Literature DB >> 18521023

The effect of corneal edema on dynamic contour and goldmann tonometry.

Kirsten E Hamilton1, David C Pye, Lawrence Kao, Nhung Pham, An-Quyen Nguyen Tran.   

Abstract

PURPOSE: To determine the effect of contact lens-induced corneal edema on measurements of intraocular pressure (IOP) using the Pascal dynamic contour tonometer (DCT), compared with the Goldmann tonometer.
METHODS: Thirty young healthy subjects (23.0 +/- 3.0 years) were recruited from the student population at the University of New South Wales. Thick hydroxyethyl methacrylate contact lenses were worn monocularly for 2 hours under closed-eye conditions to induce corneal edema via hypoxia. IOP (Goldmann and Pascal DCT), ocular pulse amplitude (OPA), and central corneal thickness (CCT) were measured in both eyes before and after lens wear. Paired t-tests, Pearson correlation, and Bland-Altman plots were used to identify changes in, and relationships between, these parameters resulting from corneal edema.
RESULTS: Lens wear resulted in statistically significant changes in CCT (+48.3 +/- 14.4 microm, p < 0.001), Goldmann IOP (+1.5 +/- 2.8 mm Hg, p = 0.007), and Pascal DCT IOP (-0.7 +/- 1.1 mm Hg, p = 0.001) but not OPA (0.0 +/- 0.3 mm Hg, p = 0.721, two-tailed paired t-test). The Pascal DCT provided IOP readings that were 1.3 +/- 2.0 mm Hg higher than the Goldmann IOP readings when hydration was normal, but the Goldmann tonometer provided readings that were 0.8 +/- 2.5 mm Hg higher than the Pascal DCT readings when the cornea was edematous. The variation between the two instruments was weakly correlated to the change in CCT (r = -0.261, p = 0.044).
CONCLUSIONS: Contact lens-induced corneal edema caused a small underestimation error in IOP measurements by the Pascal DCT, and an overestimation error in Goldmann tonometry measurements. The OPA measurement provided by the Pascal DCT is insensitive to corneal edema-induced changes in corneal properties.

Entities:  

Mesh:

Year:  2008        PMID: 18521023     DOI: 10.1097/OPX.0b013e3181783a86

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  7 in total

1.  The influence of soft contact lenses on the intraocular pressure measurement.

Authors:  P G Firat; C Cankaya; S Doganay; M Cavdar; S Duman; E Ozsoy; B Koc
Journal:  Eye (Lond)       Date:  2011-11-11       Impact factor: 3.775

2.  Dependence of dynamic contour and Goldmann applanation tonometries on peripheral corneal thickness.

Authors:  Federico Saenz-Frances; Claudia Sanz-Pozo; Lara Borrego-Sanz; Luis Jañez; Laura Morales-Fernandez; Jose Maria Martinez-de-la-Casa; Julian Garcia-Sanchez; Julian Garcia-Feijoo; Enrique Santos-Bueso
Journal:  Int J Ophthalmol       Date:  2017-10-18       Impact factor: 1.779

3.  Goldmann applanation tonometry and dynamic contour tonometry in eyes with elevated intraocular pressure (IOP): comparison in the same eyes after subsequent medical normalization of IOP.

Authors:  Chungkwon Yoo; Young Sub Eom; Yong Yeon Kim
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-07-22       Impact factor: 3.117

4.  The effect of contact lens-induced corneal edema on Goldmann applanation tonometry and dynamic contour tonometry.

Authors:  Jong-Hyun Oh; Chungkwon Yoo; Yong Yeon Kim; Hyo-Myung Kim; Jong-Suk Song
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-10-09       Impact factor: 3.117

5.  Accuracy of dynamic contour tonometry, Goldmann applanation tonometry, and Tono-Pen XL in edematous corneas.

Authors:  George A Kontadakis; Alexandros Pennos; Iro Pentari; George D Kymionis; Ioannis G Pallikaris; Harilaos Ginis
Journal:  Ther Adv Ophthalmol       Date:  2020-06-10

6.  A clinical method for estimating the modulus of elasticity of the human cornea in vivo.

Authors:  David C Pye
Journal:  PLoS One       Date:  2020-01-08       Impact factor: 3.240

7.  Tonometry in corneal edema after cataract surgery: dynamic contour tonometry versus Goldmann applanation tonometry.

Authors:  Anne Herr; Andreas Remky; Thalia Hirsch; Corinna Rennings; Niklas Plange
Journal:  Clin Ophthalmol       Date:  2013-05-03
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.