Literature DB >> 19894102

Early aseptic loosening of a porous tantalum knee prosthesis.

D Tigani1, G Sabbioni, A Raimondi.   

Abstract

Porous tantalum represents a relatively new solution for primary and revision total knee arthroplasty, offering several unmatched properties. Tantalum is a transition metal, with excellent biocompatibility and bioactivity due to its intrinsic physical and structural characteristics. A widespread clinical use of porous tantalum tibial components for primary total knee arthroplasty has been partly hindered by the difficulty in removing this type of implant after bone in growth, often leading to a significant bone defect. On the contrary, in the case here reported, removal of the trabecular metal tibial component was unexpectedly easy at a 7-month follow-up due to the absence of bone ingrowth but with a complete preservation of the tibial plate bone stock. Causes for the lack of bone ingrowth are discussed.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19894102     DOI: 10.1007/s12306-009-0047-x

Source DB:  PubMed          Journal:  Chir Organi Mov        ISSN: 0009-4749


  17 in total

Review 1.  A porous tantalum trabecular metal: basic science.

Authors:  Robert Cohen
Journal:  Am J Orthop (Belle Mead NJ)       Date:  2002-04

2.  Survivorship analysis of the uncemented porous-coated anatomic knee replacement.

Authors:  C G Moran; I M Pinder; T A Lees; M J Midwinter
Journal:  J Bone Joint Surg Am       Date:  1991-07       Impact factor: 5.284

Review 3.  Experimental and clinical performance of porous tantalum in orthopedic surgery.

Authors:  Brett Russell Levine; Scott Sporer; Robert A Poggie; Craig J Della Valle; Joshua J Jacobs
Journal:  Biomaterials       Date:  2006-06-05       Impact factor: 12.479

4.  Evolution of tibial fixation in total knee arthroplasty.

Authors:  Adolph V Lombardi; Carl C Berasi; Keith R Berend
Journal:  J Arthroplasty       Date:  2007-06       Impact factor: 4.757

Review 5.  Hypersensitivity reactions in total hip arthroplasty.

Authors:  Christoph H Lohmann; Jakob V Nuechtern; Hans-Georg Willert; Sabine Junk-Jantsch; Wolfgang Ruether; Gerald Pflueger
Journal:  Orthopedics       Date:  2007-09       Impact factor: 1.390

6.  Removal of a well-fixed trabecular metal monoblock tibial component.

Authors:  Gregg R Klein; Harlan B Levine; Mark A Hartzband
Journal:  J Arthroplasty       Date:  2007-11-09       Impact factor: 4.757

7.  The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system.

Authors:  F C Ewald
Journal:  Clin Orthop Relat Res       Date:  1989-11       Impact factor: 4.176

8.  Knee arthroplasty using a cementless PCA prosthesis with a porous-coated central tibial stem. Clinical and radiographic review at five years.

Authors:  Y H Kim
Journal:  J Bone Joint Surg Br       Date:  1990-05

9.  Chronic urticaria from tantalum staples.

Authors:  B S Werman; R L Rietschel
Journal:  Arch Dermatol       Date:  1981-07

Review 10.  Metal sensitivity in patients with orthopaedic implants.

Authors:  N Hallab; K Merritt; J J Jacobs
Journal:  J Bone Joint Surg Am       Date:  2001-03       Impact factor: 5.284

View more
  5 in total

Review 1.  Bone loss management in total knee revision surgery.

Authors:  Gabriele Panegrossi; Marco Ceretti; Matteo Papalia; Filippo Casella; Fabio Favetti; Francesco Falez
Journal:  Int Orthop       Date:  2014-01-10       Impact factor: 3.075

Review 2.  Highlighting the advantages and benefits of cementless total knee arthroplasty (Review).

Authors:  Bogdan Uivaraseanu; Cosmin Mihai Vesa; Delia Mirela Tit; Octavian Maghiar; Teodor Andrei Maghiar; Calin Hozan; Aurelia Cristina Nechifor; Tapan Behl; Felicia Liana Andronie-Cioara; Jenel Marian Patrascu; Simona Bungau
Journal:  Exp Ther Med       Date:  2021-11-18       Impact factor: 2.447

3.  Bone ingrowth in well-fixed retrieved porous tantalum implants.

Authors:  Josa A Hanzlik; Judd S Day
Journal:  J Arthroplasty       Date:  2013-03-18       Impact factor: 4.757

4.  Long-term results of a porous tantalum monoblock tibia component: clinical and radiographic results at follow-up of 10 years.

Authors:  Daniel Gerscovich; Catherine Schwing; Anthony Unger
Journal:  Arthroplast Today       Date:  2017-04-07

5.  Enhanced Biocompatibility in Anodic TaO x Nanotube Arrays.

Authors:  Yu-Jin Zeng; Sheng-Chen Twan; Kuan-Wen Wang; Her-Hsiung Huang; Yen-Bin Hsu; Chien-Ying Wang; Ming-Ying Lan; Sheng-Wei Lee
Journal:  Nanoscale Res Lett       Date:  2017-10-03       Impact factor: 4.703

  5 in total