Literature DB >> 11900043

Combining transcutaneous blood gas measurement and pulse oximetry.

Patrick Eberhard1, P A Gisiger, J P Gardaz, D R Spahn.   

Abstract

We are describing the preliminary results of tests performed in adult volunteers and in adult patients during and after general anesthesia with a miniaturized single sensor combining the continuous and non-invasive measurement of oxygen saturaiton by pulse oximetry (SpO2) and transcutaneous PCO2 (OxiCarbo sensor). The sensor is heated to 42 degrees C to arterialize the cutaneous tissue and is applied at the ear lobe with a special low-pressure clip. The results indicate a good agreement between ear lobe PCO2 and arterial PCO2 in the range 35 to 70 mmHg (10 patients, number of measurements 104, regression line TcPCO2 = 1.01 PaCO2 + 0.59 mmHg, bias 1.22 mmHg, SD 3.69 mmHg) and between ear lobe SpO2 and SaO2 (bias 0.44% with SD 0.77% in the range 80% to 100%, bias 1.39% with SD 1.43% in the range 60% to 80%). The ear lobe OxiCarbog sensor detects the SpO2 change 5 to 37 sec faster than a finger sensor and the PCO2 change 9 to 48 sec faster than a transcutaneous sensor fixed at the upper arm. Further improvements versus single sensors are a higher stability of the SpO2 signal and the possibility of performing long term SpO2 and PCO2 measurement at the ear lobe.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11900043

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  18 in total

1.  Capnographic monitoring for carbon dioxide insufflation during endoscopic submucosal dissection: comparison of transcutaneous and end-tidal capnometers [corrected].

Authors:  Ryusaku Kusunoki; Yuji Amano; Takafumi Yuki; Akihiko Oka; Mayumi Okada; Yasumasa Tada; Goichi Uno; Ichiro Moriyama; Norihisa Ishimura; Shunji Ishihara; Yoshikazu Kinoshita
Journal:  Surg Endosc       Date:  2011-09-22       Impact factor: 4.584

2.  Transcutaneous PCO2 monitors are more accurate than end-tidal PCO2 monitors.

Authors:  Makihiko Hirabayashi; Chieko Fujiwara; Norimasa Ohtani; Sohei Kagawa; Masayuki Kamide
Journal:  J Anesth       Date:  2009-05-15       Impact factor: 2.078

Review 3.  Guideline-oriented perioperative management of patients with bronchial asthma and chronic obstructive pulmonary disease.

Authors:  Michiaki Yamakage; Sohshi Iwasaki; Akiyoshi Namiki
Journal:  J Anesth       Date:  2008-11-15       Impact factor: 2.078

4.  Initial transcutaneous PCO2 overshoot with ear probe at 42 degrees C.

Authors:  Sohei Kagawa; Norimasa Otani; Masayuki Kamide; Pierre-Alain Gisiger; Patrick Eberhard; John W Severinghaus
Journal:  J Clin Monit Comput       Date:  2004-12       Impact factor: 2.502

Review 5.  Hemodynamic management of cardiovascular failure by using PCO(2) venous-arterial difference.

Authors:  Martin Dres; Xavier Monnet; Jean-Louis Teboul
Journal:  J Clin Monit Comput       Date:  2012-07-25       Impact factor: 2.502

6.  Transcutaneous arterial carbon dioxide pressure monitoring in critically ill adult patients.

Authors:  Pablo Rodriguez; François Lellouche; Jerome Aboab; Christian Brun Buisson; Laurent Brochard
Journal:  Intensive Care Med       Date:  2006-01-31       Impact factor: 17.440

7.  Dyspnoea associated with anxiety--symptomatic therapy with opioids in combination with lorazepam and its effect on ventilation in palliative care patients.

Authors:  Katri Elina Clemens; Eberhard Klaschik
Journal:  Support Care Cancer       Date:  2010-12-14       Impact factor: 3.603

8.  Evaluation of a transcutaneous carbon dioxide monitor in severe obesity.

Authors:  Mauro Maniscalco; Anna Zedda; Stanislao Faraone; Pierluigi Carratù; Matteo Sofia
Journal:  Intensive Care Med       Date:  2008-03-26       Impact factor: 17.440

9.  Use of oxygen and opioids in the palliation of dyspnoea in hypoxic and non-hypoxic palliative care patients: a prospective study.

Authors:  Katri Elina Clemens; Ines Quednau; Eberhard Klaschik
Journal:  Support Care Cancer       Date:  2008-08-22       Impact factor: 3.603

10.  Incidence and severity of respiratory insufficiency detected by transcutaneous carbon dioxide monitoring after cardiac surgery and intensive care unit discharge.

Authors:  Elaine E Lagow; Barbara Bobbi Leeper; Linda W Jennings; Michael A E Ramsay
Journal:  Proc (Bayl Univ Med Cent)       Date:  2013-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.