The influence of tip geometry and distance on light-curing efficacy.

Gabriele Corciolani1, Alessandro Vichi, Carel Leon Davidson, Marco Ferrari.   

Abstract

This study investigated the influence of the light guide shape on the polymerization efficacy of a light-activated resin-based composite cured with LED units as a function of the distance between the tip and the restoration. Two different LED units, each with different light guides and shapes, were used. Their ability to cure a single restorative material was investigated. The efficacy of the light-curing system was evaluated by measuring the depth of cure using the Acetone Shake test. Considering the ratio (R) between the entry diameter and the exit diameter of the light guide, the tips with a higher R-value proved to be more efficient if the tip and composite distance (D) was less than 5 mm, while for D > 5 mm, the tips with a lower R-value showed better results. The tip geometry of the tested light guide had a significant influence on the depth of cure of the tested resin composites. Therefore, depending on the distance, the more suitable light guide should be selected, based on the clinical situation. An R-value may be a better descriptor for the light guide shape than words such as "normal" or "turbo."

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18505224     DOI: 10.2341/07-94

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  7 in total

1.  Polymerization pattern characterization within a resin-based composite cured using different curing units at two distances.

Authors:  Afnan O Al-Zain; George J Eckert; Henry Lukic; Spiro Megremis; Jeffrey A Platt
Journal:  Clin Oral Investig       Date:  2019-02-09       Impact factor: 3.573

2.  Influence of light-curing distance on degree of conversion and cytotoxicity of etch-and-rinse and self-etch adhesives.

Authors:  Florian J Wegehaupt; Nancy Lunghi; Georgios N Belibasakis; Thomas Attin
Journal:  BMC Oral Health       Date:  2016-07-07       Impact factor: 2.757

3.  Impact of light-curing distance on the effectiveness of cure of bulk-fill resin-based composites.

Authors:  Rana Abdelbaset Diab; Adrian Ujin Yap; Maria Angela Garcia Gonzalez; Noor Azlin Yahya
Journal:  Saudi Dent J       Date:  2021-01-14

4.  Effect of different curing times and distances on the microhardness of nanofilled resin-based composite restoration polymerized with high-intensity LED light curing units.

Authors:  Haifa Barakah
Journal:  Saudi Dent J       Date:  2021-06-10

5.  Influence of Tip Diameter and Light Spectrum of Curing Units on the Properties of Bulk-Fill Resin Composites.

Authors:  Igor Oliveiros Cardoso; Alexandre Coelho Machado; Luísa de Oliveira Fernandes; Paulo Vinícius Soares; Luís Henrique Araújo Raposo
Journal:  Eur J Dent       Date:  2021-12-14

6.  Evaluation of degree of conversion and hardness of dental composites photo-activated with different light guide tips.

Authors:  Marília Regalado Galvão; Sergei Godeiro Fernandes Rabelo Caldas; Vanderlei Salvador Bagnato; Alessandra Nara de Souza Rastelli; Marcelo Ferrarezi de Andrade
Journal:  Eur J Dent       Date:  2013-01

7.  Light-curing units used in dentistry: factors associated with heat development-potential risk for patients.

Authors:  Mathieu Mouhat; James Mercer; Lina Stangvaltaite; Ulf Örtengren
Journal:  Clin Oral Investig       Date:  2016-10-01       Impact factor: 3.573

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.