Literature DB >> 18460844

Contrast-enhanced MR imaging of metastatic brain tumor at 3 tesla: utility of T(1)-weighted SPACE compared with 2D spin echo and 3D gradient echo sequence.

Tomohiro Komada1, Shinji Naganawa, Hiroshi Ogawa, Masaya Matsushima, Seiji Kubota, Hisashi Kawai, Hiroshi Fukatsu, Mitsuru Ikeda, Minako Kawamura, Yasuo Sakurai, Katsuya Maruyama.   

Abstract

We evaluated the newly developed whole-brain, isotropic, 3-dimensional turbo spin-echo imaging with variable flip angle echo train (SPACE) for contrast-enhanced T(1)-weighted imaging in detecting brain metastases at 3 tesla (T). Twenty-two patients with suspected brain metastases underwent postcontrast study with SPACE, magnetization-prepared rapid gradient-echo (MP-RAGE), and 2-dimensional T(1)-weighted spin echo (2D-SE) imaging at 3T. We quantitatively compared SPACE, MP-RAGE, and 2D-SE images by using signal-to-noise ratios (SNRs) for gray matter (GM) and white matter (WM) and contrast-to-noise ratios (CNRs) for GM-to-WM, lesion-to-GM, and lesion-to-WM. Two blinded radiologists evaluated the detection of brain metastases by segment-by-segment analysis and continuously-distributed test. The CNR between GM and WM was significantly higher on MP-RAGE images than on SPACE images (P<0.01). The CNRs for lesion-to-GM and lesion-to-WM were significantly higher on SPACE images than on MP-RAGE images (P<0.01). There was no significant difference in each sequence in detection of brain metastases by segment-by-segment analysis and the continuously-distributed test. However, in some cases, the lesions were easier to detect in SPACE images than in other sequences, and also the vascular signals, which sometimes mimic lesions in MP-RAGE and 2D-SE images, were suppressed in SPACE images. In detection of brain metastases at 3T magnetic resonance (MR) imaging, SPACE imaging may provide an effective, alternative approach to MP-RAGE imaging for 3D T(1)-weighted imaging.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18460844     DOI: 10.2463/mrms.7.13

Source DB:  PubMed          Journal:  Magn Reson Med Sci        ISSN: 1347-3182            Impact factor:   2.471


  29 in total

1.  Brain Tumor-Enhancement Visualization and Morphometric Assessment: A Comparison of MPRAGE, SPACE, and VIBE MRI Techniques.

Authors:  L Danieli; G C Riccitelli; D Distefano; E Prodi; E Ventura; A Cianfoni; A Kaelin-Lang; M Reinert; E Pravatà
Journal:  AJNR Am J Neuroradiol       Date:  2019-06-20       Impact factor: 3.825

2.  Simple method for whole-brain volumetric T(1)-weighted turbo spin-echo imaging.

Authors:  Masami Yoneyama; Masanobu Nakamura; Makoto Obara; Takashi Namiki; Atsushi Takemura; Satoshi Tatsuno; Seishi Sawano
Journal:  Radiol Phys Technol       Date:  2013-12-04

Review 3.  European Society for Paediatric Oncology (SIOPE) MRI guidelines for imaging patients with central nervous system tumours.

Authors:  Shivaram Avula; Andrew Peet; Giovanni Morana; Paul Morgan; Monika Warmuth-Metz; Tim Jaspan
Journal:  Childs Nerv Syst       Date:  2021-05-10       Impact factor: 1.475

4.  Deep-Learning Detection of Cancer Metastases to the Brain on MRI.

Authors:  Min Zhang; Geoffrey S Young; Huai Chen; Jing Li; Lei Qin; J Ricardo McFaline-Figueroa; David A Reardon; Xinhua Cao; Xian Wu; Xiaoyin Xu
Journal:  J Magn Reson Imaging       Date:  2020-03-13       Impact factor: 4.813

5.  Contrast enhancement of intracranial lesions at 1.5 T: comparison among 2D spin echo, black-blood (BB) Cube, and BB Cube-FLAIR sequences.

Authors:  SungWoon Im; Ryuichiro Ashikaga; Yukinobu Yagyu; Tetsuya Wakayama; Mitsuharu Miyoshi; Tomoko Hyodo; Izumi Imaoka; Seishi Kumano; Kazunari Ishii; Takamichi Murakami
Journal:  Eur Radiol       Date:  2015-05-01       Impact factor: 5.315

6.  Effects of wear time differences of removable functional appliances in class II patients: prospective MRI study of TMJ and masticatory muscle changes.

Authors:  Emre Cesur; Orhan Özdiler; Ayşegül Köklü; Kaan Orhan; Umut Seki
Journal:  Oral Radiol       Date:  2019-03-12       Impact factor: 1.852

7.  Comparison of lesion enhancement between BB Cube and 3D-SPGR images for brain tumors with 1.5-T magnetic resonance imaging.

Authors:  Hirokazu Hasegawa; Ryuichiro Ashikaga; Kaoru Okajima; Tetsuya Wakayama; Mitsuharu Miyoshi; Yasumasa Nishimura; Takamichi Murakami
Journal:  Jpn J Radiol       Date:  2017-05-24       Impact factor: 2.374

8.  Whole-brain black-blood imaging with magnetization-transfer prepared spin echo-like contrast: a novel sequence for contrast-enhanced brain metastasis screening at 3T.

Authors:  Masami Yoneyama; Masanobu Nakamura; Takashi Tabuchi; Atsushi Takemura; Makoto Obara; Satoshi Tatsuno; Seishi Sawano
Journal:  Radiol Phys Technol       Date:  2013-05-05

9.  Usefulness of the Delay Alternating with Nutation for Tailored Excitation Pulse with T1-Weighted Sampling Perfection with Application-Optimized Contrasts Using Different Flip Angle Evolution in the Detection of Cerebral Metastases: Comparison with MPRAGE Imaging.

Authors:  D Kim; Y J Heo; H W Jeong; J W Baek; J-Y Han; J Y Lee; S-C Jin; H J Baek
Journal:  AJNR Am J Neuroradiol       Date:  2019-08-01       Impact factor: 3.825

10.  Usefulness of contrast-enhanced T1-weighted sampling perfection with application-optimized contrasts by using different flip angle evolutions in detection of small brain metastasis at 3T MR imaging: comparison with magnetization-prepared rapid acquisition of gradient echo imaging.

Authors:  Y Kato; S Higano; H Tamura; S Mugikura; A Umetsu; T Murata; S Takahashi
Journal:  AJNR Am J Neuroradiol       Date:  2009-02-12       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.