Literature DB >> 18514886

Removal of a well-fixed trabecular metal monoblock tibial component.

Gregg R Klein1, Harlan B Levine, Mark A Hartzband.   

Abstract

The use of porous tantalum (Trabecular Metal; Zimmer, Inc, Warsaw, Ind) in hip and knee reconstruction has become increasingly popular over the past few years. Widespread clinical use of porous tantalum tibial components for primary total knee arthroplasty has been tempered in part by the perceived difficulty in removing this implant after bone ingrowth has occurred. We present an easy, reproducible, and inexpensive technique for removal of a well-fixed Trabecular Metal Monoblock Tibial Component (Zimmer), which has been used in 4 revision knees. This technique does not require the use of any specialized equipment and results in the production of minimal metallic debris.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18514886     DOI: 10.1016/j.arth.2007.05.004

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  7 in total

1.  Case reports: Tantalum debris dispersion during revision of a tibial component for TKA.

Authors:  Jose Miguel Sanchez Marquez; Nicolas Del Sel; Alejandro Leali; Alejandro González Della Valle
Journal:  Clin Orthop Relat Res       Date:  2008-10-22       Impact factor: 4.176

2.  Early aseptic loosening of a porous tantalum knee prosthesis.

Authors:  D Tigani; G Sabbioni; A Raimondi
Journal:  Chir Organi Mov       Date:  2009-11-06

3.  Trabecular metal in total knee arthroplasty associated with higher knee scores: a randomized controlled trial.

Authors:  Mariano Fernandez-Fairen; Daniel Hernández-Vaquero; Antonio Murcia; Ana Torres; Rafael Llopis
Journal:  Clin Orthop Relat Res       Date:  2013-07-25       Impact factor: 4.176

4.  [Comparison of effectiveness of total knee arthroplasty with tantalum monoblock tibial component and cemented tibial plateau prosthesis in patients of different ages].

Authors:  Yu Jiao; Xiaogang Zhang; Boyong Xu; Guoqing Li; Li Cao
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-12-15

5.  Do porous tantalum implants help preserve bone?: evaluation of tibial bone density surrounding tantalum tibial implants in TKA.

Authors:  Alicia K Harrison; Terence J Gioe; Christine Simonelli; Penny J Tatman; Mary C Schoeller
Journal:  Clin Orthop Relat Res       Date:  2010-01-12       Impact factor: 4.176

6.  Long-term results of a porous tantalum monoblock tibia component: clinical and radiographic results at follow-up of 10 years.

Authors:  Daniel Gerscovich; Catherine Schwing; Anthony Unger
Journal:  Arthroplast Today       Date:  2017-04-07

7.  Removing a well-fixed femoral sleeve during revision total knee arthroplasty.

Authors:  J Ryan Martin; Tyler S Watters; Daniel L Levy; Jason M Jennings; Douglas A Dennis
Journal:  Arthroplast Today       Date:  2016-07-02
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.