Literature DB >> 18379799

Revision of failed acetabular components utilizing a cementless oblong cup: an average 9-year follow-up study.

Georg Köster1, Sabine Rading.   

Abstract

INTRODUCTION: Failure of acetabular components often leads to bone loss with extensive elongated defects in the surrounding bone. In these cases, reconstruction is challenging and stable fixation of the revision implant difficult. The use of an oblong cup has been described as an option for acetabular reconstruction in such revisions. We report the first long-term results obtained with this implant to date.
MATERIALS AND METHODS: Fifty-six longitudinal oblong revision cups (LOR) were evaluated clinically and radiologically after a follow-up of 8-12 years (average 9 years). The defects treated with the LOR cup ranged from Paprosky type 1-3. Allogenic cancellous bone chips were additionally used in 31 reconstructions to fill cavitary defects.
RESULTS: Based on radiological criteria, 50 acetabular implants underwent osseointegration without any definitive signs of loosening; 2 consistently exhibited zonal radiolucent lines that were always smaller than 2 mm, 1 migrated by around 3 mm. None of these cases exhibited any clinical symptoms. In 11 cases where acetabular defects manifested postoperatively, 8 were remodeled completely and 3 partially at final follow-up. Three revision implants migrated farther than 5 mm and had to be revised before 32-month follow-up. In addition, 1 septic implant failure occurred. After an average follow-up of 9 years, 93% of the investigated implants remained in situ without further revision and 95% without aseptic implant failure.
CONCLUSION: This 12-year clinical study demonstrates that the LOR cup offers a successful concept for the revision of failed acetabular components that also promotes the biological reconstruction of bony defects. Compared with other methods with similarly long follow-ups, our long-term results prove this procedure has a very low rate of revision and aseptic implant failure.

Entities:  

Mesh:

Year:  2008        PMID: 18379799     DOI: 10.1007/s00402-008-0624-8

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  6 in total

1.  Long-term results for minor column allografts in revision hip arthroplasty.

Authors:  Paul T H Lee; Guy Raz; Oleg A Safir; David J Backstein; Allan E Gross
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

2.  [Treatment of acetabular bone defects in revision hip arthroplasty using the Revisio-System].

Authors:  M Hoberg; B M Holzapfel; A F Steinert; F Kratzer; M Walcher; M Rudert
Journal:  Orthopade       Date:  2017-02       Impact factor: 1.087

3.  [Standardized reconstruction of acetabular bone defects using the cranial socket system].

Authors:  Maximilian Rudert; Boris Michael Holzapfel; Florian Kratzer; Reiner Gradinger
Journal:  Oper Orthop Traumatol       Date:  2010-07       Impact factor: 1.154

4.  Mid-term results of revision total hip arthroplasty using the oval-shaped uncemented Trč-Cingr cup.

Authors:  Eduard Šťastný; Tomáš Trč; Milan Handl; Petr Kos; Jakub Kautzner; Theodoros Philippou; Jiří Lisý
Journal:  Int Orthop       Date:  2014-01-16       Impact factor: 3.075

5.  Structural allograft as an option for treating infected hip arthroplasty with massive bone loss.

Authors:  Paul T H Lee; Robert A Clayton; Oleg A Safir; David J Backstein; Allan E Gross
Journal:  Clin Orthop Relat Res       Date:  2011-04       Impact factor: 4.176

6.  [Acetabular reinforcement rings in revision total hip arthroplasty: midterm results in 298 cases].

Authors:  U J Schlegel; R G Bitsch; M Pritsch; P R Aldinger; H Mau; S J Breusch
Journal:  Orthopade       Date:  2008-09       Impact factor: 1.087

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.