OBJECTIVE: To determine the reliability of estimating arterial CO(2) pressure (PaCO(2)) using a recently introduced transcutaneous CO(2) pressure (PtcCO(2)) monitor in severe obese patients. DESIGN: Observational and interventional study. SETTING: District hospital with respiratory ward and bariatric surgery unit. PATIENTS AND METHODS: PtcCO(2) was measured in 35 obese patients with varied pathology, including chronic obstructive pulmonary disease, obstructive sleep apnea syndrome and hypoventilation syndrome. Ten minutes after the probe had been attached to an earlobe, PtcCO(2) was recorded immediately before arterial blood sampling. The PtcCO(2) and PaCO(2) values obtained with two methods were compared by Bland-Altman analysis. In a subgroup of 18 obese patients with chronic obstructive pulmonary disease and/or obstructive sleep apnea syndrome with moderate to severe hypercapnia both PtcCO(2) and PaCO(2) were re-evaluated during continuous positive airways pressure (CPAP) or bi-level positive airway pressure (Bi-PAP) treatment. RESULTS: The mean difference between PaCO(2) and PtcCO(2) was -1.4 mmHg, and the standard deviation of the difference was 1.3 mmHg. Bland-Altman analysis showed generally good agreement between the two methods with a 95% limit of agreement of -4 to 1.1. The agreement between methods did not significantly change before and during cPAP or Bi-PAP treatment in hypercapnic patients. CONCLUSIONS: The accuracy of estimation of PaCO(2) by transcutaneous monitoring was generally good in comparison with standard arterial blood gases examination. The device appears to be promising for use in obese patients to evaluate abnormalities in their alveolar ventilation.
OBJECTIVE: To determine the reliability of estimating arterial CO(2) pressure (PaCO(2)) using a recently introduced transcutaneous CO(2) pressure (PtcCO(2)) monitor in severe obesepatients. DESIGN: Observational and interventional study. SETTING: District hospital with respiratory ward and bariatric surgery unit. PATIENTS AND METHODS: PtcCO(2) was measured in 35 obesepatients with varied pathology, including chronic obstructive pulmonary disease, obstructive sleep apnea syndrome and hypoventilation syndrome. Ten minutes after the probe had been attached to an earlobe, PtcCO(2) was recorded immediately before arterial blood sampling. The PtcCO(2) and PaCO(2) values obtained with two methods were compared by Bland-Altman analysis. In a subgroup of 18 obesepatients with chronic obstructive pulmonary disease and/or obstructive sleep apnea syndrome with moderate to severe hypercapnia both PtcCO(2) and PaCO(2) were re-evaluated during continuous positive airways pressure (CPAP) or bi-level positive airway pressure (Bi-PAP) treatment. RESULTS: The mean difference between PaCO(2) and PtcCO(2) was -1.4 mmHg, and the standard deviation of the difference was 1.3 mmHg. Bland-Altman analysis showed generally good agreement between the two methods with a 95% limit of agreement of -4 to 1.1. The agreement between methods did not significantly change before and during cPAP or Bi-PAP treatment in hypercapnic patients. CONCLUSIONS: The accuracy of estimation of PaCO(2) by transcutaneous monitoring was generally good in comparison with standard arterial blood gases examination. The device appears to be promising for use in obesepatients to evaluate abnormalities in their alveolar ventilation.
Authors: Pablo Rodriguez; François Lellouche; Jerome Aboab; Christian Brun Buisson; Laurent Brochard Journal: Intensive Care Med Date: 2006-01-31 Impact factor: 17.440
Authors: Alexander Dullenkopf; Stefano Di Bernardo; Felix Berger; Margrit Fasnacht; Andreas C Gerber; Markus Weiss Journal: Paediatr Anaesth Date: 2003-11 Impact factor: 2.556
Authors: Richard B Berry; Rohit Budhiraja; Daniel J Gottlieb; David Gozal; Conrad Iber; Vishesh K Kapur; Carole L Marcus; Reena Mehra; Sairam Parthasarathy; Stuart F Quan; Susan Redline; Kingman P Strohl; Sally L Davidson Ward; Michelle M Tangredi Journal: J Clin Sleep Med Date: 2012-10-15 Impact factor: 4.062
Authors: Joanna M Dion; Chris McKee; Joseph D Tobias; Daniel Herz; Paul Sohner; Steven Teich; Marc Michalsky Journal: J Clin Monit Comput Date: 2014-06-11 Impact factor: 2.502
Authors: Massimo Antonelli; Elie Azoulay; Marc Bonten; Jean Chastre; Giuseppe Citerio; Giorgio Conti; Daniel De Backer; François Lemaire; Herwig Gerlach; Johan Groeneveld; Goran Hedenstierna; Duncan Macrae; Jordi Mancebo; Salvatore M Maggiore; Alexandre Mebazaa; Philipp Metnitz; Jerôme Pugin; Jan Wernerman; Haibo Zhang Journal: Intensive Care Med Date: 2009-01-06 Impact factor: 17.440