OBJECTIVE: To determine whether the placement of an implantable cardioverter-defibrillator (ICD) lead in the right ventricular outflow tract (RVOT) has the same defibrillation threshold (DFT) as the right ventricular apex (RVA).
BACKGROUND: Right ventricular ICD leads have usually been placed in the RVA. Development of active fixation technology has allowed the placement of these leads in alternate locations such as the RVOT.
METHODS: At time of device implantation, 26 patients with either ischemic or dilated cardiomyopathy underwent DFT testing in both the RVA and RVOT using a binary search algorithm.
RESULTS: Placement of the lead in the RVA had a mean DFT of 7.6 +/- 2.8 J while the placement of the lead in the RVOT had a mean DFT of 10.3 +/- 3.0 J. The median (25th and 75th percentiles) DFTs in the RVA and RVOT were 7.5 J (6 and 11 J) and 11 J (9 and 14 J), respectively (p = 0.0002).
CONCLUSIONS: Placement of the right ventricular lead in the RVA has a significantly lower DFT than placement of the lead in the RVOT.

Entities:  

Mesh:

Year:  2008        PMID: 18470602     DOI: 10.1007/s10840-008-9254-x

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  31 in total

Review 1.  Defibrillation threshold: clinical utility and therapeutic implications.

Authors:  I Singer; D Lang
Journal:  Pacing Clin Electrophysiol       Date:  1992-06       Impact factor: 1.976

2.  TRANSTHORACIC VENTRICULAR DEFIBRILLATION WITH SQUARE-WAVE STIMULI: ONE-HALF CYCLE, ONE CYCLE, AND MULTICYCLE WAVEFORMS.

Authors:  J C SCHUDER; H STOECKLE; A M DOLAN
Journal:  Circ Res       Date:  1964-09       Impact factor: 17.367

3.  Effect of amiodarone and sotalol on ventricular defibrillation threshold: the optimal pharmacological therapy in cardioverter defibrillator patients (OPTIC) trial.

Authors:  Stefan H Hohnloser; Paul Dorian; Robin Roberts; Michael Gent; Carsten W Israel; Eric Fain; Jean Champagne; Stuart J Connolly
Journal:  Circulation       Date:  2006-07-03       Impact factor: 29.690

4.  Effect of shock polarity on biphasic defibrillation thresholds using an active pectoral lead system.

Authors:  M R Olsovsky; S R Shorofsky; M R Gold
Journal:  J Cardiovasc Electrophysiol       Date:  1998-04

5.  High defibrillation thresholds in transvenous biphasic implantable defibrillators: clinical predictors and prognostic implications.

Authors:  Himanshu H Shukla; Greg C Flaker; Vinod Jayam; David Roberts
Journal:  Pacing Clin Electrophysiol       Date:  2003-01       Impact factor: 1.976

6.  Nonthoracotomy implantation of cardioverter defibrillators: preliminary experience with a defibrillation lead placed at the right ventricular outflow tract.

Authors:  A S Tang; P Hendry; W Goldstein; M S Green; M Luce
Journal:  Pacing Clin Electrophysiol       Date:  1996-06       Impact factor: 1.976

7.  Increased risk of progressive hemodynamic deterioration in advanced heart failure patients requiring permanent pacemakers.

Authors:  L A Saxon; W G Stevenson; H R Middlekauff; L W Stevenson
Journal:  Am Heart J       Date:  1993-05       Impact factor: 4.749

8.  Cardioverter-defibrillator implantation in high-risk patients with hypertrophic cardiomyopathy.

Authors:  Adrian K Almquist; Julia V Montgomery; Tammy S Haas; Barry J Maron
Journal:  Heart Rhythm       Date:  2005-08       Impact factor: 6.343

9.  Probability of successful defibrillation at multiples of the defibrillation energy requirement in patients with an implantable defibrillator.

Authors:  S A Strickberger; E G Daoud; T Davidson; R Weiss; F Bogun; B P Knight; M Bahu; R Goyal; K C Man; F Morady
Journal:  Circulation       Date:  1997-08-19       Impact factor: 29.690

10.  Clinical characteristics and outcome of patients with high defibrillation thresholds. A multicenter study.

Authors:  A E Epstein; K A Ellenbogen; K A Kirk; G N Kay; S M Dailey; V J Plumb
Journal:  Circulation       Date:  1992-10       Impact factor: 29.690

View more
  2 in total

1.  Rationale and design of the SPICE study-septal positioning of ventricular ICD electrodes.

Authors:  Christof Kolb; Stylianos Tzeis; George Andrikopoulos; Stefan Asbach; Bernd Lemke; Claudius Hansen; Isabel Deisenhofer; Bernhard Zrenner; Frank Birkenhauer; Panos E Vardas
Journal:  J Interv Card Electrophysiol       Date:  2011-05-31       Impact factor: 1.900

2.  High defibrillation threshold: the science, signs and solutions.

Authors:  Sony Jacob; Victorio Pidlaoan; Jaspreet Singh; Aditya Bharadwaj; Mehul B Patel; Antonio Carrillo
Journal:  Indian Pacing Electrophysiol J       Date:  2010-01-07
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.