Literature DB >> 18422713

Biomechanical aspects of primary implant stability: a human cadaver study.

Ilser Turkyilmaz1, Lars Sennerby, Edwin A McGlumphy, Tolga F Tözüm.   

Abstract

BACKGROUND: The quality of bone is an important factor in the successful implant treatment, and it is evident that higher implant failure is more likely in poor quality of bone. The primary stability of oral implants related to resistance to micromotion during healing is influenced by bone quality, surgical technique, and implant design. PURPOSES: The aims of this biomechanical study were to explore the effect of bone quality on initial intraosseous stability of implants, and to determine the correlations between the bone quality and implant stability parameters.
MATERIALS AND METHODS: Twenty-four implants (Neoss Ltd., Mölnlycke, Sweden) were placed into anterior and posterior regions of three human cadaver mandibles. The bone densities of implant recipient sites were preoperatively determined using computerized tomography (CT) in Hounsfield unit (HU). The maximum insertion torque values were recorded, and primary implant stability measurements were noninvasively performed by means of resonance frequency analysis (RFA).
RESULTS: The bone density values ranged from -267 HU to 553 HU. It was found that mean bone density, insertion torque, and RFA values were 113 +/- 270 HU, 41.9 +/- 5 Ncm, and 70 +/- 7 implant stability quotient (ISQ), respectively. Statistically significant correlations were found between bone density and insertion torque values (r = 0.690, p < .001); bone density and ISQ values (r = 0.557, p < .05); and insertion torque and ISQ values (r = 0.853, p < .001).
CONCLUSION: CT is a useful tool to assess bone quantity and quality in implant recipient sites, and bone density has a prevailing effect on implant stability at placement.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18422713     DOI: 10.1111/j.1708-8208.2008.00097.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  20 in total

1.  The role of CT analyses of the sternal end of the clavicle and the first costal cartilage in age estimation.

Authors:  Petar Milenkovic; Marija Djuric; Petar Milovanovic; Ksenija Djukic; Vladimir Zivkovic; Slobodan Nikolic
Journal:  Int J Legal Med       Date:  2014-06-24       Impact factor: 2.686

Review 2.  Diagnostic imaging of trabecular bone microstructure for oral implants: a literature review.

Authors:  N Ibrahim; A Parsa; B Hassan; P van der Stelt; D Wismeijer
Journal:  Dentomaxillofac Radiol       Date:  2013       Impact factor: 2.419

3.  CT-based evaluation of volumetric bone density in fragility fractures of the pelvis-a matched case-control analysis.

Authors:  D Schönenberg; R Guggenberger; D Frey; H-C Pape; H-P Simmen; G Osterhoff
Journal:  Osteoporos Int       Date:  2017-11-13       Impact factor: 4.507

4.  3D full-field strain in bone-implant and bone-tooth constructs and their morphological influential factors.

Authors:  Yuxiao Zhou; Chujie Gong; Mehran Hossaini-Zadeh; Jing Du
Journal:  J Mech Behav Biomed Mater       Date:  2020-05-19

5.  Biological evaluation and finite-element modeling of porous poly(para-phenylene) for orthopaedic implants.

Authors:  Hyunhee Ahn; Ravi R Patel; Anthony J Hoyt; Angela S P Lin; F Brennan Torstrick; Robert E Guldberg; Carl P Frick; R Dana Carpenter; Christopher M Yakacki; Nick J Willett
Journal:  Acta Biomater       Date:  2018-03-18       Impact factor: 8.947

6.  Biomechanics and strain mapping in bone as related to immediately-loaded dental implants.

Authors:  Jing Du; Ji-Hyun Lee; Andrew T Jang; Allen Gu; Mehran Hossaini-Zadeh; Richard Prevost; Donald A Curtis; Sunita P Ho
Journal:  J Biomech       Date:  2015-06-19       Impact factor: 2.712

7.  Determination of the dynamics of healing at the tissue-implant interface by means of microcomputed tomography and functional apparent moduli.

Authors:  Po-Chun Chang; Yang-Jo Seol; Steven A Goldstein; William V Giannobile
Journal:  Int J Oral Maxillofac Implants       Date:  2013 Jan-Feb       Impact factor: 2.804

Review 8.  Evaluation of functional dynamics during osseointegration and regeneration associated with oral implants.

Authors:  Po-Chun Chang; Niklaus P Lang; William V Giannobile
Journal:  Clin Oral Implants Res       Date:  2010-01       Impact factor: 5.977

9.  In vitro evaluation of resonance frequency analysis values to different implant contact ratio and stiffness of surrounding material.

Authors:  Mu-Seung Kwak; Seok-Gyu Kim
Journal:  J Adv Prosthodont       Date:  2013-11-28       Impact factor: 1.904

10.  An ex vivo model in human femoral heads for histopathological study and resonance frequency analysis of dental implant primary stability.

Authors:  Pedro Hernández-Cortés; Alberto Monje; Pablo Galindo-Moreno; Andrés Catena; Inmaculada Ortega-Oller; José Salas-Pérez; Francisco Mesa; Rafael Gómez-Sánchez; Mariano Aguilar; David Aguilar; Francisco O'Valle
Journal:  Biomed Res Int       Date:  2014-06-04       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.