Literature DB >> 10475551

Primary total hip arthroplasty with a cementless porous-coated anatomic total hip prosthesis: 10- to 12-year results of prospective and consecutive series.

Y H Kim1, J S Kim, S H Cho.   

Abstract

We performed a prospective study in 108 consecutive patients (116 hips) who were followed for a minimum of 10 years (10-12 years) after primary total hip arthroplasty using an uncemented porous-coated anatomic (PCA) hip prosthesis. The average age of the patients at operation was 48.4 years (range, 19-85 years), and the diagnosis was avascular necrosis of the femoral head in 46 hips, neglected femoral neck fracture in 27, osteoarthrosis secondary to childhood pyogenic arthritis in 24, childhood tuberculous arthritis in 5, and miscellaneous in 14. The average preoperative Harris Hip Score was 55 points, which improved to 87 points at 11 years. Seventy-five hips (65%) were excellent, 11 (9%) were good, and 30 (39%) were poor. The overall rate of revision was 15% (17 of 116 hips). The rate of revision of the femoral component was 11% (13 of 116 hips), and the rate of revision of the acetabular component was 15% (17 of 116 hips). The prevalence of thigh pain was 28% at 11 years. The increase in the incidence of aseptic loosening of the femoral component was found to explain the high incidence of severe thigh pain at 11 years' follow-up. At 11 years, there was femoral osteolysis in 69 hips (59%) and acetabular osteolysis in 65 hips (56%). At 6 years, 20 hips (17%) showed definite wear of the polyethylene liner. At 11 years, 81 hips (70%) showed definite wear of the polyethylene liner. Because the complication rate of the PCA hip prosthesis with respect to loosening, osteolysis, and excessive wear in the polyethylene liner is high, we abandoned the use of this implant.

Entities:  

Mesh:

Year:  1999        PMID: 10475551     DOI: 10.1016/s0883-5403(99)90074-8

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  19 in total

1.  Long-term results of the standard Wagner cup.

Authors:  Uwe Demmelmeyer; Annemarie Schraml; Wolfgang Hönle; Alexander Schuh
Journal:  Int Orthop       Date:  2009-04-08       Impact factor: 3.075

2.  Survivorship of 2000 tapered titanium porous plasma-sprayed femoral components.

Authors:  Adolph V Lombardi; Keith R Berend; Thomas H Mallory; Michael D Skeels; Joanne B Adams
Journal:  Clin Orthop Relat Res       Date:  2008-10-31       Impact factor: 4.176

3.  Partial weightbearing is not necessary after cementless total hip arthroplasty: a two-year prospective randomized study on 100 patients.

Authors:  Max Markmiller; Thomas Weiss; Peter Kreuz; Axel Rüter; Gerhard Konrad
Journal:  Int Orthop       Date:  2010-07-11       Impact factor: 3.075

Review 4.  Osteonecrosis is not a predictor of poor outcomes in primary total hip arthroplasty: a systematic literature review.

Authors:  Henning R Johannson; Michael G Zywiel; David R Marker; Lynne C Jones; Mike S McGrath; Michael A Mont
Journal:  Int Orthop       Date:  2010-02-25       Impact factor: 3.075

5.  THA with highly cross-linked polyethylene in patients 50 years or younger.

Authors:  Derek S Shia; John C Clohisy; Mark F Schinsky; John M Martell; William J Maloney
Journal:  Clin Orthop Relat Res       Date:  2009-01-14       Impact factor: 4.176

6.  Long-term results of cementless anatomic total hip replacement in dysplastic hips.

Authors:  Matteo Bruzzone; Massimo La Russa; Giacomo Garzaro; Andrea Ferro; Paolo Rossi; Filippo Castoldi; Roberto Rossi
Journal:  Chir Organi Mov       Date:  2009-10-30

7.  Outcomes after THA in patients with high hip dislocation after childhood sepsis.

Authors:  Young-Hoo Kim; Hee-Soo Seo; Jun-Shik Kim
Journal:  Clin Orthop Relat Res       Date:  2008-12-06       Impact factor: 4.176

Review 8.  Hip resurfacing versus total hip arthroplasty: a systematic review comparing standardized outcomes.

Authors:  Deborah A Marshall; Karen Pykerman; Jason Werle; Diane Lorenzetti; Tracy Wasylak; Tom Noseworthy; Donald A Dick; Greg O'Connor; Aish Sundaram; Sanne Heintzbergen; Cy Frank
Journal:  Clin Orthop Relat Res       Date:  2014-04-04       Impact factor: 4.176

9.  The Bimetric cementless total hip replacement: 7-18 year follow-up assessing the influence of acetabular design on survivorship.

Authors:  R C Russell; A Ghassemi; J H Dorrell; D P Powles
Journal:  Int Orthop       Date:  2008-06-13       Impact factor: 3.075

10.  THA using an anatomic stem in patients with femoral head osteonecrosis.

Authors:  Yong-Chan Ha; Hee Joong Kim; Shin-Yoon Kim; Tae-Young Kim; Kyung-Hoi Koo
Journal:  Clin Orthop Relat Res       Date:  2008-03-08       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.