Literature DB >> 18562725

Evaluation of coronary stent patency and in-stent restenosis with dual-source CT coronary angiography without heart rate control.

Dilek Oncel1, Guray Oncel, Ahmet Tastan, Batuhan Tamci.   

Abstract

OBJECTIVE: Dual-source CT has excellent temporal resolution and allows good visualization of coronary vessels without heart rate control. Our aim was to evaluate the diagnostic performance of dual-source CT in the evaluation of coronary stent patency to determine whether the good temporal resolution would improve visualization of stents. SUBJECTS AND METHODS: Thirty-five consecutively registered patients (10 women, 25 men; mean age, 65 years) with 48 stents were examined prospectively without heart rate controlling agents. Observers evaluating image quality and patency of the stents were blinded to the results of invasive coronary angiography. In-stent restenosis was defined as more than 50% narrowing of the lumen.
RESULTS: All stents were considered assessable for diagnosis with dual-source CT. In 85% (41/48) of the stents, image quality was good. Only two patent stents were misidentified as being stenotic. All other stents with stenosis and occlusion were correctly diagnosed. The sensitivity, specificity, positive and negative predictive values, and accuracy of dual-source CT in the detection of in-stent restenosis and occlusion were 100%, 94%, 89%, 100%, and 96%, respectively. The McNemar test result showed no statistically significant difference between the diagnostic performance of dual-source CT and that of invasive coronary angiography. The kappa indexes showed excellent intraobserver and interobserver agreement.
CONCLUSION: The high temporal resolution of dual-source CT is helpful for evaluation of coronary stents without heart rate control. Further confirmation of our preliminary results may broaden the clinical indications for CT angiography as a diagnostic test for the exclusion of in-stent restenosis.

Entities:  

Mesh:

Year:  2008        PMID: 18562725     DOI: 10.2214/AJR.07.3560

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  12 in total

1.  Prevalence and prognosis of coronary stent gap detected by multi-detector CT: a follow-up study.

Authors:  Xinghua Zhang; Li Yang; Haiyue Ju; Fan Zhang; Jian Wu; Bin He; Yundai Chen
Journal:  Eur Radiol       Date:  2012-04-27       Impact factor: 5.315

2.  Banding and Step-Stair Artifacts on the Cardiac-CT Caused By Pseudo-Ectopic Beats.

Authors:  Amolak Singh; Yash Sethi; Sonya Watkins; Angela Youtsey; Angie Thomas
Journal:  J Radiol Case Rep       Date:  2009-06-01

3.  Impact of an advanced image-based monoenergetic reconstruction algorithm on coronary stent visualization using third generation dual-source dual-energy CT: a phantom study.

Authors:  Stefanie Mangold; Paola M Cannaó; U Joseph Schoepf; Julian L Wichmann; Christian Canstein; Stephen R Fuller; Giuseppe Muscogiuri; Akos Varga-Szemes; Konstantin Nikolaou; Carlo N De Cecco
Journal:  Eur Radiol       Date:  2015-09-15       Impact factor: 5.315

4.  Coronary in-stent restenosis: predisposing clinical and stent-related factors, diagnostic performance and analyses of inaccuracies in 320-row computed tomography angiography.

Authors:  Yung-Liang Wan; Pei-Kwei Tsay; Chun-Chi Chen; Yu-Hsiang Juan; Yu-Chieh Huang; Wen-Hui Chan; Ming-Shien Wen; I-Chang Hsieh
Journal:  Int J Cardiovasc Imaging       Date:  2016-04-22       Impact factor: 2.357

5.  CT vs SPECT: CT is the first-line test for the diagnosis and prognosis of stable coronary artery disease.

Authors:  Ahmed Aljizeeri; Myra S Cocker; Benjamin J W Chow
Journal:  J Nucl Cardiol       Date:  2013-06       Impact factor: 5.952

6.  Combination of a low-tube-voltage technique with hybrid iterative reconstruction (iDose) algorithm at coronary computed tomographic angiography.

Authors:  Yoshinori Funama; Katsuyuki Taguchi; Daisuke Utsunomiya; Seitaro Oda; Yumi Yanaga; Yasuyuki Yamashita; Kazuo Awai
Journal:  J Comput Assist Tomogr       Date:  2011 Jul-Aug       Impact factor: 1.826

7.  Coronary artery stent imaging with 128-slice dual-source CT using high-pitch spiral acquisition in a cardiac phantom: comparison with the sequential and low-pitch spiral mode.

Authors:  Florian Wolf; Sebastian Leschka; Christian Loewe; Peter Homolka; Christina Plank; Ruediger Schernthaner; Dominik Bercaczy; Robert Goetti; Johannes Lammer; Guy Friedrich; Borut Marincek; Hatem Alkadhi; Gudrun Feuchtner
Journal:  Eur Radiol       Date:  2010-04-16       Impact factor: 5.315

Review 8.  Coronary CT angiography: current status and continuing challenges.

Authors:  Z Sun; G H Choo; K H Ng
Journal:  Br J Radiol       Date:  2012-01-17       Impact factor: 3.039

9.  Improved Estimation of Coronary Plaque and Luminal Attenuation Using a Vendor-specific Model-based Iterative Reconstruction Algorithm in Contrast-enhanced CT Coronary Angiography.

Authors:  Yoshinori Funama; Daisuke Utsunomiya; Kenichiro Hirata; Katsuyuki Taguchi; Takeshi Nakaura; Seitaro Oda; Masafumi Kidoh; Hideaki Yuki; Yasuyuki Yamashita
Journal:  Acad Radiol       Date:  2017-04-07       Impact factor: 3.173

10.  Modelling the effect of a functional endothelium on the development of in-stent restenosis.

Authors:  Hannan Tahir; Carles Bona-Casas; Alfons G Hoekstra
Journal:  PLoS One       Date:  2013-06-13       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.