Literature DB >> 22391671

Parker Flex-Tip Tube® provides higher intubation success with the Pentax-AWS Airwayscope® despite the AWS tip being inserted into the vallecula.

Akihiro Suzuki1, Tadahisa Ohmura, Akihito Tampo, Yuya Goto, Ou Oikawa, Takayuki Kunisawa, Hiroshi Iwasaki.   

Abstract

The Parker Flex-Tip(®) tube, in combination with the Pentax-Airwayscope(®) (AWS), is anecdotally reported to facilitate intubation when the AWS tip fails to be inserted behind the epiglottis. We examined whether the Parker tube facilitates intubation when the AWS tip is inserted into the vallecula. Forty patients were randomly assigned into either the standard or Parker tube group. Following general anesthesia induction, AWS intubation was attempted with the blade tip inserted into the vallecula. After obtaining an optimal laryngeal view, the tube was advanced toward the glottis. The laryngoscopist allowed additional adjustment of the blade tip direction when the first tube insertion failed because of involvement or folding of the epiglottis resulting from advancement of the tube. The primary outcome was defined as the success rate for intubation and secondary outcome as the time needed for tube placement. The Parker tube provided both a higher intubation success rate (17/20 vs. 4/20, P < 0.01), and a faster intubation time (17 ± 5 s vs. 25 ± 4 s, P < 0.01), than the standard tube. We conclude the use of the Parker tube in combination with the AWS is an optional technique allowing the laryngoscopist to obtain more reliable intubation success despite insertion of the AWS tip into the vallecula.

Entities:  

Mesh:

Year:  2012        PMID: 22391671     DOI: 10.1007/s00540-012-1369-7

Source DB:  PubMed          Journal:  J Anesth        ISSN: 0913-8668            Impact factor:   2.078


  10 in total

1.  Parker Flex-Tip Tube(®) facilitates intubation when the Pentax-AWS(®) fails to reach the larynx.

Authors:  Tadahisa Ohmura; Akihiro Suzuki; Atsushi Kurosawa; Kazuhiro Fujimoto; Takayuki Kunisawa; Hiroshi Iwasaki
Journal:  J Anesth       Date:  2010-08-07       Impact factor: 2.078

2.  Description and first clinical application of AirWay Scope for tracheal intubation.

Authors:  Jun-ichi Koyama; Tatsuro Aoyama; Yoshikazu Kusano; Tatsuya Seguchi; Kyutaro Kawagishi; Tomomi Iwashita; Kazufumi Okamoto; Hiroshi Okudera; Hiroshi Takasuna; Kazuhiro Hongo
Journal:  J Neurosurg Anesthesiol       Date:  2006-10       Impact factor: 3.956

3.  Nasal tracheal intubation improves the success rate when the Airway Scope blade fails to reach the larynx.

Authors:  H Y Lai; A Chen; Y Lee
Journal:  Br J Anaesth       Date:  2008-04       Impact factor: 9.166

4.  Pentax-AWS and tube selection.

Authors:  Akihiro Suzuki; Takayuki Kunisawa; Hiroshi Iwasaki
Journal:  Can J Anaesth       Date:  2007-09       Impact factor: 5.063

5.  Failure of the Airway Scope to reach the larynx.

Authors:  Nobuko Sasano; Hiroki Yamauchi; Yoshihito Fujita
Journal:  Can J Anaesth       Date:  2007-09       Impact factor: 5.063

6.  Approach combining the airway scope and the bougie for minimizing movement of the cervical spine during endotracheal intubation.

Authors:  Ichiro Takenaka; Kazuyoshi Aoyama; Tamao Iwagaki; Hiroshi Ishimura; Yukari Takenaka; Tatsuo Kadoya
Journal:  Anesthesiology       Date:  2009-06       Impact factor: 7.892

7.  Pentax-AWS (Airway Scope) and Airtraq: big difference between two similar devices.

Authors:  Akihiro Suzuki; Nobuko Abe; Tomoki Sasakawa; Takayuki Kunisawa; Osamu Takahata; Hiroshi Iwasaki
Journal:  J Anesth       Date:  2008-05-25       Impact factor: 2.078

8.  The Pentax-AWS is particularly suitable for facilitating intubation in edentulous geriatric patients.

Authors:  Kunihiko Yamamoto; Akihiro Suzuki; Yuki Toyama; Tomoki Sasakawa; Takayuki Kunisawa; Osamu Takahata; Hiroshi Iwasaki
Journal:  J Anesth       Date:  2009-08-14       Impact factor: 2.078

9.  Use of the Pentax-AWS in 293 patients with difficult airways.

Authors:  Takashi Asai; Eugene H Liu; Sanae Matsumoto; Yoshihiro Hirabayashi; Norimasa Seo; Akihiro Suzuki; Takashi Toi; Kazumasa Yasumoto; Yasuhisa Okuda
Journal:  Anesthesiology       Date:  2009-04       Impact factor: 7.892

10.  The Pentax-AWS((R)) rigid indirect video laryngoscope: clinical assessment of performance in 320 cases.

Authors:  A Suzuki; Y Toyama; N Katsumi; T Kunisawa; R Sasaki; K Hirota; J J Henderson; H Iwasaki
Journal:  Anaesthesia       Date:  2008-06       Impact factor: 6.955

  10 in total
  3 in total

1.  Advantage of Parker Flex-tip Tube™ in endotracheal intubation using AirwayScope™ videolaryngoscope.

Authors:  Hiroyuki Kinoshita
Journal:  J Anesth       Date:  2012-10-18       Impact factor: 2.078

2.  Performance of a Parker Flex-Tip tube(®) for intubation with the Pentax-AirwayScope(®).

Authors:  Xue Hua Chen; Di Wu; Fu Shan Xue
Journal:  J Anesth       Date:  2012-09-19       Impact factor: 2.078

3.  In reply: advantage of Parker Flex-tip Tube(®) in endotracheal intubation using AirwayScope(®) videolaryngoscope.

Authors:  Akihiro Suzuki; Akihito Tampo; Takayuki Kunisawa
Journal:  J Anesth       Date:  2012-10-19       Impact factor: 2.078

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.