Literature DB >> 18581340

Improved slice selection for R2* mapping during cryoablation with eddy current compensation.

Aiming Lu1, Bruce L Daniel, John M Pauly, Kim Butts Pauly.   

Abstract

PURPOSE: To improve the slice profile and image quality of R2* mapping in the iceball during cryoablation with ultrashort echo time (UTE) imaging by compensating for eddy currents induced by the selective gradient when half-pulse radiofrequency (RF) excitation is employed to achieve UTEs.
MATERIALS AND METHODS: A method to measure both B0 and linear eddy currents simultaneously is first presented. This is done with a least-square fitting process on calibration data collected on a phantom. Eddy currents during excitation are compensated by redesigning the RF pulse and the selective gradient accordingly, while that resultant from the readout gradient are compensated for during image reconstruction. In vivo data were obtained continuously during the cryoablation experiments to calculate the R2* values in the iceball and to correlate them with the freezing process.
RESULTS: Image quality degradation due to eddy currents is significantly reduced with the proposed approaches. R2* maps of iceball throughout the cryoablation experiments were achieved with improved quality.
CONCLUSION: The proposed approaches are effective for compensating eddy currents during half-pulse RF excitation as well as readout. TEs as short as 100 microsec were obtained, allowing R2* maps to be obtained from frozen tissues with improved quality. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2008        PMID: 18581340      PMCID: PMC2632801          DOI: 10.1002/jmri.21396

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  13 in total

1.  Temperature mapping of frozen tissue using eddy current compensated half excitation RF pulses.

Authors:  J P Wansapura; B L Daniel; J Pauly; K Butts
Journal:  Magn Reson Med       Date:  2001-11       Impact factor: 4.668

2.  Temperature quantitation and mapping of frozen tissue.

Authors:  K Butts; J Sinclair; B L Daniel; J Wansapura; J M Pauly
Journal:  J Magn Reson Imaging       Date:  2001-01       Impact factor: 4.813

Review 3.  Magnetic resonance: an introduction to ultrashort TE (UTE) imaging.

Authors:  Matthew D Robson; Peter D Gatehouse; Mark Bydder; Graeme M Bydder
Journal:  J Comput Assist Tomogr       Date:  2003 Nov-Dec       Impact factor: 1.826

4.  MRI of the brain with ultra-short echo-time pulse sequences.

Authors:  A Waldman; J H Rees; C S Brock; M D Robson; P D Gatehouse; G M Bydder
Journal:  Neuroradiology       Date:  2003-09-24       Impact factor: 2.804

5.  Rapid fat-suppressed isotropic steady-state free precession imaging using true 3D multiple-half-echo projection reconstruction.

Authors:  Aiming Lu; Ethan Brodsky; Thomas M Grist; Walter F Block
Journal:  Magn Reson Med       Date:  2005-03       Impact factor: 4.668

6.  In vivo MR thermometry of frozen tissue using R2* and signal intensity.

Authors:  Janaka P Wansapura; Bruce L Daniel; Karl K Vigen; Kim Butts
Journal:  Acad Radiol       Date:  2005-09       Impact factor: 3.173

7.  Consistent non-cartesian off-axis MRI quality: calibrating and removing multiple sources of demodulation phase errors.

Authors:  Youngkyoo Jung; Yogesh Jashnani; Richard Kijowski; Walter F Block
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

8.  Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling.

Authors:  Jürgen Rahmer; Peter Börnert; Jan Groen; Clemens Bos
Journal:  Magn Reson Med       Date:  2006-05       Impact factor: 4.668

9.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application].

Authors:  J I Jackson; C H Meyer; D G Nishimura; A Macovski
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

10.  Simple correction method for k-space trajectory deviations in MRI.

Authors:  J H Duyn; Y Yang; J A Frank; J W van der Veen
Journal:  J Magn Reson       Date:  1998-05       Impact factor: 2.229

View more
  23 in total

1.  MRI of frozen tissue demonstrates a phase shift.

Authors:  Aiming Lu; Bruce L Daniel; Elena Kaye; Kim Butts Pauly
Journal:  Magn Reson Med       Date:  2011-05-31       Impact factor: 4.668

2.  Correction of susceptibility-induced GRE phase shift for accurate PRFS thermometry proximal to cryoablation iceball.

Authors:  Antje Kickhefel; Clifford Weiss; Joerg Roland; Patrick Gross; Fritz Schick; Rares Salomir
Journal:  MAGMA       Date:  2011-09-04       Impact factor: 2.310

3.  Three-dimensional ultrashort echo time cones T (3D UTE-cones-T ) imaging.

Authors:  Ya-Jun Ma; Michael Carl; Hongda Shao; Anthony S Tadros; Eric Y Chang; Jiang Du
Journal:  NMR Biomed       Date:  2017-03-20       Impact factor: 4.044

4.  DQF-MT MRI of connective tissues: application to tendon and muscle.

Authors:  Slawomir Kusmia; Uzi Eliav; Gil Navon; Geneviève Guillot
Journal:  MAGMA       Date:  2012-09-23       Impact factor: 2.310

5.  Imaging and quantification of iron-oxide nanoparticles (IONP) using MP-RAGE and UTE based sequences.

Authors:  Wen Hong; Qun He; Shujuan Fan; Michael Carl; Hongda Shao; Jun Chen; Eric Y Chang; Jiang Du
Journal:  Magn Reson Med       Date:  2016-08-06       Impact factor: 4.668

6.  Iterative method for predistortion of MRI gradient waveforms.

Authors:  Kevin D Harkins; Mark D Does; William A Grissom
Journal:  IEEE Trans Med Imaging       Date:  2014-04-29       Impact factor: 10.048

7.  Yet more evidence that myelin protons can be directly imaged with UTE sequences on a clinical 3T scanner: Bicomponent T2* analysis of native and deuterated ovine brain specimens.

Authors:  Shu-Juan Fan; Yajun Ma; Yanchun Zhu; Adam Searleman; Nikolaus M Szeverenyi; Graeme M Bydder; Jiang Du
Journal:  Magn Reson Med       Date:  2017-12-21       Impact factor: 4.668

8.  Quantitative ultrashort echo time imaging for assessment of massive iron overload at 1.5 and 3 Tesla.

Authors:  Axel J Krafft; Ralf B Loeffler; Ruitian Song; Aaryani Tipirneni-Sajja; M Beth McCarville; Matthew D Robson; Jane S Hankins; Claudia M Hillenbrand
Journal:  Magn Reson Med       Date:  2017-01-16       Impact factor: 4.668

9.  Short T2 contrast with three-dimensional ultrashort echo time imaging.

Authors:  Jiang Du; Mark Bydder; Atsushi M Takahashi; Michael Carl; Christine B Chung; Graeme M Bydder
Journal:  Magn Reson Imaging       Date:  2011-05       Impact factor: 2.546

10.  3D R 2 * mapping of the placenta during early gestation using free-breathing multiecho stack-of-radial MRI at 3T.

Authors:  Tess Armstrong; Dapeng Liu; Thomas Martin; Rinat Masamed; Carla Janzen; Cass Wong; Teresa Chanlaw; Sherin U Devaskar; Kyunghyun Sung; Holden H Wu
Journal:  J Magn Reson Imaging       Date:  2018-08-24       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.