Magnetic retention and bar-clip attachment for implant-retained auricular prostheses: a comparative analysis.

Andréa Alves de Sousa1, Beatriz Silva Câmara Mattos.   

Abstract

Retention systems for implant-retained auricular prostheses using either bar-clip attachments with 2 or 3 clips or retention with 2 or 3 magnets were wear tested (insertion and removal cycles) to simulate clinical periods of use. Measurements were taken at intervals of 540 cycles, which represents a period of use of approximately 6 months, for up to 3,240 cycles. Assessments of retentive force were carried out before, during, and after the wear test. Statistical analysis indicated that the bar-clip systems provided higher retention than the magnetic systems. The bar-clip attachment with 2 clips showed a significant loss of retentive force after wear testing (P < .05), suggesting lower durability and shorter clinical life. The retention provided by the bar-clip attachment with 3 clips remained stronger than that provided by all other systems tested. At the end of the wear test, the magnetic systems showed very little loss of retention but were still less retentive than the bar-clip systems, suggesting higher durability under clinical simulation despite the lower retention initially provided.

Mesh:

Year:  2008        PMID: 18548962

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  8 in total

1.  Implant retained auricular prosthesis with a modified hader bar: a case report.

Authors:  M Lovely; Pradeep C Dathan; Dinesh Gopal; Biji Thomas George; K Chandrasekharan Nair
Journal:  J Indian Prosthodont Soc       Date:  2013-03-21

Review 2.  Prosthetics in Facial Reconstruction.

Authors:  Jaclyn Klimczak; Samuel Helman; Sameep Kadakia; Raja Sawhney; Manoj Abraham; Allison K Vest; Yadranko Ducic
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2017-05-22

Review 3.  Osseointegrated Implants and Prosthetic Reconstruction Following Skull Base Surgery.

Authors:  Shirley Hu; Demetri Arnaoutakis; Sameep Kadakia; Allison Vest; Raja Sawhney; Yadranko Ducic
Journal:  Semin Plast Surg       Date:  2017-10-25       Impact factor: 2.314

4.  Influence of opacifiers on dimensional stability and detail reproduction of maxillofacial silicone elastomer.

Authors:  Marcelo C Goiato; Marcela F Haddad; Mário A C Sinhoreti; Daniela M dos Santos; Aldiéris A Pesqueira; Amália Moreno
Journal:  Biomed Eng Online       Date:  2010-12-16       Impact factor: 2.819

5.  A different wax sculpture technique for implant-retained auricular prosthesis.

Authors:  Necla Demir; Pınar Cevik; Yener Okutan; A Nilgun Ozturk; Bahar Colpan
Journal:  Eur J Dent       Date:  2015 Jul-Sep

6.  Stability of the prosthetic screws of three types of craniofacial prostheses retention systems.

Authors:  Antonio Gabriel Lanata-Flores; Eder Alberto Sigua-Rodriguez; Douglas Rangel Goulart; Veber Luiz Bomfim-Azevedo; Sergio Olate; José Ricardo de Albergaria-Barbosa
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2016-12-27

7.  The effect of different storage conditions on the physical properties of pigmented medical grade I silicone maxillofacial material.

Authors:  Ayman A Al-Dharrab; Seham B Tayel; Mona H Abodaya
Journal:  ISRN Dent       Date:  2013-03-28

8.  A simplified technique for orientation of a bone anchored auricular prostheses: a clinical report.

Authors:  Hussein G El Charkawi; Ahmed G El Sharkawy
Journal:  J Oral Maxillofac Res       Date:  2012-10-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.