Literature DB >> 18557743

Comparison of cardiac output measurement using the CardioQP oesophageal Doppler with cardiac output measurement using thermodilution technique in children during heart catheterisation.

W Knirsch, O Kretschmar, M Tomaske, K Stutz, N Nagdyman, C Balmer, A Schmitz, F Berger, U Bauersfeld, M Weiss.   

Abstract

The minimally invasive CardioQP oesophageal Doppler probe estimates cardiac output by measuring blood flow velocity in the descending aorta. Individual variables to enter are patient's age, weight and height. We measured cardiac output simultaneously with CardioQP and pulmonary artery catheter thermodilution techniques during heart catheterisation in 40 paediatric patients with congenital heart defects. Median [range] age was 8.2 years [0.5-16.7 years], cardiac output values measured by thermodilution and CardioQP were 3.6 l.min(-1) [1.2-7.1 l.min(-1)] and 3.0 l.min(-1) [0.7-6.7 l.min(-1)], respectively. These values showed only moderate correlation (r = 0.809; p < 0.0001). Bias and precision were 0.66 l.min(-1) and 1.79 l.min(-1) (95% limits of agreement: -1.13 to +2.45 l.min(-1)). Based on our preliminary experience, cardiac output values measured by CardioQP in children do not reliably represent cardiac output values compared with the thermodilution technique. We suggest measurement of individual aortic diameter to improve performance of the CardioQP.

Entities:  

Mesh:

Year:  2008        PMID: 18557743     DOI: 10.1111/j.1365-2044.2008.05495.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  8 in total

Review 1.  Accuracy and precision of minimally-invasive cardiac output monitoring in children: a systematic review and meta-analysis.

Authors:  Koichi Suehiro; Alexandre Joosten; Linda Suk-Ling Murphy; Olivier Desebbe; Brenton Alexander; Sang-Hyun Kim; Maxime Cannesson
Journal:  J Clin Monit Comput       Date:  2015-08-29       Impact factor: 2.502

Review 2.  Transesophageal Doppler devices: A technical review.

Authors:  Patrick Schober; Stephan A Loer; Lothar A Schwarte
Journal:  J Clin Monit Comput       Date:  2009-10-20       Impact factor: 2.502

3.  Can the descending aortic stroke volume be estimated by transesophageal descending aortic photoplethysmography?

Authors:  Peng Ling; Gong Quan; Yu Siyuan; Gao Bo; Wei Wei
Journal:  J Anesth       Date:  2017-03-27       Impact factor: 2.078

4.  Capability of a new paediatric oesophageal Doppler monitor to detect changes in cardiac output during testing of external pacemakers after cardiac surgery.

Authors:  Thilo Fleck; Stephan Schubert; Brigitte Stiller; Matthias Redlin; Peter Ewert; Nicole Nagdyman; Felix Berger
Journal:  J Clin Monit Comput       Date:  2011-11-12       Impact factor: 2.502

Review 5.  Fluid responsiveness in the pediatric population.

Authors:  Ji-Hyun Lee; Eun-Hee Kim; Young-Eun Jang; Hee-Soo Kim; Jin-Tae Kim
Journal:  Korean J Anesthesiol       Date:  2019-10-01

6.  Neonatal Impedance Cardiography in Asphyxiated Piglets-A Feasibility Study.

Authors:  Gazmend Berisha; Rønnaug Solberg; Claus Klingenberg; Anne Lee Solevåg
Journal:  Front Pediatr       Date:  2022-02-25       Impact factor: 3.418

Review 7.  Hemodynamic monitoring and management of pediatric septic shock.

Authors:  En-Pei Lee; Han-Ping Wu; Oi-Wa Chan; Jainn-Jim Lin; Shao-Hsuan Hsia
Journal:  Biomed J       Date:  2021-10-12       Impact factor: 7.892

8.  Physiological effects of invasive ventilation with neurally adjusted ventilatory assist (NAVA) in a crossover study.

Authors:  Jean-Michel Liet; François Barrière; Bénédicte Gaillard-Le Roux; Pierre Bourgoin; Arnaud Legrand; Nicolas Joram
Journal:  BMC Pediatr       Date:  2016-11-08       Impact factor: 2.125