Literature DB >> 22470663

Banding and Step-Stair Artifacts on the Cardiac-CT Caused By Pseudo-Ectopic Beats.

Amolak Singh1, Yash Sethi, Sonya Watkins, Angela Youtsey, Angie Thomas.   

Abstract

Step-stair and banding artifacts may result from irregular ventricular rhythm caused by atrial fibrillation or premature ectopic ventricular contractions. In the case reported here, severe banding and misalignment artifacts occurred due to electrocardiographic noise mimicking ectopic beats. Severe EKG noise or pseudo-ectopic beats may cause rare but serious artifacts during cardiac-CT acquisition. Vendor-provided software for correcting ectopic beats can be used to remove pseudo-ectopic beats and eliminate artifacts caused by the EKG noise. All efforts should be made to prevent this kind of problem from happening in the first place.

Entities:  

Keywords:  Cardiac-ct; banding artifacts; coronary artery disease

Year:  2009        PMID: 22470663      PMCID: PMC3303318          DOI: 10.3941/jrcr.v3i6.219

Source DB:  PubMed          Journal:  J Radiol Case Rep        ISSN: 1943-0922


  7 in total

1.  Radiation dose, image quality, stenosis measurement, and CT densitometry using ECG-triggered coronary 64-MDCT angiography: a phantom study.

Authors:  Jun Horiguchi; Masao Kiguchi; Chikako Fujioka; Yun Shen; Ryuichi Arie; Kenichi Sunasaka; Katsuhide Ito
Journal:  AJR Am J Roentgenol       Date:  2008-02       Impact factor: 3.959

Review 2.  Artifacts in ECG-synchronized MDCT coronary angiography.

Authors:  L J M Kroft; A de Roos; J Geleijns
Journal:  AJR Am J Roentgenol       Date:  2007-09       Impact factor: 3.959

3.  Evaluation of coronary stents and stenoses at different heart rates with dual source spiral CT (DSCT).

Authors:  Michael M Lell; Christoph Panknin; Roya Saleh; James W Sayre; Bernhard Schmidt; Howard Dinh; Stefan G Ruehm
Journal:  Invest Radiol       Date:  2007-07       Impact factor: 6.016

4.  Artifacts in CT: recognition and avoidance.

Authors:  Julia F Barrett; Nicholas Keat
Journal:  Radiographics       Date:  2004 Nov-Dec       Impact factor: 5.333

5.  Evaluation of coronary stent patency and in-stent restenosis with dual-source CT coronary angiography without heart rate control.

Authors:  Dilek Oncel; Guray Oncel; Ahmet Tastan; Batuhan Tamci
Journal:  AJR Am J Roentgenol       Date:  2008-07       Impact factor: 3.959

6.  Effectiveness of dual-source CT coronary angiography for the evaluation of coronary artery disease in patients with atrial fibrillation: initial experience.

Authors:  Dilek Oncel; Guray Oncel; Ahmet Tastan
Journal:  Radiology       Date:  2007-12       Impact factor: 11.105

7.  Initial evaluation of coronary images from 320-detector row computed tomography.

Authors:  Frank J Rybicki; Hansel J Otero; Michael L Steigner; Gabriel Vorobiof; Leelakrishna Nallamshetty; Dimitrios Mitsouras; Hale Ersoy; Richard T Mather; Philip F Judy; Tianxi Cai; Karl Coyner; Kurt Schultz; Amanda G Whitmore; Marcelo F Di Carli
Journal:  Int J Cardiovasc Imaging       Date:  2008-03-27       Impact factor: 2.357

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.