Multiple autoclave cycles affect the surface of rotary nickel-titanium files: an atomic force microscopy study.

Caroline R A Valois1, Luciano P Silva, Ricardo B Azevedo.   

Abstract

The purpose of this study was to evaluate the surface of rotary nickel-titanium (Ni-Ti) files after multiple autoclave cycles. Two different types of rotary Ni-Ti (Greater Taper and ProFile) were attached to a glass base. After 1, 5, and 10 autoclave cycles the files were positioned in the atomic force microscope. The analyses were performed on 15 different points. The same files were used as control before any autoclave cycle. The following vertical topographic parameters were measured: arithmetic mean roughness, maximum height, and root mean square. The differences were tested by analysis of variance with Tukey test. All topographic parameters were higher for both Greater Taper and ProFile after 10 cycles compared with the control (P < .05). ProFile also showed higher topographic parameters after 5 cycles compared with the control (P < .05). The results indicated that multiple autoclave cycles increase the depth of surface irregularities located on rotary Ni-Ti files.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18570996     DOI: 10.1016/j.joen.2008.02.028

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  19 in total

1.  Effect of multiple autoclave cycles on the surface roughness of HyFlex CM and HyFlex EDM files: an atomic force microscopy study.

Authors:  K Yılmaz; G Uslu; T Özyürek
Journal:  Clin Oral Investig       Date:  2018-02-13       Impact factor: 3.573

2.  Microstructural, microchemical, and mechanical changes associated with the clinical reuse of two nickel-titanium endodontic instruments.

Authors:  Felipe Augusto Restrepo-Restrepo; Viviana Andrea Holguín-Vásquez; Syldana Julieth Cañas-Jiménez; Paula Andrea Villa-Machado; Sara Ochoa-Soto; Claudia Patricia Ossa-Orozco; Sergio Iván Tobón-Arroyave
Journal:  Dent Res J (Isfahan)       Date:  2021-06-22

3.  Evaluation of deformation and fracture rates for nickel-titanium rotary instruments according to the frequency of clinical use.

Authors:  Ayça Yılmaz; Sıtkı Selçuk Gökyay; Rüştü Dağlaroğlu; Işıl Karagöz Küçükay
Journal:  Eur Oral Res       Date:  2018-05-01

4.  Electrochemical corrosion assessment of RaCe and Mtwo rotary nickle-titanium instruments after clinical use and sterilization.

Authors:  S Shahi; H Mokhtari; S Rahimi; V Shiezadeh; H Ashasi; M Abdolrahimi; M Foroughreyhani
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-03-01

5.  Influence of microwave sterilization on the cutting capacity of carbide burs.

Authors:  Laiza Maria Grassi Fais; Lígia Antunes Pereira Pinelli; Gelson Luis Adabo; Regina Helena Barbosa Tavares da Silva; Caroline Canhizares Marcelo; Dalton Geraldo Guaglianoni
Journal:  J Appl Oral Sci       Date:  2009 Nov-Dec       Impact factor: 2.698

6.  The effect of multiple autoclave cycles on the surface of rotary nickel-titanium endodontic files: An in vitro atomic force microscopy investigation.

Authors:  Ashish Shashikant Nair; Mahima Tilakchand; Balaram Damodar Naik
Journal:  J Conserv Dent       Date:  2015 May-Jun

7.  Comparative evaluation of the effects of multiple autoclaving on cyclic fatigue resistance of three different rotary Ni-Ti instruments: An in vitro study.

Authors:  Kanthimathinathan Meenakshi Sundaram; Rajesh A V Ebenezar; Mohamed Fayas Ghani; Leena Martina; Ashwin Narayanan; Bejoy Mony
Journal:  J Conserv Dent       Date:  2013-07

8.  The effect of 5% sodium hypochlorite, 17% EDTA and triphala on two different rotary Ni-Ti instruments: An AFM and EDS analysis.

Authors:  Pramod Siva Prasad; Jonathan Emi Sam; Arvind Kumar
Journal:  J Conserv Dent       Date:  2014-09

9.  Experimental evaluation of cyclic fatigue resistance of four different nickel-titanium instruments after immersion in sodium hypochlorite and/or sterilization.

Authors:  Üreyen Kaya Bulem; Ayse Diljin Kececi; Hilmi Egemen Guldas
Journal:  J Appl Oral Sci       Date:  2013 Nov-Dec       Impact factor: 2.698

10.  Effect of Autoclave Cycles on Surface Characteristics of S-File Evaluated by Scanning Electron Microscopy.

Authors:  Hamid Razavian; Pedram Iranmanesh; Hamid Mojtahedi; Rahman Nazeri
Journal:  Iran Endod J       Date:  2015-12-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.