Literature DB >> 18542895

[Allergy diagnostics in suspected implant intolerance: practical approach. A position paper of the German Contact Dermatitis Research Group (DKG)].

J Geier1, H Lessmann, D Becker, P Thomas.   

Abstract

Entities:  

Mesh:

Year:  2008        PMID: 18542895     DOI: 10.1007/s00105-008-1587-y

Source DB:  PubMed          Journal:  Hautarzt        ISSN: 0017-8470            Impact factor:   0.751


× No keyword cloud information.
  13 in total

1.  The positivity ratio--another parameter to assess the diagnostic quality of a patch test preparation.

Authors:  Johannes Geier; Wolfgang Uter; Holger Lessmann; Axel Schnuch
Journal:  Contact Dermatitis       Date:  2003-05       Impact factor: 6.600

2.  Allergic contact stomatitis due to manganese in a dental prosthesis.

Authors:  José Pardo; Mercedes Rodríguez-Serna; Jesús De La Cuadra; José Miguel Fortea
Journal:  Contact Dermatitis       Date:  2004-01       Impact factor: 6.600

3.  Allergy to metals as a cause of orthopedic implant failure.

Authors:  Beata Krecisz; Marta Kieć-Swierczyńska; Katarzyna Bakowicz-Mitura
Journal:  Int J Occup Med Environ Health       Date:  2006       Impact factor: 1.843

4.  [In vitro testing for allergic contact dermatitis].

Authors:  R Brehler; H Merk
Journal:  Hautarzt       Date:  2005-12       Impact factor: 0.751

Review 5.  Hypersensitivity to titanium osteosynthesis with impaired fracture healing, eczema, and T-cell hyperresponsiveness in vitro: case report and review of the literature.

Authors:  Peter Thomas; Wolf-Dieter Bandl; Sonja Maier; Burkhard Summer; Bernhard Przybilla
Journal:  Contact Dermatitis       Date:  2006-10       Impact factor: 6.600

6.  Penetration of titanium dioxide microparticles in a sunscreen formulation into the horny layer and the follicular orifice.

Authors:  J Lademann; H Weigmann; C Rickmeyer; H Barthelmes; H Schaefer; G Mueller; W Sterry
Journal:  Skin Pharmacol Appl Skin Physiol       Date:  1999 Sep-Oct

7.  Solid phase extraction and HPLC analysis of toxic components eluted from methyl methacrylate dental materials.

Authors:  H Shintani; T Tsuchiya; Y Hata; A Nakamura
Journal:  J Anal Toxicol       Date:  1993 Mar-Apr       Impact factor: 3.367

Review 8.  Copper hypersensitivity: dermatologic aspects--an overview.

Authors:  Jurij J Hostynek; Howard I Maibach
Journal:  Rev Environ Health       Date:  2003 Jul-Sep       Impact factor: 3.458

9.  Contact dermatitis and contact sensitization among enamellers and decorators in the ceramics industry.

Authors:  A Motolese; M Truzzi; A Giannini; S Seidenari
Journal:  Contact Dermatitis       Date:  1993-02       Impact factor: 6.600

10.  [Orthopedic surgical implants and allergies. Joint statement by the Implant Allergy Working Group (AK 20) of the DGOOC (German Association of Orthopedics and Orthopedic Surgery), DKG (German Contact Dermatitis Research Group) and DGAKI (German Society for Allergology and Clinical Immunology)].

Authors:  P Thomas; A Schuh; J Ring; M Thomsen
Journal:  Hautarzt       Date:  2008-03       Impact factor: 1.198

View more
  8 in total

1.  A case series of cementless revision total knee arthroplasty in patients with benzoyl peroxide allergy.

Authors:  Frank S Fröschen; Nadine Gravius; Jan-Frederic Lau; Thomas Martin Randau; Eva Kaup; Max J Friedrich; Sascha Gravius
Journal:  Int Orthop       Date:  2018-12-11       Impact factor: 3.075

Review 2.  [Metal implant allergy update].

Authors:  P Thomas
Journal:  Hautarzt       Date:  2016-05       Impact factor: 0.751

3.  [Association between allergy to benzoyl peroxide, vitiligo and implantation of a cemented total knee joint prosthesis: Is there a connection?].

Authors:  M Gothner; L Ozokyay; P Godau; T Kälicke; G Muhr; T A Schildhauer; M Dudda
Journal:  Orthopade       Date:  2011-09       Impact factor: 1.087

Review 4.  [Hypersensitivity reactions to implantable cardiac pacemakers and defibrillators].

Authors:  B Kreft
Journal:  Hautarzt       Date:  2016-05       Impact factor: 0.751

Review 5.  [Should metal alloy discs be used for patch testing in suspected metal implant intolerance reaction?].

Authors:  P Thomas; J Geier; H Dickel; T Diepgen; U Hillen; B Kreft; A Schnuch; C Szliska; V Mahler
Journal:  Orthopade       Date:  2015-11       Impact factor: 1.087

6.  [Implant allergies].

Authors:  P Thomas; M Thomsen
Journal:  Hautarzt       Date:  2010-03       Impact factor: 0.751

Review 7.  Clinical and diagnostic challenges of metal implant allergy using the example of orthopaedic surgical implants: Part 15 of the Series Molecular Allergology.

Authors:  Peter Thomas
Journal:  Allergo J Int       Date:  2014-09-29

Review 8.  Implant allergy.

Authors:  P Thomas; B Summer
Journal:  Allergol Select       Date:  2017-08-04
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.