-out.
CONCLUSIONS: This cadaveric biomechanical study showed no difference in tensile stiffness, ultimate load, and work to failures between an all-inside suture repair technique for zone 1 FDP repairs and previously described pull-out suture and suture anchor repair techniques. The all-inside suture technique also has the advantages of avoiding an external button and the cost of anchors. Therefore, it should be considered as an alternative to other techniques. CLINICAL RELEVANCE: This study introduces a new FDP reattachment technique that avoids some of the shortcomings of current techniques.
Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23578439      PMCID: PMC4426886          DOI: 10.1016/j.jhsa.2013.02.015

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  12 in total

1.  The Mantero flexor tendon repair in zone 1.

Authors:  D Guinard; F Montanier; D Thomas; D Corcella; F Moutet
Journal:  J Hand Surg Br       Date:  1999-04

2.  Bone suture anchors versus the pullout button for repair of distal profundus tendon injuries: a comparison of strength in human cadaveric hands.

Authors:  M Brustein; J Pellegrini; J Choueka; H Heminger; D Mass
Journal:  J Hand Surg Am       Date:  2001-05       Impact factor: 2.230

3.  Effect of suture material on gap formation and failure in type 1 FDP avulsion repairs in a cadaver model.

Authors:  F B Schreuder; P J Scougall; E Puchert; F Vizesi; W R Walsh
Journal:  Clin Biomech (Bristol, Avon)       Date:  2006-02-08       Impact factor: 2.063

4.  The morbidity of the button-over-nail technique for zone 1 flexor tendon repairs. Should we still be using this technique?

Authors:  N Kang; D Marsh; D Dewar
Journal:  J Hand Surg Eur Vol       Date:  2008-10

5.  Effect of suture material and bone quality on the mechanical properties of zone I flexor tendon-bone reattachment with bone anchors.

Authors:  Hironori Matsuzaki; Melissa A Zaegel; Richard H Gelberman; Matthew J Silva
Journal:  J Hand Surg Am       Date:  2008 May-Jun       Impact factor: 2.230

6.  The effects of multiple-strand suture techniques on the tensile properties of repair of the flexor digitorum profundus tendon to bone.

Authors:  M J Silva; S B Hollstien; A H Fayazi; P Adler; R H Gelberman; M I Boyer
Journal:  J Bone Joint Surg Am       Date:  1998-10       Impact factor: 5.284

7.  Flexor digitorum profundus tendon-to-bone repair: an ex vivo biomechanical analysis of 3 pullout suture techniques.

Authors:  M J Silva; S B Hollstien; M D Brodt; M I Boyer; A M Tetro; R H Gelberman
Journal:  J Hand Surg Am       Date:  1998-01       Impact factor: 2.230

8.  Optimizing independent finger flexion with zone V flexor repairs using the Massachusetts General Hospital flexor tenorrhaphy and early protected active motion.

Authors:  Bradon J Wilhelmi; Robert H Kang; David J Wages; W P Andrew Lee; James W May
Journal:  J Hand Surg Am       Date:  2005-03       Impact factor: 2.230

9.  A biomechanical analysis of suture materials and their influence on a four-strand flexor tendon repair.

Authors:  Tom M Lawrence; Tim R C Davis
Journal:  J Hand Surg Am       Date:  2005-07       Impact factor: 2.230

10.  Comparison of pullout button versus suture anchor for zone I flexor tendon repair.

Authors:  Wren V McCallister; Heidi C Ambrose; Leonid I Katolik; Thomas E Trumble
Journal:  J Hand Surg Am       Date:  2006-02       Impact factor: 2.230

View more
  4 in total

1.  Biomechanical Comparison of Flexor Digitorum Profundus Avulsion Repair.

Authors:  Jill G Putnam; Damon Adamany
Journal:  J Wrist Surg       Date:  2019-04-22

Review 2.  A review of mallet finger and jersey finger injuries in the athlete.

Authors:  Abdo Bachoura; Alex J Ferikes; John D Lubahn
Journal:  Curr Rev Musculoskelet Med       Date:  2017-03

3.  Four Anchor Repair of Jersey Finger.

Authors:  Adrian C Kong; Alex Kitto; Dimas E Pineda; Roberto A Miki; Daniel T Alfonso; Israel Alfonso
Journal:  Iowa Orthop J       Date:  2021-12

Review 4.  Sports-related wrist and hand injuries: a review.

Authors:  Daniel M Avery; Craig M Rodner; Cory M Edgar
Journal:  J Orthop Surg Res       Date:  2016-09-16       Impact factor: 2.359

  4 in total