Literature DB >> 18538600

EPR oximetry in three spatial dimensions using sparse spin distribution.

Subhojit Som1, Lee C Potter, Rizwan Ahmad, Deepti S Vikram, Periannan Kuppusamy.   

Abstract

A method is presented to use continuous wave electron paramagnetic resonance imaging for rapid measurement of oxygen partial pressure in three spatial dimensions. A particulate paramagnetic probe is employed to create a sparse distribution of spins in a volume of interest. Information encoding location and spectral linewidth is collected by varying the spatial orientation and strength of an applied magnetic gradient field. Data processing exploits the spatial sparseness of spins to detect voxels with nonzero spin and to estimate the spectral linewidth for those voxels. The parsimonious representation of spin locations and linewidths permits an order of magnitude reduction in data acquisition time, compared to four-dimensional tomographic reconstruction using traditional spectral-spatial imaging. The proposed oximetry method is experimentally demonstrated for a lithium octa-n-butoxy naphthalocyanine (LiNc-BuO) probe using an L-band EPR spectrometer.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18538600      PMCID: PMC2630719          DOI: 10.1016/j.jmr.2008.05.004

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  31 in total

1.  Linewidth analysis of spin labels in liquids. I. Theory and data analysis.

Authors:  B H Robinson; C Mailer; A W Reese
Journal:  J Magn Reson       Date:  1999-06       Impact factor: 2.229

2.  Mapping the spin-density and lineshape distribution of free radicals using 4D spectral-spatial EPR imaging.

Authors:  P Kuppusamy; M Chzhan; A Samouilov; P Wang; J L Zweier
Journal:  J Magn Reson B       Date:  1995-05

3.  Potential for EPR oximetry to guide treatment planning for tumors.

Authors:  J A O'Hara; F Goda; J F Dunn; H M Swartz
Journal:  Adv Exp Med Biol       Date:  1997       Impact factor: 2.622

4.  Simultaneous multi-site EPR spectroscopy in vivo.

Authors:  A I Smirnov; S W Norby; R B Clarkson; T Walczak; H M Swartz
Journal:  Magn Reson Med       Date:  1993-08       Impact factor: 4.668

5.  Oxymetry deep in tissues with low-frequency electron paramagnetic resonance.

Authors:  H J Halpern; C Yu; M Peric; E Barth; D J Grdina; B A Teicher
Journal:  Proc Natl Acad Sci U S A       Date:  1994-12-20       Impact factor: 11.205

Review 6.  Oxygen in human tumors: correlations between methods of measurement and response to therapy. Summary of a workshop held November 19-20, 1992, at the National Cancer Institute, Bethesda, Maryland.

Authors:  H B Stone; J M Brown; T L Phillips; R M Sutherland
Journal:  Radiat Res       Date:  1993-12       Impact factor: 2.841

Review 7.  Developing in vivo EPR oximetry for clinical use.

Authors:  H M Swartz; T Walczak
Journal:  Adv Exp Med Biol       Date:  1998       Impact factor: 2.622

8.  Development of a highly sensitive probe for measuring oxygen in biological tissues.

Authors:  J L Zweier; M Chzhan; U Ewert; G Schneider; P Kuppusamy
Journal:  J Magn Reson B       Date:  1994-09

9.  Preparation and EPR studies of lithium phthalocyanine radical as an oxymetric probe.

Authors:  M Afeworki; N R Miller; N Devasahayam; J Cook; J B Mitchell; S Subramanian; M C Krishna
Journal:  Free Radic Biol Med       Date:  1998-07-01       Impact factor: 7.376

10.  Three-dimensional spatial EPR imaging of the rat heart.

Authors:  P Kuppusamy; P Wang; J L Zweier
Journal:  Magn Reson Med       Date:  1995-07       Impact factor: 4.668

View more
  10 in total

1.  Digital detection and processing of multiple quadrature harmonics for EPR spectroscopy.

Authors:  R Ahmad; S Som; E Kesselring; P Kuppusamy; J L Zweier; L C Potter
Journal:  J Magn Reson       Date:  2010-09-29       Impact factor: 2.229

2.  Compressed sensing of spatial electron paramagnetic resonance imaging.

Authors:  David H Johnson; Rizwan Ahmad; Guanglong He; Alexandre Samouilov; Jay L Zweier
Journal:  Magn Reson Med       Date:  2013-10-07       Impact factor: 4.668

3.  Comparison of parabolic filtration methods for 3D filtered back projection in pulsed EPR imaging.

Authors:  Zhiwei Qiao; Gage Redler; Boris Epel; Howard J Halpern
Journal:  J Magn Reson       Date:  2014-08-29       Impact factor: 2.229

Review 4.  Theory, instrumentation, and applications of electron paramagnetic resonance oximetry.

Authors:  Rizwan Ahmad; Periannan Kuppusamy
Journal:  Chem Rev       Date:  2010-05-12       Impact factor: 60.622

5.  Dual-scan acquisition for accelerated continuous-wave EPR oximetry.

Authors:  J Palmer; L C Potter; D H Johnson; J L Zweier; R Ahmad
Journal:  J Magn Reson       Date:  2012-06-13       Impact factor: 2.229

6.  Implantable resonators--a technique for repeated measurement of oxygen at multiple deep sites with in vivo EPR.

Authors:  Hongbin Li; Huagang Hou; Artur Sucheta; Benjamin B Williams; Jean P Lariviere; Md Nadeem Khan; Piotr N Lesniewski; Bernard Gallez; Harold M Swartz
Journal:  Adv Exp Med Biol       Date:  2010       Impact factor: 2.622

7.  Multisite EPR oximetry from multiple quadrature harmonics.

Authors:  R Ahmad; S Som; D H Johnson; J L Zweier; P Kuppusamy; L C Potter
Journal:  J Magn Reson       Date:  2011-11-15       Impact factor: 2.229

8.  In vivo multisite oximetry using EPR-NMR coimaging.

Authors:  R Ahmad; G Caia; L C Potter; S Petryakov; P Kuppusamy; J L Zweier
Journal:  J Magn Reson       Date:  2010-08-24       Impact factor: 2.229

Review 9.  Clinical EPR: unique opportunities and some challenges.

Authors:  Harold M Swartz; Benjamin B Williams; Bassem I Zaki; Alan C Hartford; Lesley A Jarvis; Eunice Y Chen; Richard J Comi; Marc S Ernstoff; Huagang Hou; Nadeem Khan; Steven G Swarts; Ann B Flood; Periannan Kuppusamy
Journal:  Acad Radiol       Date:  2014-02       Impact factor: 3.173

10.  Implementation of GPU-accelerated back projection for EPR imaging.

Authors:  Zhiwei Qiao; Gage Redler; Boris Epel; Yuhua Qian; Howard Halpern
Journal:  J Xray Sci Technol       Date:  2015       Impact factor: 1.535

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.