Literature DB >> 20386890

Decreased CSF-flow artefacts in T2 imaging of the cervical spine with periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER/BLADE).

Andreas Ragoschke-Schumm1, Peter Schmidt, Julia Schumm, Georg Reimann, Hans-Joachim Mentzel, Werner A Kaiser, Thomas E Mayer.   

Abstract

INTRODUCTION: The cervical spine is prone to artefacts in T2 MR-imaging due to patient movements and cerebrospinal fluid flow. The periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER/BLADE) acquisition method was developed to reduce motion artefacts. We sought to determine if T2-BLADE is superior to T2-TSE with conventional k-space reading.
METHODS: Twenty-five patients were examined using a 1.5 T MR-scanner. T2-weighted imaging of the cervical spine in sagittal and axial orientation using conventional or BLADE k-space reading was performed. Spinal cord, subarachnoid space, vertebrae and discs were evaluated by two independent observers using a scale from 0 (non-diagnostic) to 3 (excellent). Interobserver correlation was assessed as Cohen's kappa. Results of Mann-Whitney U test with p < 0.05 were regarded as significant. Furthermore, the investigators were asked for subjective evaluation in consensus.
RESULTS: Overall interobserver accuracy of κ = 0.91 was obtained. Comparison of sagittal images showed better values for all investigated structures in T2-BLADE: spinal cord (TSE/BLADE: 1.52/2.04; p < 0.001), subarachnoid space (1.36/2.06; p < 0.001) and vertebrae/discs (1.66/2.86; p < 0.001). Comparison of axial images showed better values in T2-BLADE for spinal cord (1.68/1.86; p = 0.149) and vertebrae/discs (1.0/1.96: p < 0.001) while subarachnoid space was better to be evaluated in conventional T2-TSE (1.94/1.12; p < 0.001). In sagittal orientation, motion- and CSF-flow artefacts were reduced in T2-BLADE. In axial orientation, however, CSF-flow artefacts were pronounced in T2-BLADE.
CONCLUSION: The image quality of the sagittal T2-BLADE sequences was significantly better than the T2-TSE and acquired in less time. In axial orientation, increased CSF-flow artefacts may reduce accuracy of structures in the subarachnoid space.

Entities:  

Mesh:

Year:  2010        PMID: 20386890     DOI: 10.1007/s00234-010-0691-8

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  16 in total

1.  Reduction of motion artifacts in magnetic resonance imaging of the neck and cervical spine by long-term averaging.

Authors:  J Seitz; M Strotzer; M Völk; P Held; B Djavidani; W R Nitz; S Feuerbach
Journal:  Invest Radiol       Date:  2000-06       Impact factor: 6.016

2.  Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging.

Authors:  J G Pipe
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

3.  PROPELLER diffusion-weighted magnetic resonance imaging of acute spinal epidural hematoma.

Authors:  H Fujiwara; K Oki; S Momoshima; S Kuribayashi
Journal:  Acta Radiol       Date:  2005-08       Impact factor: 1.990

4.  Depiction of the cranial nerves within the brain stem with use of PROPELLER multishot diffusion-weighted imaging.

Authors:  M Adachi; H Kabasawa; E Kawaguchi
Journal:  AJNR Am J Neuroradiol       Date:  2008-02-07       Impact factor: 3.825

5.  Multishot diffusion-weighted SPLICE PROPELLER MRI of the abdomen.

Authors:  Jie Deng; Reed A Omary; Andrew C Larson
Journal:  Magn Reson Med       Date:  2008-05       Impact factor: 4.668

6.  Normal flow patterns of intracranial and spinal cerebrospinal fluid defined with phase-contrast cine MR imaging.

Authors:  D R Enzmann; N J Pelc
Journal:  Radiology       Date:  1991-02       Impact factor: 11.105

7.  Fast spin echo vs conventional spin echo in cervical spine imaging.

Authors:  A R Gillams; J A Soto; A P Carter
Journal:  Eur Radiol       Date:  1997       Impact factor: 5.315

8.  Improved image quality and detection of acute cerebral infarction with PROPELLER diffusion-weighted MR imaging.

Authors:  Kirsten P Forbes; James G Pipe; John P Karis; Joseph E Heiserman
Journal:  Radiology       Date:  2002-11       Impact factor: 11.105

9.  BLADE in sagittal T2-weighted MR imaging of the cervical spine.

Authors:  C Fellner; C Menzel; F A Fellner; C Ginthoer; N Zorger; A Schreyer; E M Jung; S Feuerbach; T Finkenzeller
Journal:  AJNR Am J Neuroradiol       Date:  2009-11-26       Impact factor: 3.825

10.  Contrast-enhanced MR imaging of the brain using T1-weighted FLAIR with BLADE compared with a conventional spin-echo sequence.

Authors:  Shinji Naganawa; Hiroko Satake; Shingo Iwano; Hisashi Kawai; Seiji Kubota; Tomohiro Komada; Minako Kawamura; Yasuo Sakurai; Hiroshi Fukatsu
Journal:  Eur Radiol       Date:  2007-10-09       Impact factor: 5.315

View more
  2 in total

1.  Elimination of motion and pulsation artifacts using BLADE sequences in shoulder MR imaging.

Authors:  E Lavdas; M Vlychou; E Zaloni; K Vassiou; A Tsagkalis; Z Dailiana; I Fezoulidis
Journal:  Skeletal Radiol       Date:  2015-08-26       Impact factor: 2.199

2.  Magnetic Resonance Imaging in Cervical Spine Trauma: More Than Soft Tissue Illustration.

Authors:  George Fotakopoulos; Alexandros G Brotis; Konstantinos N Fountas
Journal:  Cureus       Date:  2022-01-22
  2 in total