MRI of the brain with ultra-short echo-time pulse sequences.

A Waldman1, J H Rees, C S Brock, M D Robson, P D Gatehouse, G M Bydder.   

Abstract

As well as the long-T2 relaxation components normally detected with conventional imaging techniques, the brain has short-T2 components. We wished to use ultra-short (0.08 ms) echo time (UTE) pulse sequences to assess the feasibility of imaging these in normal subjects and patients. UTE sequences were employed, with or without fat suppression, 90 degree long-T2 suppression pulses, and selective nulling of long-T2 components using an inversion pulse. Subtraction of later echoes from the first was also used to reduce the signal from long-T2 components. We studied dive normal subjects and 15 patients with various diseases. Short-T2 components were demonstrated in grey and white matter. Increased signal from these components was seen in meningeal disease, probable calcification, presumed cavernomas, melanoma metastases and probable gliosis. Reduced signal was seen in some tumours, infarcts, mild multifocal vascular disease and vasogenic oedema. Further development and evaluation of these pulse sequences is warranted.

Entities:  

Mesh:

Year:  2003        PMID: 14508620     DOI: 10.1007/s00234-003-1076-z

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  4 in total

1.  Magnetization transfer in MRI: a review.

Authors:  R M Henkelman; G J Stanisz; S J Graham
Journal:  NMR Biomed       Date:  2001-04       Impact factor: 4.044

2.  Lung parenchyma: projection reconstruction MR imaging.

Authors:  C J Bergin; J M Pauly; A Macovski
Journal:  Radiology       Date:  1991-06       Impact factor: 11.105

3.  Magnetization transfer and T2 relaxation components in tissue.

Authors:  R Harrison; M J Bronskill; R M Henkelman
Journal:  Magn Reson Med       Date:  1995-04       Impact factor: 4.668

Review 4.  Magnetic resonance imaging of short T2 components in tissue.

Authors:  P D Gatehouse; G M Bydder
Journal:  Clin Radiol       Date:  2003-01       Impact factor: 2.350

  4 in total
  42 in total

1.  Review. The Agfa Mayneord lecture: MRI of short and ultrashort T₂ and T₂* components of tissues, fluids and materials using clinical systems.

Authors:  G M Bydder
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

2.  Direct magnetic resonance detection of myelin and prospects for quantitative imaging of myelin density.

Authors:  Michael J Wilhelm; Henry H Ong; Suzanne L Wehrli; Cheng Li; Ping-Huei Tsai; David B Hackney; Felix W Wehrli
Journal:  Proc Natl Acad Sci U S A       Date:  2012-05-24       Impact factor: 11.205

3.  Ultrashort echo time imaging of normal middle ear ossicles: a feasibility study.

Authors:  K Yamashita; T Yoshiura; A Hiwatashi; H Kamano; H Honda
Journal:  Dentomaxillofac Radiol       Date:  2012-06-29       Impact factor: 2.419

4.  Designing long-T2 suppression pulses for ultrashort echo time imaging.

Authors:  Peder E Z Larson; Paul T Gurney; Krishna Nayak; Garry E Gold; John M Pauly; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2006-07       Impact factor: 4.668

5.  Selective 3D ultrashort TE imaging: comparison of "dual-echo" acquisition and magnetization preparation for improving short-T 2 contrast.

Authors:  Jürgen Rahmer; Ulrike Blume; Peter Börnert
Journal:  MAGMA       Date:  2007-03-13       Impact factor: 2.310

6.  Using adiabatic inversion pulses for long-T2 suppression in ultrashort echo time (UTE) imaging.

Authors:  Peder E Z Larson; Steven M Conolly; John M Pauly; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2007-11       Impact factor: 4.668

Review 7.  Magnetic resonance imaging of myelin.

Authors:  Cornelia Laule; Irene M Vavasour; Shannon H Kolind; David K B Li; Tony L Traboulsee; G R Wayne Moore; Alex L MacKay
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

Review 8.  Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques.

Authors:  Matthias Hofmann; Bernd Pichler; Bernhard Schölkopf; Thomas Beyer
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

9.  Improved half RF slice selectivity in the presence of eddy currents with out-of-slice saturation.

Authors:  Sonal Josan; Elena Kaye; John M Pauly; Bruce L Daniel; Kim Butts Pauly
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

10.  Ramped hybrid encoding for improved ultrashort echo time imaging.

Authors:  Hyungseok Jang; Curtis N Wiens; Alan B McMillan
Journal:  Magn Reson Med       Date:  2015-09-18       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.