Pressure pulse contour-derived stroke volume and cardiac output in the morbidly obese patient.

Donald P Bernstein1.   

Abstract

BACKGROUND: The pressure pulse contour method for measuring stroke volume (SV) and cardiac output (CO) has come of age. Various methods have been proposed, but at this time no single technique has shown clear superiority over the others. This commentary and review discusses the various methods, and particularly the pressure recording analytical method (PRAM). Dissection of the method shows that vascular wall abnormalities, which are not unique to the morbidly obese state, represent one more biophysical perturbation causing inaccuracy in stroke volume and cardiac output determination. As PRAM is an uncalibrated method, its accuracy depends on certain assumptions that may not fully explain the multitude of combinations and permutations that define pulsatile blood flow; specifically, the area under the pressure curve during systole and the morphologic characteristics of the waveform throughout the cardiac cycle. As a result of incomplete theory, referenced specifically to the morbidly obese individual, PRAM does not faithfully mimic established reference standards of flow; it systematically underestimates stroke volume and cardiac output. Field equations, that is, equations that are applicable over the full gamut of hemodynamic conditions and vascular pathology, are analytically derived truisms. They require input variables that satisfy the natural state of affairs. To realize this state of absolute biophysical bliss, these variables should ideally be measured. Unfortunately, because of the constraints of practicality, shortcuts to the absolute truth are obligatorily required. As a result, pressure pulse contour methods have evolved that employ curve analysis and neural networking techniques, providing uncalibrated facsimiles of SV and CO.

Entities:  

Mesh:

Year:  2008        PMID: 18443892     DOI: 10.1007/s11695-007-9378-6

Source DB:  PubMed          Journal:  Obes Surg        ISSN: 0960-8923            Impact factor:   4.129


  21 in total

1.  Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instability.

Authors:  Oliver Gödje; Kerstin Höke; Alwin E Goetz; Thomas W Felbinger; Daniel A Reuter; Bruno Reichart; Reinhard Friedl; Andreas Hannekum; Ulrich J Pfeiffer
Journal:  Crit Care Med       Date:  2002-01       Impact factor: 7.598

2.  Cardiac function during laparoscopic vs open gastric bypass.

Authors:  N T Nguyen; H S Ho; N W Fleming; P Moore; S J Lee; C D Goldman; C J Cole; B M Wolfe
Journal:  Surg Endosc       Date:  2001-10-05       Impact factor: 4.584

3.  Semi-invasive monitoring of cardiac output by a new device using arterial pressure waveform analysis: a comparison with intermittent pulmonary artery thermodilution in patients undergoing cardiac surgery.

Authors:  J Mayer; J Boldt; T Schöllhorn; K D Röhm; A M Mengistu; S Suttner
Journal:  Br J Anaesth       Date:  2007-01-11       Impact factor: 9.166

4.  The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new model.

Authors:  G J Langewouters; K H Wesseling; W J Goedhard
Journal:  J Biomech       Date:  1984       Impact factor: 2.712

5.  Hemodynamic changes during laparoscopic gastroplasty in morbidly obese patients.

Authors:  L Dumont; M Mattys; C Mardirosoff; V Picard; J L Allé; J Massaut
Journal:  Obes Surg       Date:  1997-08       Impact factor: 4.129

6.  A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients.

Authors:  J R Jansen; J J Schreuder; J P Mulier; N T Smith; J J Settels; K H Wesseling
Journal:  Br J Anaesth       Date:  2001-08       Impact factor: 9.166

7.  Hemodynamic changes during laparoscopic gastric bypass procedures.

Authors:  Dominick Artuso; Michael Wayne; Sebastiano Cassaro; Thomas Cerabona; Julio Teixeira; Robert Grossi
Journal:  Arch Surg       Date:  2005-03

8.  Assessment of cardiac output from systemic arterial pressure in humans.

Authors:  Salvatore M Romano; Massimo Pistolesi
Journal:  Crit Care Med       Date:  2002-08       Impact factor: 7.598

9.  Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require calibration.

Authors:  Gerard R Manecke; William R Auger
Journal:  J Cardiothorac Vasc Anesth       Date:  2006-10-24       Impact factor: 2.628

Review 10.  Cardiovascular adaptation to obesity and hypertension.

Authors:  C J Lavie; F H Messerli
Journal:  Chest       Date:  1986-08       Impact factor: 9.410

View more
  2 in total

1.  Response to Dr. Bernstein's review: pressure pulse contour-derived stroke volume and cardiac output in the morbidly obese patient.

Authors:  Francesco Forfori; Salvatore Mario Romano; Tania Balderi; Marco Anselmino; Francesco Giunta
Journal:  Obes Surg       Date:  2008-10-23       Impact factor: 4.129

2.  Pulse-contour derived cardiac output measurements in morbid obesity: influence of actual, ideal and adjusted bodyweight.

Authors:  Chantal A Boly; Pieter Schraverus; Floris van Raalten; Jan-Willem Coumou; Christa Boer; Simone van Kralingen
Journal:  J Clin Monit Comput       Date:  2017-08-18       Impact factor: 2.502

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.