Literature DB >> 18568349

Atrial septal defects type II: noninvasive evaluation of patients before implantation of an Amplatzer Septal Occluder and on follow-up by magnetic resonance imaging compared with TEE and invasive measurement.

Christoph Weber1, Michael Weber, Okan Ekinci, Thomas Neumann, Anja Deetjen, Andreas Rolf, Gerhard Adam, Christian W Hamm, Thorsten Dill.   

Abstract

The purpose of this study was to evaluate morphological and functional MRI of atrial septal defects (ASD) before and after interventional occlusion by the Amplatzer Septal Occluder (AOC) in comparison to trans-oesophageal echocardiography (TEE), invasive balloon measurement (IVBM) and cardiac catheterisation (QCC). Sixty patients with an ASD type II were enrolled. They underwent TEE, IVBM, QCC and MRI at 1.5T. Cine gradient echo, steady-state free precession sequences and a gradient echo phase contrast sequence were used. In MRI, pulmonary-to-systemic flow ratio (Qp/Qs) was calculated and compared with the QCC Qp/Qs ratio. Qp/Qs ratio in baseline MRI examination was 1.56 +/- 0.29 (range: 1.05-2.2) and in QCC 1.71 +/- 0.30 (range: 1.2-2.4) with a significant correlation (R = 0.65, P < 0.01). Defect size on MRI was 15.3 +/- 7.4 mm (range: 3-30 mm), in TEE 14.3 +/- 4.9 mm (range: 4-24 mm), and the balloon stretched diameter in IVBM was 23.4 +/- 4.2 mm (range: 14-32 mm). Correlation between defect size in MRI vs. TEE was R = 0.67 (P < 0.01) and MRI vs. IVBM was R = 0.77 (P < 0.01). Right ventricular volumes decreased after intervention. MRI is an accurate noninvasive test for diagnosis, planning and follow-up after interventional ASD occlusion using an AOC.

Entities:  

Mesh:

Year:  2008        PMID: 18568349     DOI: 10.1007/s00330-008-1033-7

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  24 in total

1.  Balloon sizing and transcatheter closure of acute atrial septal defects guided by magnetic resonance fluoroscopy: assessment and validation in a large animal model.

Authors:  Simon Schalla; Maythem Saeed; Charles B Higgins; Oliver Weber; Alastair Martin; Phillip Moore
Journal:  J Magn Reson Imaging       Date:  2005-03       Impact factor: 4.813

2.  Cryptogenic stroke patients with patent foramen ovale should be closed only in the setting of a randomized control trial.

Authors:  Robert A Felberg
Journal:  Catheter Cardiovasc Interv       Date:  2007-01       Impact factor: 2.692

3.  Real-time-MR guidance for placement of a self-made fully MR-compatible atrial septal occluder: in vitro test.

Authors:  A Buecker; E Spuentrup; R Grabitz; F Freudenthal; T Schaeffter; J J van Vaals; W Günther
Journal:  Rofo       Date:  2002-03

4.  The value of transesophageal echocardiography in transcatheter closure of atrial septal defects in the oval fossa using the Amplatzer septal occluder.

Authors:  H A Latiff; H Samion; G Kandhavel; B A Aziz; M Alwi
Journal:  Cardiol Young       Date:  2001-03       Impact factor: 1.093

5.  The role of transesophageal echocardiography in transcatheter closure of secundum atrial septal defects by the Amplatzer septal occluder.

Authors:  U Mazic; P Gavora; J Masura
Journal:  Am Heart J       Date:  2001-09       Impact factor: 4.749

6.  [The role of MRI for the evaluation of atrial septal defects before and after percutaneous occlusion with the amplatzer septal occluder(R)].

Authors:  C Weber; T Dill; I Mommert; T Hofmann; G Adam
Journal:  Rofo       Date:  2002-11

7.  Measurement of atrial septal defect size: a comparative study between three-dimensional transesophageal echocardiography and the standard balloon sizing methods.

Authors:  W Zhu; Q L Cao; J Rhodes; Z M Hijazi
Journal:  Pediatr Cardiol       Date:  2000 Sep-Oct       Impact factor: 1.655

8.  Long-term outcome of transcatheter secundum-type atrial septal defect closure using Amplatzer septal occluders.

Authors:  Jozef Masura; Pavol Gavora; Tomaz Podnar
Journal:  J Am Coll Cardiol       Date:  2005-02-15       Impact factor: 24.094

9.  Noninvasive evaluation of the ratio of pulmonary to systemic flow in atrial septal defect by duplex Doppler echocardiography.

Authors:  A Kitabatake; M Inoue; M Asao; H Ito; T Masuyama; J Tanouchi; T Morita; M Hori; H Yoshima; K Ohnishi
Journal:  Circulation       Date:  1984-01       Impact factor: 29.690

10.  Dynamic three-dimensional echocardiographic assessment of intracardiac blood flow jets.

Authors:  A Delabays; L Sugeng; N G Pandian; T L Hsu; S J Ho; C H Chen; G Marx; S L Schwartz; Q L Cao
Journal:  Am J Cardiol       Date:  1995-11-15       Impact factor: 2.778

View more
  5 in total

1.  How to Size ASDs for Percutaneous Closure.

Authors:  Isabelle Boon; Katrien Vertongen; Bernard P Paelinck; Laurent Demulier; An Van Berendoncks; Catherine De Maeyer; Fabienne Marchau; Joseph Panzer; Kristof Vandekerckhove; Daniel De Wolf
Journal:  Pediatr Cardiol       Date:  2017-09-27       Impact factor: 1.655

2.  Assessment of atrial septal defects in adults comparing cardiovascular magnetic resonance with transoesophageal echocardiography.

Authors:  Karen S L Teo; Patrick J Disney; Benjamin K Dundon; Matthew I Worthley; Michael A Brown; Prashanthan Sanders; Stephen G Worthley
Journal:  J Cardiovasc Magn Reson       Date:  2010-07-22       Impact factor: 5.364

Review 3.  2014 Korean guidelines for appropriate utilization of cardiovascular magnetic resonance imaging: a joint report of the Korean Society of Cardiology and the Korean Society of Radiology.

Authors:  Yeonyee E Yoon; Yoo Jin Hong; Hyung-Kwan Kim; Jeong A Kim; Jin Oh Na; Dong Hyun Yang; Young Jin Kim; Eui-Young Choi
Journal:  Korean J Radiol       Date:  2014-11-07       Impact factor: 3.500

Review 4.  2014 korean guidelines for appropriate utilization of cardiovascular magnetic resonance imaging: a joint report of the korean society of cardiology and the korean society of radiology.

Authors:  Yeonyee E Yoon; Yoo Jin Hong; Hyung-Kwan Kim; Jeong A Kim; Jin Oh Na; Dong Hyun Yang; Young Jin Kim; Eui-Young Choi
Journal:  Korean Circ J       Date:  2014-11-25       Impact factor: 3.243

5.  Phase contrast cardiac magnetic resonance imaging versus transoesophageal echocardiography for the evaluation of feasibility for transcatheter closure of atrial septal defects.

Authors:  Tariq Rashid Shah; Jahangir Rashid Beig; Naseer Ahmad Choh; Fayaz Ahmad Rather; Irfan Yaqoob; Vicar Mohammad Jan
Journal:  Egypt Heart J       Date:  2022-04-13
  5 in total