Literature DB >> 18338128

Stereotactic vacuum-assisted breast biopsy in 268 nonpalpable lesions.

M Tonegutti1, V Girardi.   

Abstract

PURPOSE: We evaluated the reliability of stereotactic vacuum-assisted breast biopsies (VAB) from our personal experience.
MATERIALS AND METHODS: Between January 2003 and December 2005, 268 patients underwent VAB with an 11-gauge probe at our institution. Inclusion criteria were nonpalpable lesions, undetectable by ultrasound and suspected at mammography (microcalcifications, circumscribed mass, architectural distortion), for which cytology and/or core biopsy could not provide a definite diagnosis. Lesion mammographic patterns were microcalcifications in 186 cases (77.5%), mostly localised clusters (130/186: 70%); circumscribed mass with or without microcalcifications in 36 cases (15%) and architectural distortion with or without microcalcifications in 18 cases (7.5%). On the basis of the Breast Imaging Reporting and Data System (BI-RADS) classification, 16 cases (7%) were graded as highly suspicious for malignancy (BI-RADS 5), 81 (34%) as suspicious for malignancy (BI-RADS 4b), 97 (40%) as indeterminate (BI-RADS 4a) and 46 (19%) as probably benign (BI-RADS 3). Lesion size was <or=10 mm in 161 cases (67%) and >20 mm in only 38 cases (16%), 30 of which appeared as microcalcifications.
RESULTS: In 28/268 lesions (10.5%) the biopsy could not be performed (nonidentification of the lesion; inaccessibility due to location or breast size). In 12/240 (5%) biopsies, the sample was not representative. Pathology revealed 100/240 (42%) malignant or borderline lesions and 140/240 (58%) benign lesions. Among the malignant lesions, 16/100 (16%) were invasive carcinoma [infiltrating ductal carcinoma (IDC) or infiltrating lobular carcinoma (ILC)], 13/100 (13%) were microinvasive (T1mic), 35/100 (35%) were ductal carcinoma in situ (DCIS), 9/100 (9%) were lobular carcinoma in situ (CLIS). Among the borderline lesions, 27/100 (27%) were atypical epithelial hyperplasia [atypical ductal hyperplasia (ADH) or atypical lobular hyperplasia (ALH)]. In 9/100 surgically treated lesions (9%), there was discordance between the microhistological findings of VAB and the pathological results of the surgical procedure: 8/9 were underestimated by VAB (four ADH vs. DCIS, three DCIS vs. IDC, one ADH vs. IDC), and 1/9 was overestimated (T1mic vs. DCIS). Complications following VAB occurred in 9/240 patients (3.7%).
CONCLUSIONS: In our experience, VAB showed fair reliability in the diagnosis of nonpalpable breast lesions despite a portion of failed (10.5%), nonsignificant (5%) procedures and underestimated lesions (9%).

Entities:  

Mesh:

Year:  2008        PMID: 18338128     DOI: 10.1007/s11547-008-0226-0

Source DB:  PubMed          Journal:  Radiol Med        ISSN: 0033-8362            Impact factor:   3.469


  36 in total

1.  Atypical ductal hyperplasia: histologic underestimation of carcinoma in tissue harvested from impalpable breast lesions using 11-gauge stereotactically guided directional vacuum-assisted biopsy.

Authors:  R F Brem; V S Behrndt; L Sanow; O M Gatewood
Journal:  AJR Am J Roentgenol       Date:  1999-05       Impact factor: 3.959

2.  BI-RADS categorization as a predictor of malignancy.

Authors:  S G Orel; N Kay; C Reynolds; D C Sullivan
Journal:  Radiology       Date:  1999-06       Impact factor: 11.105

3.  Stereotactic breast biopsy of atypical ductal hyperplasia and ductal carcinoma in situ lesions: improved accuracy with directional, vacuum-assisted biopsy.

Authors:  F Burbank
Journal:  Radiology       Date:  1997-03       Impact factor: 11.105

4.  Large-core needle biopsy of nonpalpable breast lesions.

Authors:  J E Meyer; D N Smith; S C Lester; C Kaelin; P J DiPiro; C M Denison; R L Christian; S C Harvey; D L Selland; S M Durfee
Journal:  JAMA       Date:  1999-05-05       Impact factor: 56.272

5.  Analysis of cancers not diagnosed at stereotactic core breast biopsy.

Authors:  L Liberman; D D Dershaw; J R Glassman; A F Abramson; E A Morris; L R LaTrenta; P P Rosen
Journal:  Radiology       Date:  1997-04       Impact factor: 11.105

6.  Comparison of rebiopsy rates after stereotactic core needle biopsy of the breast with 11-gauge vacuum suction probe versus 14-gauge needle and automatic gun.

Authors:  L E Philpotts; N A Shaheen; D Carter; R C Lange; C H Lee
Journal:  AJR Am J Roentgenol       Date:  1999-03       Impact factor: 3.959

7.  Atypical ductal hyperplasia: can some lesions be defined as probably benign after stereotactic 11-gauge vacuum-assisted biopsy, eliminating the recommendation for surgical excision?

Authors:  Roger J Jackman; Robyn L Birdwell; Debra M Ikeda
Journal:  Radiology       Date:  2002-08       Impact factor: 11.105

8.  Stereotactic vacuum-assisted breast biopsy in 2874 patients: a multicenter study.

Authors:  Ute Kettritz; Kerstin Rotter; Ingrid Schreer; Margarete Murauer; Rüdiger Schulz-Wendtland; Daniela Peter; Sylvia H Heywang-Köbrunner
Journal:  Cancer       Date:  2004-01-15       Impact factor: 6.860

9.  The breast imaging reporting and data system: positive predictive value of mammographic features and final assessment categories.

Authors:  L Liberman; A F Abramson; F B Squires; J R Glassman; E A Morris; D D Dershaw
Journal:  AJR Am J Roentgenol       Date:  1998-07       Impact factor: 3.959

10.  Calcification retrieval at stereotactic, 11-gauge, directional, vacuum-assisted breast biopsy.

Authors:  L Liberman; J H Smolkin; D D Dershaw; E A Morris; A F Abramson; P P Rosen
Journal:  Radiology       Date:  1998-07       Impact factor: 11.105

View more
  7 in total

1.  Mammotome(®) and EnCor (®): comparison of two systems for stereotactic vacuum-assisted core biopsy in the characterisation of suspicious mammographic microcalcifications alone.

Authors:  Giovanna Mariscotti; Manuela Durando; Mattia Robella; Francesca Angelino; Elisa Regini; Pier Paolo Campanino; Marco Belletti; Silvia Osano; Laura Bergamasco; Paolo Fonio; Giovanni Gandini
Journal:  Radiol Med       Date:  2014-08-15       Impact factor: 3.469

2.  BI-RADS categorisation of 2,708 consecutive nonpalpable breast lesions in patients referred to a dedicated breast care unit.

Authors:  A-S Hamy; S Giacchetti; M Albiter; C de Bazelaire; C Cuvier; F Perret; S Bonfils; P Charvériat; H Hocini; A de Roquancourt; M Espie
Journal:  Eur Radiol       Date:  2011-07-16       Impact factor: 5.315

3.  Vacuum-assisted biopsy diagnosis of atypical ductal hyperplasia and patient management.

Authors:  A Ancona; M Capodieci; A Galiano; F Mangieri; V Lorusso; G Gatta
Journal:  Radiol Med       Date:  2011-01-12       Impact factor: 3.469

4.  B3 breast lesions determined by vacuum-assisted biopsy: how to reduce the frequency of benign excision biopsies.

Authors:  M Tonegutti; V Girardi; S Ciatto; E Manfrin; F Bonetti
Journal:  Radiol Med       Date:  2010-09-17       Impact factor: 3.469

5.  Differential diagnosis between fibroadenoma, giant fibroadenoma and phyllodes tumour: sonographic features and core needle biopsy.

Authors:  G Gatta; F Iaselli; V Parlato; G Di Grezia; R Grassi; A Rotondo
Journal:  Radiol Med       Date:  2011-04-19       Impact factor: 3.469

6.  Role of axillary ultrasound in the preoperative diagnosis of lymph node metastases in patients affected by breast carcinoma.

Authors:  A Luparia; P Campanino; R Cotti; D Lucarelli; M Durando; G Mariscotti; G Gandini
Journal:  Radiol Med       Date:  2009-09-30       Impact factor: 3.469

7.  Diagnostic accuracy of tomosynthesis-guided vacuum assisted breast biopsy of ultrasound occult lesions.

Authors:  Suhaila Bohan; Marlina Tanty Ramli Hamid; Wai Yee Chan; Anushya Vijayananthan; Norlisah Ramli; Shaleen Kaur; Kartini Rahmat
Journal:  Sci Rep       Date:  2021-01-08       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.