| Literature DB >> 34905778 |
Igor Oliveiros Cardoso1, Alexandre Coelho Machado2, Luísa de Oliveira Fernandes1, Paulo Vinícius Soares3, Luís Henrique Araújo Raposo1.
Abstract
OBJECTIVE: The aim of this study was to evaluate the influence of different light-curing units (LCUs) with distinct tip diameters and light spectra for activating bulk-fill resins.Entities:
Year: 2021 PMID: 34905778 PMCID: PMC9339921 DOI: 10.1055/s-0041-1735799
Source DB: PubMed Journal: Eur J Dent
Specifications of the LCU tested
| LCU | Manufacturer | Irradiance | Wavelength emission |
Tip diameter (mm)
|
Tip area (cm
2
)
|
|---|---|---|---|---|---|
| Radii Xpert | SDI, Bayswater, Victoria, Australia | 1,575 mW/cm 2 (standard) | Monowave | 7.8 | 0.48 |
| Valo | Ultradent, Salt Lake City, Utah, United States | 1103 mW/cm 2 (standard) | Multipeak | 9.5 | 0.7 |
Abbreviation: LCU, light-curing unit.
Specifications of the tested RBCs
| Resin composite | Manufacturer | Color | Type | Organic matrix | Filler | Amount of load (wt%/vol%) | Batch no. |
|---|---|---|---|---|---|---|---|
| Amaris | VOCO, Cuxhaven, Germany | TN | Conventional | Bis-GMA, UDMA, TEGDMA | Inorganics fillers in a methacrylate matrix | 80/– | 1829623 |
| Filtek One | 3M ESPE, St. Paul, Minnesota, United States | A2 | Bulk fill | AFM, AUDMA, UDMA, and 1,2-dodecano-DMA (DDMA) | Ytterbium trifluoride, nonaggregated silica, nonaggregated zirconia, zirconia/silica clusters | 76.5/58 | N974887 |
| Aura Bulk Fill | SDI, Bayswater, Victoria, Australia | BKF | Bulk fill | Bis-GMA, UDMA, Bis-EMA, TEGDMA | Silica, signaled barium and glass particles | 74.2/65 | 180143 |
| Tetric Bulk Fill | Ivoclar Vivadent, Schaan, Liechtenstein | IVA | Bulk fill | Bis-GMA, BisEMA and UDMA | Barium aluminum silicate glass, an “Isofiller,” ytterbium fluoride and spherical mixed oxide | 75–77/55 | 94624 |
Abbreviation: RBCs, resin-based composites.
Mean DC% values and standard deviation (±) for control and experimental groups according to LCU and specimen diameter
| Group | Diameter | LCU | DC% | LCU | DC% | ||
|---|---|---|---|---|---|---|---|
| Amaris (CG) | 7 mm | Valo | 47.2 ± 3.6 | – | Radii Xpert | 45.9 ± 3.4 | – |
| 10 mm | 48.6 ± 3.6 | – | 44.9 ± 3.0 | – | |||
| Aura Bulk Fill | 7 mm |
51.2 ± 1.9
| 0.004 |
51.7 ± 3.0
| <0.001 | ||
| 10 mm | 50.4 ± 2.3 | 0.344 |
52.9 ± 2.9
| <0.001 | |||
| Filtek One | 7 mm | 49.7 ± 2.7 | 0.099 | 47.0 ± 2.0 | 0.753 | ||
| 10 mm | 49.6 ± 2.8 | 0.741 |
52.4 ± 2.2
| <0.001 | |||
| Tetric Bulk Fill | 7 mm |
54.8 ± 1.7
| <0.001 |
52.1 ± 3.1
| <0.001 | ||
| 10 mm |
53.5 ± 1.5
| <0.001 |
52.9 ± 2.4
| <0.001 |
Abbreviations: CG, control group; DC, degree of conversion; LCU, light-curing unit.
Indicates significant difference from CG; one-way analysis of variance and Dunnett's test ( p > 0.05).
Mean DC% and standard deviation (±) for bulk-fill RBCs according to LCU and specimen diameter
| Group | Valo | Radii Xpert | ||
|---|---|---|---|---|
| 7 mm | 10 mm | 7 mm | 10 mm | |
| Aura Bulk Fill | 51.2 ± 1.9 | 50.4 ± 2.3 | 51.7 ± 3.0 | 52.9 ± 2.9 |
| Filtek One | 49.7 ± 2.7 | 49.6 ± 2.8 | 47.0 ± 2.0 | 52.4 ± 2.2 |
| Tetric Bulk Fill | 54.8 ± 1.7 | 53.5 ± 1.5 | 52.1 ± 3.1 | 52.9 ± 2.4 |
Abbreviations: DC, degree of conversion; LCU, light-curing unit; RBCs, resin-based composites.
Note: Capital letters indicate significant differences among LCUs (rows: vertical direction). Lowercase letters indicate significant differences among bulk-fill RBCs (columns: horizontal direction), and symbols indicate significant differences between diameters for the same LCU (rows: vertical direction). Tukey's test ( p ˂ 0.05).
Mean KHN values and standard deviation (±) for control and experimental groups according to LCU, specimen diameter, and region of analysis
| Group | Diameter | Region | LCU | KHN | LCU | KHN | ||
|---|---|---|---|---|---|---|---|---|
| Amaris (CG) | 7 mm | Center | Valo | 53.0 ± 4.4 | – | Radii Xpert | 51.3 ± 1.0 | – |
| Periphery | 51.8 ± 3.7 | – | 48.8 ± 0.8 | – | ||||
| 10 mm | Center | 53.2 ± 1.8 | – | 54.3 ± 1.7 | – | |||
| Periphery | 57.6 ± 1.6 | – | 49.4 ± 1.4 | – | ||||
| Aura Bulk Fill | 7 mm | Center |
57.6 ± 2.5
| 0.032 |
58.8 ± 2.3
| <0.001 | ||
| Periphery | 55.3 ± 2.2 | 0.067 |
57.0 ± 1.9
| <0.001 | ||||
| 10 mm | Center |
58.3 ± 2.1
| <0.001 |
57.5 ± 1.7
| <0.001 | |||
| Periphery |
57.6 ± 1.6
| <0.001 |
57.4 ± 3.0
| <0.001 | ||||
| Filtek One | 7 mm | Center |
70.5 ± 0.8
| <0.001 |
69.9 ± 1.7
| <0.001 | ||
| Periphery |
69.4 ± 1.1
| <0.001 |
69.7 ± 0.8
| <0.001 | ||||
| 10 mm | Center |
68.9 ± 2.1
| <0.001 |
69.0 ± 1.1
| <0.001 | |||
| Periphery |
68.5 ± 2.0
| <0.001 |
66.8 ± 1.0
| <0.001 | ||||
| Tetric Bulk Fill | 7 mm | Center |
62.1 ± 0.9
| <0.001 |
59.7 ± 1.7
| <0.001 | ||
| Periphery |
61.7 ± 0.7
| <0.001 |
58.6 ± 1.2
| <0.001 | ||||
| 10 mm | Center |
60.6 ± 1.0
| <0.001 |
58.1 ± 2.6
| <0.001 | |||
| Periphery |
60.0 ± 0.8
| <0.001 |
57.4 ± 1.9
| <0.001 |
Abbreviations: CG, control group; KHN, Knoop hardness; LCU, light-curing unit.
Indicates significant difference from CG; one-way analysis of variance and Dunnett's test ( p > 0.05).
Mean Knoop hardness and standard deviation (±) for bulk-fill RBCs according to LCU, specimen diameter and region of analysis
| Group | Diameter | Valo | Radii Xpert | ||
|---|---|---|---|---|---|
| Center | Periphery | Center | Periphery | ||
| Amaris | 7 mm | 53.0 ± 4.4 | 51.8 ± 3.7 | 51.3 ± 1.0 | 48.8 ± 0.8 |
| 10 mm | 53.2 ± 1.8 | 49.6 ± 1.5 | 54.3 ± 1.7 | 49.4 ± 1.4 | |
| Aura Bulk | 7 mm | 57.6 ± 2.5 | 55.3 ± 2.2 | 58.8 ± 2.3 | 57.0 ± 1.9 |
| 10 mm | 58.3 ± 2.1 | 57.6 ± 1.6 | 57.5 ± 1.7 | 57.4 ± 3.0 | |
| Filtek One | 7 mm | 70.5 ± 0.8 | 69.4 ± 1.1 | 69.9 ± 1.7 | 69.7 ± 0.8 |
| 10 mm | 68.9 ± 2.1 | 68.5 ± 2.0 | 69.0 ± 1.1 | 66.8 ± 1.0 | |
| Tetric Bulk | 7 mm | 62.1 ± 0.9 | 61.7 ± 0.7 | 59.7 ± 1.7 | 58.6 ± 1.2 |
| 10 mm | 60.6 ± 1.0 | 60.0 ± 0.8 | 58.1 ± 2.6 | 57.4 ± 1.9 | |
Abbreviations: DC, degree of conversion; LCU, light-curing unit; RBCs, resin-based composites.
Note: Capital letters indicate significant differences between center and periphery regions (rows: vertical direction). Lowercase letters indicate significant differences between disc diameters (columns: horizontal direction), and symbols indicate significant differences between LCUs for the same region (rows: vertical direction). Tukey's test ( p ˂ 0.05).